Elmo Rietschle 2BH1600
Elmo Rietschle 2BH1600 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure 330 mbar, Motor power 1.75 kW, Noise level 64 dB.
The 2BH1600 is a side-channel blower from the Elmo Rietschle G-BH1 series, driven by a 1.75 kW (50 Hz) / 2.00 kW (60 Hz) IE3 motor with IP55 protection. It delivers a maximum differential pressure of 120 mbar in pressure mode and -130 mbar in vacuum mode at 50 Hz, with a sound pressure level of 63 dB(A). This model is positioned as a mid-range unit in the series, suitable for continuous duty in pneumatic conveying, vacuum lifting, or aeration processes where moderate pressure and vacuum are required.
Elmo Rietschle G-BH1 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Weight, kg | Max. differential pressure, mbar | Current, A | Protection rating |
|---|---|---|---|---|---|---|
| 2BH1600 Current | 1.75 | 72 | 31 | 130 | 9.9 | IP55 |
| 2BH1009 | — | — | — | — | — | — |
| 2BH1014 | 0.32 | 57 | 11 | -55 | 3.2–6.5 | IP55 |
| 2BH1015 | 1.3 | 64 | 21 | -180 | 8–16 | IP55 |
| 2BH1023 | 1.75 | 69 | 69 | -190 | 10–20 | IP55 |
| 2BH1035 | 2.2 | 64 | 70 | -140 | 14.3–27 | IP55 |
| 2BH1100 | 0.2 | 53 | 10 | -120 | 1.39 Δ / 0.80 Y | IP 55 |
| 2BH1200 | 0.29 | 40 | 57 | -40 | 1.38 0.8 Y | IP55 |
| 2BH1300 | 0.29 | 100 | 51 | -100 | 1.9 | IP 55 |
| 2BH1310 | 0.7 | 56 | 16 | -250 | 3.8 Δ / 2.20 Y | IP55 |
| 2BH1330 | 0.29 | 80 | 51 | — | 1.74 Δ / 1.0 Y | IP55 |
| 2BH1400 | 0.95 | 61 | 16 | -180 | 5.6 | IP55 |
| 2BH1410 | 2 | 65 | 28 | -300 | 6.9 | IP55 |
| 2BH1430 | 1.1 | 64 | 16 | 110 | 4.2 | IP55 |
| 2BH1490 | 0.95 | 61 | 16 | -140 | 4.8 VV | IP55 |
| 2BH1500 | 0.95 | 65 | 21 | -90 | 4.2 | IP55 |
| 2BH1510 | 4 | 71 | 48 | -400 | 7.6–15.2 | IP55 |
| 2BH1530 | 1.6 | 69 | 25 | -90 | 4.7 | IP55 |
| 2BH1590 | 1.3 | 61 | 21 | -190 | 2.75 | IP55 |
| 2BH1610 | 2.5 | 75 | 48 | 160 | 6 | IP55 |
| 2BH1630 | 2.5 | 64 | 36 | -160 | 17.1 | IP55 |
| 2BH1640 | 4.6 | 65 | 65 | -240–260 | 17.1 | IP55 |
| 2BH1690 | 2.5 | 64 | 34 | -200 | 9.9 | IP55 |
| 2BH1800 | 5.8 | 77 | 131 | 260 | 11–22 | IP55 |
| 2BH1810 | 9.9 | 74 | 188 | -460 | 30.8 | IP55 |
| 2BH1830 | 5.8 | 75 | 133 | -160 | 19.4 | IP55 |
| 2BH1900 | 8.6 | 71 | 183 | -190 | 30.8 | IP55 |
| 2BH1910 | 12.6 | 76 | 295 | -220 | 26.4 | IP55 |
| 2BH1930 | 8.6 | 75 | 212 | -80 | 17.6–35.2 | IP55 |
| 2BH1940 | 19.9 | 73 | 303 | -150 | 63.1 | IP55 |
| 2BH1943 | 17.3 | 77 | 330 | -160 | 72.2 UU / 36.1 U | IP55 |
Full specifications
| Max. differential pressure | 130 mbar (50 Hz, size 1) 60 Hz, size 1: 110 mbar · 50 Hz, size 2: 200 mbar · 60 Hz, size 2: 190 mbar · 50 Hz, size 3: 280 mbar · 60 Hz, size 3: 270 mbar · 50 Hz, size 4: 290 mbar · 60 Hz, size 4: 330 mbar |
| Motor power | 1.75 kW (50 Hz, size 1) 60 Hz, size 1: 2.00 kW · 50 Hz, size 2: 2.50 kW · 60 Hz, size 2: 3.00 kW · 50 Hz, size 3: 3.45 kW · 60 Hz, size 3: 4.0 kW · 50 Hz, size 4: 4.6 kW · 60 Hz, size 4: 5.3 kW |
| Noise level | 69 dB(A) (50 Hz, size 1) 60 Hz, size 1: 72 dB(A) · 50 Hz, size 2: 64 dB(A) · 60 Hz, size 2: 70 dB(A) · 50 Hz, size 3: 71 dB(A) · 60 Hz, size 3: 74 dB(A) · 50 Hz, size 4: 69 dB(A) · 60 Hz, size 4: 71 dB(A) |
| Max. differential pressure vacuum mfr | -130 mbar (50 Hz) |
| Max. differential pressure vacuum mfr | -110 mbar (60 Hz) |
| Product type mfr | Side channel blower with IE3-motors |
| Vacuum mfr | -130 mbar (50 Hz) |
| Vacuum mfr | -110 mbar (60 Hz) |
| Order No. mfr | 2BH1600-0AK01 |
| Approval mfr | UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate |
| Weight | 31 kg (size 1) size 2: 34 kg · size 3: 38 kg · size 4: 55 kg |
| Current | 6.9 A (50 Hz, delta, size 1) 60 Hz, size 1: 7.8 YY / 3.9 Y A · 60 Hz, NEMA, size 1: 7.8 A · 50 Hz, delta, size 2: 9.9 A · 60 Hz, size 2: 12.0 YY / 6.0 Y A · 60 Hz, NEMA, size 2: 12.0 YY A · 50 Hz, delta, size 3: 13.3 A · 60 Hz, size 3: 15.2 YY / 7.6 Y A · 60 Hz, NEMA, size 3: 15.2 YY A · 50 Hz, delta/YY, size 4: 17.1 / 9.9 A · 60 Hz, size 4: 19.6 YY / 9.8 Y A · 60 Hz, NEMA, size 4: 19.6 YY A |
| Frequency | 50 Hz |
| Power supply | 3~ 50/60 Hz |
| Voltage | 190-210 V (50 Hz, delta, size 1) 60 Hz, size 1: 190-210 YY / 380-420 Y V · 60 Hz, NEMA, size 1: 200 V · 50 Hz, delta, size 2: 190-210 V · 60 Hz, size 2: 190-210 YY / 380-420 Y V · 60 Hz, NEMA, size 2: 200 YY V · 50 Hz, delta, size 3: 190-210 V · 60 Hz, size 3: 190-210 YY / 380-420 Y V · 60 Hz, NEMA, size 3: 200 YY V · 50 Hz, delta/YY, size 4: 190-210 / 380-420 V · 60 Hz, size 4: 190-210 YY / 380-420 Y V · 60 Hz, NEMA, size 4: 200 YY V |
