Elmo Rietschle 2BH1014
Elmo Rietschle 2BH1014 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -40 mbar, Motor power 0.25 kW, Noise level 61 dB.
The 2BH1014 is a single-stage side-channel blower from Elmo Rietschle's G-BH1 series, driven by a 1~ AC motor with permanently connected run capacitor. It delivers up to 55 mbar differential pressure in vacuum or compressor mode at 60 Hz, positioning it between the 2BH1009 and 2BH1015 siblings. Its compact 11 kg frame and IP55 protection suit continuous-duty industrial vacuum or pressure generation in clean, non-corrosive gas streams.
Elmo Rietschle G-BH1 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Weight, kg | Max. differential pressure, mbar | Current, A | Protection rating |
|---|---|---|---|---|---|---|
| 2BH1014 Current | 0.32 | 57 | 11 | -55 | 3.2–6.5 | IP55 |
| 2BH1009 | — | — | — | — | — | — |
| 2BH1015 | 1.3 | 64 | 21 | -180 | 8–16 | IP55 |
| 2BH1023 | 1.75 | 69 | 69 | -190 | 10–20 | IP55 |
| 2BH1035 | 2.2 | 64 | 70 | -140 | 14.3–27 | IP55 |
| 2BH1100 | 0.2 | 53 | 10 | -120 | 1.39 Δ / 0.80 Y | IP 55 |
| 2BH1200 | 0.29 | 40 | 57 | -40 | 1.38 0.8 Y | IP55 |
| 2BH1300 | 0.29 | 100 | 51 | -100 | 1.9 | IP 55 |
| 2BH1310 | 0.7 | 56 | 16 | -250 | 3.8 Δ / 2.20 Y | IP55 |
| 2BH1330 | 0.29 | 80 | 51 | — | 1.74 Δ / 1.0 Y | IP55 |
| 2BH1400 | 0.95 | 61 | 16 | -180 | 5.6 | IP55 |
| 2BH1410 | 2 | 65 | 28 | -300 | 6.9 | IP55 |
| 2BH1430 | 1.1 | 64 | 16 | 110 | 4.2 | IP55 |
| 2BH1490 | 0.95 | 61 | 16 | -140 | 4.8 VV | IP55 |
| 2BH1500 | 0.95 | 65 | 21 | -90 | 4.2 | IP55 |
| 2BH1510 | 4 | 71 | 48 | -400 | 7.6–15.2 | IP55 |
| 2BH1530 | 1.6 | 69 | 25 | -90 | 4.7 | IP55 |
| 2BH1590 | 1.3 | 61 | 21 | -190 | 2.75 | IP55 |
| 2BH1600 | 1.75 | 72 | 31 | 130 | 9.9 | IP55 |
| 2BH1610 | 2.5 | 75 | 48 | 160 | 6 | IP55 |
| 2BH1630 | 2.5 | 64 | 36 | -160 | 17.1 | IP55 |
| 2BH1640 | 4.6 | 65 | 65 | -240–260 | 17.1 | IP55 |
| 2BH1690 | 2.5 | 64 | 34 | -200 | 9.9 | IP55 |
| 2BH1800 | 5.8 | 77 | 131 | 260 | 11–22 | IP55 |
| 2BH1810 | 9.9 | 74 | 188 | -460 | 30.8 | IP55 |
| 2BH1830 | 5.8 | 75 | 133 | -160 | 19.4 | IP55 |
| 2BH1900 | 8.6 | 71 | 183 | -190 | 30.8 | IP55 |
| 2BH1910 | 12.6 | 76 | 295 | -220 | 26.4 | IP55 |
| 2BH1930 | 8.6 | 75 | 212 | -80 | 17.6–35.2 | IP55 |
| 2BH1940 | 19.9 | 73 | 303 | -150 | 63.1 | IP55 |
| 2BH1943 | 17.3 | 77 | 330 | -160 | 72.2 UU / 36.1 U | IP55 |
Full specifications
| Max. differential pressure | -40 mbar (50 Hz) 60 Hz: -55 mbar |
| Motor power | 0.25 kW (50 Hz) 60 Hz: 0.32 kW |
| Noise level | 57 dB (50 Hz) 60 Hz: 61 dB |
| Max. Differenzdruck Verdichter (alt 50 Hz) mfr | 40 mbar (50 Hz) |
| Max. Differenzdruck Verdichter (alt 60 Hz) mfr | 55 mbar (60 Hz) |
| Weight | 11 kg (50 Hz) 60 Hz: 11 kg |
| Number of stages | 1 |
| Current | 6.5 / 3.2 A (50 Hz) 60 Hz: 5.9 / 3.0 A |
| Frequency | 50 Hz (50 Hz) 60 Hz: 60 Hz |
| Power supply | 1~ 50/60 Hz, IP55, Isolierstoffklasse F, Motor mit UL, mit angebautem Dauerbetriebskondensator |
| Voltage | 115 / 230 V (50 Hz) 60 Hz: 115 / 230 V |
| Protection rating | IP55 |
| Operating temperature | 25 degC |
Description
Construction and series positioning
- Single-stage side-channel (regenerative) blower with cast housing and integrated 1~ AC motor; no external drive or coupling required.
