Elmo Rietschle 2BH1023
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH1023

Elmo Rietschle 2BH1023 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -190 mbar, Motor power 1.75 kW, Noise level 70 dB.

The 2BH1023 is a single-stage side-channel blower from Elmo Rietschle's G-BH1 series, driven by a single-phase 115/230 V motor rated 1.75 kW at 50 Hz and 1.5 kW at 60 Hz. It delivers up to 200 mbar differential pressure in compressor mode and -190 mbar in vacuum mode at 50 Hz, positioning it above the 2BH1009/1014/1015 siblings but below the 2BH1035. Its IP55, Class F motor and 31 kg frame make it suited for continuous-duty pressure or vacuum supply in industrial processes.

Max. differential pressure
-190 mbar
Motor power
1.75 kW
Noise level
70 dB
Weight
69 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1023 Current 1.756969-19010–20IP55
2BH1009 ——————
2BH1014 0.325711-553.2–6.5IP55
2BH1015 1.36421-1808–16IP55
2BH1035 2.26470-14014.3–27IP55
2BH1100 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1300 0.2910051-1001.9IP 55
2BH1310 0.75616-2503.8 Δ / 2.20 YIP55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1400 0.956116-1805.6IP55
2BH1410 26528-3006.9IP55
2BH1430 1.164161104.2IP55
2BH1490 0.956116-1404.8 VVIP55
2BH1500 0.956521-904.2IP55
2BH1510 47148-4007.6–15.2IP55
2BH1530 1.66925-904.7IP55
2BH1590 1.36121-1902.75IP55
2BH1600 1.7572311309.9IP55
2BH1610 2.575481606IP55
2BH1630 2.56436-16017.1IP55
2BH1640 4.66565-240–26017.1IP55
2BH1690 2.56434-2009.9IP55
2BH1800 5.87713126011–22IP55
2BH1810 9.974188-46030.8IP55
2BH1830 5.875133-16019.4IP55
2BH1900 8.671183-19030.8IP55
2BH1910 12.676295-22026.4IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1940 19.973303-15063.1IP55
2BH1943 17.377330-16072.2 UU / 36.1 UIP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -190 mbar (50 Hz)
60 Hz: -180 mbar
Motor power 1.5 kW (50 Hz)
60 Hz: 1.75 kW
Noise level 69 dB (50 Hz)
60 Hz: 70 dB
Max. differential pressure compressor mfr 200 mbar (50 Hz)
Max. differential pressure vacuum mfr -180 mbar (60 Hz)
Max. differential pressure compressor mfr 180 mbar (60 Hz)
Order number mfr BH1023-1AAA-HV4-BA0 (50 Hz)
Order number mfr BH1023-1AAA-HV4-BA0 (60 Hz)
Max. Differenzdruck Verdichter (alt 50 Hz) mfr 200 mbar (50 Hz)
Max. Differenzdruck Verdichter (alt 60 Hz) mfr 180 mbar (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 69 kg (50 Hz)
60 Hz: 70 kg
Number of stages 1
Weight approx. mfr 31 kg
Electrical, Power & Drive Specifications
Current 19.0 / 9.5 A (50 Hz)
60 Hz: 20.0 / 10.0 A
Frequency 50 Hz (50 Hz)
60 Hz: 60 Hz
Voltage 115 / 230 V (50 Hz)
60 Hz: 115 / 230 V
Rated current mfr 20.0 / 10.0 A (60 Hz)
Rated power mfr 1.75 kW (60 Hz)
Voltage tolerance mfr ±5 % (1~ motors)
Operating Conditions, Environment & Protection
Protection rating IP55
Cooling type F
Operating temperature 25 degC
Sound pressure level mfr 69 dB(A) (50 Hz)
Sound pressure level mfr 70 dB(A) (60 Hz)

Description

Construction and series positioning

Performance behaviour

Installation and operation

Integration & Operating Notes

Electrical
Supply voltage must stay within ±5 % of nominal

The single-phase motor is wound for 115 V or 230 V at 50/60 Hz with a ±5 % tolerance. Exceeding this range risks overheating and reduced insulation life; a stabilised supply or buck-boost transformer should be considered where grid variation is common.

Technical Data Sheet — G-BH1 2BH1023 compressor (EN)
Process Limits
Do not exceed 200 mbar pressure or -190 mbar vacuum at 50 Hz

These are the maximum differential pressures for this model at 50 Hz; at 60 Hz the limits reduce to 180 mbar in both modes. Operating beyond them raises motor load and temperature, and the available data does not define behaviour outside these limits.

Technical Data Sheet — G-BH1 2BH1023 compressor (EN)
Mounting
31 kg single-phase unit requires rigid, level mounting

The blower should be bolted to a flat, rigid surface to avoid frame distortion and excess vibration. Because the motor is single-phase, vibration and torque pulsation are higher than for three-phase drives; flexible mounts or a resilient base can reduce transmission to the pipework.

Technical Data Sheet — G-BH1 2BH1023 compressor (EN)
Maintenance
No consumables or accessories are included in base delivery

The datasheet lists only the blower and motor; inlet filters, silencers, flexible connectors and mounting feet must be ordered separately. Periodic inspection should cover motor bearings, impeller clearance and housing fasteners, but no specific service interval is stated in the available documentation.

Technical Data Sheet — G-BH1 2BH1023 compressor (EN)

Selection & Integration Q&A

When should I choose the 2BH1023 instead of the 2BH1009, 2BH1014, 2BH1015 or 2BH1035?

Pick the 2BH1023 when you need up to 200 mbar pressure or -190 mbar vacuum at 50 Hz from a single-phase 115/230 V supply. The 1009/1014/1015 are smaller and lower-pressure; the 2BH1035 is larger and higher-capacity. Choose this model for mid-range duty where the 1035 would be oversized.

What supply and protection equipment does the single-phase 2BH1023 require?

A 115 V or 230 V single-phase supply within ±5 %, capable of at least 19.0 A at 115 V (9.5 A at 230 V) at 50 Hz, or 20.0 A at 115 V (10.0 A at 230 V) at 60 Hz. Use motor protection rated for the starting current, and ensure the circuit can handle the locked-rotor surge of a 1.75 kW single-phase motor.

What are the mounting and ambient limits for this blower?

Mount horizontally on a rigid, level base; the 31 kg mass and single-phase vibration call for secure bolting and possibly flexible mounts. The datasheet gives IP55 and Class F insulation but no ambient temperature range, so site conditions should be confirmed with the manufacturer.

What maintenance and accessories are needed that are not in the base delivery?

The base delivery is the blower only; inlet filters, silencers, flexible connectors and mounting feet are separate. No service interval is specified in the datasheet, so bearing and impeller inspection should be scheduled per site experience, with particular attention to the single-phase motor's start capacitor if fitted.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — G-BH1 2BH1023 compressor (EN)
Datasheet ·197,3 КБ ·2 pp.