| Efficiency class mfr | IE3 (50 Hz) |
| Efficiency class mfr | NP (60 Hz) |
| Rated current mfr | 7.8 A (60 Hz) |
| Frequency (alt var) mfr | 60 Hz |
| Protection rating | IP55 |
| Operating temperature | 25 degC (max) |
| Sound pressure level mfr | 69 dB(A) (50 Hz) |
| Sound pressure level mfr | 72 dB(A) (60 Hz) |
Description
Construction and positioning
- The 2BH1600 is a regenerative (side-channel) blower with a dynamically balanced impeller running in a close-tolerance housing, directly coupled to a three-phase asynchronous motor.
- Within the G-BH1 series, it sits between the smaller 2BH10xx models (e.g., 2BH1009, 2BH1014) and larger variants, offering higher pressure and flow capacity than the lower-numbered siblings.
- The motor is designed for dual frequency (50/60 Hz) and dual voltage (220-240 Δ / 380-420 Y at 50 Hz; 440-480 Y at 60 Hz), with IE3 efficiency class and IP55 protection, making it suitable for industrial environments.
Performance behavior
- At 50 Hz, the unit achieves a maximum differential pressure of 130 mbar (size 1); at 60 Hz, the corresponding value is 110 mbar (size 1).
- The sound pressure level is 69 dB(A) at 50 Hz and 72 dB(A) at 60 Hz (size 1), measured at a distance of 1 m (per standard practice).
- The blower is capable of continuous operation, but the actual operating point should be selected to avoid surge or overload conditions, especially when operating near the maximum pressure limits.
Installation and operation
- The motor is foot-mounted (IM B3) and requires rigid, flat mounting to minimize vibration. Ensure sufficient clearance for cooling air intake and exhaust.
- Electrical connection must be made according to the terminal box diagram for the selected voltage and frequency. The motor is equipped with thermal protection (PTC or bi-metal) that should be connected to the control system.
- The blower can be used in either pressure or vacuum mode by connecting the piping to the appropriate port. Use flexible connectors to isolate vibration and prevent stress on the housing.
- Regular maintenance includes checking the impeller for debris, verifying coupling alignment (if applicable), and inspecting the motor bearings. The manual specifies maintenance intervals based on operating hours.
Integration & Operating Notes
The motor is designed for 220-240 V delta or 380-420 V star at 50 Hz, and 440-480 V star at 60 Hz. Incorrect terminal linking will cause motor failure. Verify the supply voltage and frequency before connecting, and ensure the terminal box links match the nameplate diagram. Use a motor protection switch set to the rated current for the selected connection: at 50 Hz, 6.9 A (delta, size 1); at 60 Hz, 7.8 A (NEMA, size 1) or 7.8 YY / 3.9 Y A (size 1).
Selection & Integration Q&A
Choose the 2BH1600 when your process requires higher pressure (up to 130 mbar at 50 Hz, size 1) than the smaller models can provide. The 2BH1600 also offers a higher power rating (1.75 kW at 50 Hz, size 1) for increased flow capacity. If your duty point is well within the capabilities of the 2BH1014 or 2BH1015, those may be more energy-efficient and cost-effective.
The motor requires a three-phase supply matching the nameplate voltage (e.g., 400 V star at 50 Hz). Use a motor protection switch set to the rated current for the selected connection: at 50 Hz, 6.9 A (delta, size 1); at 60 Hz, 7.8 A (NEMA, size 1) or 7.8 YY / 3.9 Y A (size 1). The motor has PTC thermistors that must be connected to a tripping unit or control system to prevent overheating. Ensure the supply can handle the starting current, which may be 6-8 times the rated current.
The standard motor is designed for ambient temperatures up to 40°C. For higher temperatures, derating may be required. The blower is suitable for continuous duty (S1), but the actual operating point should be within the specified pressure limits. Ensure adequate ventilation to prevent overheating, especially when installed in enclosures.
The base delivery includes the blower only. Flexible connectors, inlet/outlet silencers, filters, and a motor protection switch are not included and must be ordered separately. For maintenance, keep spare impeller, bearings, and gaskets on hand. Refer to the spare parts list in the manual for part numbers.