- Motor: 1~ 50/60 Hz, IP55, insulation class F, UL-recognized, with permanently connected run capacitor (Dauerbetriebskondensator).
- Delivered in two voltage variants: V4 (100/200 V) for 50 Hz and V5 (115/230 V) for 60 Hz; order codes BH1014-1AAA-AV4-BA0 and BH1014-1AAA-AV5-BA0 respectively.
- Within the G-BH1 series, the 2BH1014 sits between the smaller 2BH1009 and larger 2BH1015; it is the mid-range single-phase option before moving to higher-capacity or three-phase siblings such as 2BH1023 and 2BH1035.
Performance and operating behavior
- Maximum differential pressure: 40 mbar (50 Hz) and 55 mbar (60 Hz) in both vacuum and compressor modes; symmetrical capability allows use as either a vacuum pump or a low-pressure blower.
- Rated power: 0.32 kW at 50 Hz, 0.25 kW at 60 Hz; rated current: 5.9/3.0 A (50 Hz) and 6.5/3.2 A (60 Hz) at 115/230 V.
- Sound pressure level: 57 dB(A) at 50 Hz, 61 dB(A) at 60 Hz.
- No digitized curve points are available; for precise flow-pressure mapping, request the manufacturer's performance curve for the exact voltage variant.
Electrical and control specifics
- Voltage tolerance: ±5% for 1~ motors; frequency tolerance: ±2%.
- The run capacitor is factory-mounted and must remain in circuit during operation; no separate starting relay or capacitor is required.
- Motor is not inverter-rated per available documentation; speed control via variable frequency drive is not specified and should be confirmed with the manufacturer before use.
Installation and operation
- Weight approximately 11 kg; IP55 protection allows indoor use in dusty or damp environments, but the blower is not suitable for outdoor installation without additional protection.
- No specific installation orientation or piping connection details are provided in the available digest; refer to the full instruction manual for mounting position, inlet/outlet port sizes, and recommended filtration.
Integration & Operating Notes
Exceeding the ±5% voltage tolerance can cause motor overheating, reduced torque, or capacitor failure. Verify the actual supply voltage under load, especially on long cable runs or shared circuits, and use a voltage stabilizer if fluctuations are common.
Operating the blower outside the ±2% frequency band (e.g., on 50 Hz supply when 60 Hz is specified) will shift speed and thus pressure/flow performance, and may overload the motor. Ensure the supply frequency matches the order variant (V4 for 50 Hz, V5 for 60 Hz).
The permanently connected run capacitor is part of the motor circuit; removing or disconnecting it will prevent the motor from starting or cause overheating. Do not substitute with a different capacitance value; use only original spare parts.
The blower is rated for a maximum differential pressure of 40 mbar at 50 Hz and 55 mbar at 60 Hz in both vacuum and compressor modes. Exceeding this limit can cause motor overload, overheating, or mechanical damage. Install a pressure relief valve or monitor differential pressure in the system.
The IP55 rating protects against dust ingress and water jets, making the blower suitable for many industrial indoor settings. However, it is not intended for outdoor use or immersion. Ensure the mounting location allows free air circulation around the motor for cooling.
Selection & Integration Q&A
Choose the 2BH1014 when you need up to 55 mbar differential pressure at 60 Hz in a single-phase, 11 kg package. The 2BH1009 offers lower capacity; the 2BH1015 provides higher capacity but may be physically larger. Select based on required pressure/flow and available mounting space.
The 2BH1014 requires a 1~ AC supply of 115/230 V (V5 variant) or 100/200 V (V4 variant) at 50 or 60 Hz, with voltage tolerance ±5% and frequency tolerance ±2%. The motor includes a permanently connected run capacitor; no external starter is needed.
The motor is rated IP55, which protects against dust and water jets, but the blower is not designed for outdoor installation without additional enclosure. Avoid direct exposure to rain or standing water; ensure adequate ventilation and ambient temperature within motor limits.
No specific maintenance schedule is provided in the available digest; refer to the instruction manual for bearing inspection and filter cleaning intervals. Base delivery does not include inlet filters, silencers, or flexible connectors; these must be ordered separately as required for the application.