Elmo Rietschle 2BH1015
Elmo Rietschle 2BH1015 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -150 mbar, Motor power 1.1 kW, Noise level 64 dB.
The 2BH1015 is a single-stage side-channel blower in the G-BH1 series, driven by a single-phase 115/230 V motor rated 1.1 kW at 50 Hz and 1.3 kW at 60 Hz. It delivers up to 190 mbar in compressor mode and -150 mbar (50 Hz) or -180 mbar (60 Hz) in vacuum mode, positioning it between the smaller 2BH1009/2BH1014 and larger 2BH1023/2BH1035 siblings. Its IP55, class F motor makes it suited for continuous duty in industrial vacuum or pressure supply systems where moderate flow and pressure are required.
Elmo Rietschle G-BH1 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Weight, kg | Max. differential pressure, mbar | Current, A | Protection rating |
|---|---|---|---|---|---|---|
| 2BH1015 Current | 1.3 | 64 | 21 | -180 | 8–16 | IP55 |
| 2BH1009 | — | — | — | — | — | — |
| 2BH1014 | 0.32 | 57 | 11 | -55 | 3.2–6.5 | IP55 |
| 2BH1023 | 1.75 | 69 | 69 | -190 | 10–20 | IP55 |
| 2BH1035 | 2.2 | 64 | 70 | -140 | 14.3–27 | IP55 |
| 2BH1100 | 0.2 | 53 | 10 | -120 | 1.39 Δ / 0.80 Y | IP 55 |
| 2BH1200 | 0.29 | 40 | 57 | -40 | 1.38 0.8 Y | IP55 |
| 2BH1300 | 0.29 | 100 | 51 | -100 | 1.9 | IP 55 |
| 2BH1310 | 0.7 | 56 | 16 | -250 | 3.8 Δ / 2.20 Y | IP55 |
| 2BH1330 | 0.29 | 80 | 51 | — | 1.74 Δ / 1.0 Y | IP55 |
| 2BH1400 | 0.95 | 61 | 16 | -180 | 5.6 | IP55 |
| 2BH1410 | 2 | 65 | 28 | -300 | 6.9 | IP55 |
| 2BH1430 | 1.1 | 64 | 16 | 110 | 4.2 | IP55 |
| 2BH1490 | 0.95 | 61 | 16 | -140 | 4.8 VV | IP55 |
| 2BH1500 | 0.95 | 65 | 21 | -90 | 4.2 | IP55 |
| 2BH1510 | 4 | 71 | 48 | -400 | 7.6–15.2 | IP55 |
| 2BH1530 | 1.6 | 69 | 25 | -90 | 4.7 | IP55 |
| 2BH1590 | 1.3 | 61 | 21 | -190 | 2.75 | IP55 |
| 2BH1600 | 1.75 | 72 | 31 | 130 | 9.9 | IP55 |
| 2BH1610 | 2.5 | 75 | 48 | 160 | 6 | IP55 |
| 2BH1630 | 2.5 | 64 | 36 | -160 | 17.1 | IP55 |
| 2BH1640 | 4.6 | 65 | 65 | -240–260 | 17.1 | IP55 |
| 2BH1690 | 2.5 | 64 | 34 | -200 | 9.9 | IP55 |
| 2BH1800 | 5.8 | 77 | 131 | 260 | 11–22 | IP55 |
| 2BH1810 | 9.9 | 74 | 188 | -460 | 30.8 | IP55 |
| 2BH1830 | 5.8 | 75 | 133 | -160 | 19.4 | IP55 |
| 2BH1900 | 8.6 | 71 | 183 | -190 | 30.8 | IP55 |
| 2BH1910 | 12.6 | 76 | 295 | -220 | 26.4 | IP55 |
| 2BH1930 | 8.6 | 75 | 212 | -80 | 17.6–35.2 | IP55 |
| 2BH1940 | 19.9 | 73 | 303 | -150 | 63.1 | IP55 |
| 2BH1943 | 17.3 | 77 | 330 | -160 | 72.2 UU / 36.1 U | IP55 |
Full specifications
| Max. differential pressure | -150 mbar (50 Hz) 60 Hz: -180 mbar |
| Motor power | 1.1 kW (50 Hz) 60 Hz: 1.3 kW |
| Noise level | 61 dB (50 Hz) 60 Hz: 64 dB |
| Max. Differenzdruck Vakuum mfr | -150 mbar (50 Hz) |
| Max. Differenzdruck Verdichter mfr | 190 mbar (50 Hz) |
| Max. Differenzdruck Vakuum mfr | -180 mbar (60 Hz) |
| Max. Differenzdruck Verdichter mfr | 190 mbar (60 Hz) |
| Bestell-Nr. mfr | BH1015-1AAA-FV5-BA0 (50 Hz) |
| Bestell-Nr. mfr | BH1015-1AAA-FV4-BA0 (60 Hz) |
| Max. differential pressure vacuum mfr | -180 mbar (60 Hz) |
| Max. differential pressure compressor mfr | 190 mbar (50 Hz) |
| Max. differential pressure compressor mfr | 190 mbar (60 Hz) |
| Order number mfr | BH1015-1AAA-FV5-BA0 (50 Hz) |
| Order number mfr | BH1015-1AAA-FV4-BA0 (60 Hz) |
| Max. Differenzdruck Verdichter (alt 50 Hz) mfr | 190 mbar (50 Hz) |
| Max. Differenzdruck Verdichter (alt 60 Hz) mfr | 190 mbar (60 Hz) |
| Weight | 21 kg (50 Hz) 60 Hz: 21 kg |
| Number of stages | 1 |
| Current | 17.0 / 8.0 A (50 Hz) 60 Hz: 16.0 / 8.0 A |
| Frequency | 50 Hz (50 Hz) 60 Hz: 60 Hz |
| Power supply | 1~ 50/60 Hz |
| Voltage | 115 / 230 V (50 Hz) 60 Hz: 115 / 230 V |
| Bemessungsstrom mfr | 16.0 / 8.0 A (50 Hz) |
| Bemessungsstrom mfr | 17.0 A (60 Hz) |
| Bemessungsleistung mfr | 1.1 kW (50 Hz) |
| Bemessungsleistung mfr | 1.3 kW (60 Hz) |
| Rated frequency mfr | 60 Hz (60 Hz) |
| Rated current mfr | 16.0 / 8.0 A (60 Hz) |
| Rated power mfr | 1.3 kW (60 Hz) |
| Protection rating | IP55 |
| Operating temperature | 25 degC |
| Schalldruckpegel mfr | 61 dB(A) (50 Hz) |
| Schalldruckpegel mfr | 64 dB(A) (60 Hz) |
| Sound pressure level mfr | 61 dB(A) (50 Hz) |
| Sound pressure level mfr | 64 dB(A) (60 Hz) |
Description
Construction and series positioning
- Single-stage side-channel (regenerative) blower with a single-phase AC motor; no three-phase option is indicated for this model code.
- Ordering codes BH1015-1AAA-FV5-BA0 (50 Hz) and BH1015-1AAA-FV4-BA0 (60 Hz) distinguish frequency-specific builds.
- Within the G-BH1 series, the 2BH1015 sits above the 2BH1009 and 2BH1014 and below the 2BH1023 and 2BH1035, offering a middle ground in pressure and flow capability.
- Motor is rated IP55 and insulation class F, allowing operation in dusty or damp industrial environments.
Performance behaviour
- Maximum differential pressure in compressor mode is 190 mbar at both 50 and 60 Hz.
- Maximum vacuum is -150 mbar at 50 Hz and -180 mbar at 60 Hz, reflecting the higher speed at 60 Hz.
- Sound pressure level is 61 dB(A) at 50 Hz and 64 dB(A) at 60 Hz, measured at standard conditions.
- Weight is approximately 21 kg for both frequency variants.
- No digitized curve points are available; performance beyond the maximum pressure values must be derived from the technical datasheet or requested from the manufacturer.
Electrical and control
- Voltage variants are 115/230 V at 50 Hz and 60 Hz; rated current is 16.0/8.0 A at 50 Hz and 17.0 A at 60 Hz.
- Rated power is 1.1 kW at 50 Hz and 1.3 kW at 60 Hz.
- The motor is single-phase; starting current and required protection must be sized according to the datasheet and local regulations.
- No integrated control or VFD is indicated; operation is via direct-on-line starting or an external contactor/overload relay.
Installation and operation
- The blower is air-cooled and must be mounted with sufficient clearance for ventilation.
- Inlet and outlet connections should be matched to the application; use of flexible connectors is recommended to avoid transmitting vibration.
- The IP55 rating permits outdoor installation with additional protection against direct water jets.
- No specific maintenance intervals are provided in the available digest; refer to the full instruction manual for service schedules.
Integration & Operating Notes
Operating above the maximum differential pressure of 190 mbar may cause overheating, increased noise, and reduced bearing life. For vacuum duty, the limit is -150 mbar at 50 Hz and -180 mbar at 60 Hz. Use a pressure relief valve or control loop to stay within these limits.
The motor is air-cooled and relies on free airflow around the housing. Install the blower with at least 100 mm clearance on all sides and avoid recirculation of hot air. In enclosed cabinets, forced ventilation may be required.
Dust and debris can accumulate on the impeller and in the inlet, reducing performance and causing imbalance. The service interval depends on the process air cleanliness; in dusty environments, weekly inspection is advised. Refer to the instruction manual for detailed cleaning procedures.
Selection & Integration Q&A
Choose the 2BH1015 when you need up to 190 mbar compressor pressure or -180 mbar vacuum (60 Hz) with a single-phase 1.1–1.3 kW motor. The 2BH1014 offers lower pressure/flow, while the 2BH1023 provides higher capacity but may require three-phase power. Select based on required pressure, flow, and available power supply.
The motor requires a single-phase 115 V or 230 V supply at 50 or 60 Hz. Use a dedicated circuit with a thermal overload relay set to the rated current (16.0 A at 115 V, 8.0 A at 230 V, 50 Hz; 17.0 A at 60 Hz). Ensure the supply can handle the starting current, which may be several times the rated current.
Mount the blower on a flat, vibration-free surface with sufficient clearance for air cooling. The IP55 motor allows operation in dusty and damp environments but not immersion. Ambient temperature limits are not specified in the digest; refer to the full manual. Avoid recirculation of hot air and ensure the inlet is protected from debris.
The base delivery includes the blower only. Accessories such as inlet filters, silencers, flexible connectors, and mounting feet must be ordered separately. Maintenance items include replacement air filters (if used) and periodic cleaning of the impeller. No specific spare parts kit is listed; consult the manufacturer for recommended spares.