Elmo Rietschle 2BH1640
Elmo Rietschle 2BH1640 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -270…300 mbar, Motor power 4.6 kW, Noise level 87 dB.
The 2BH1640 is a side-channel (regenerative) blower from Elmo Rietschle's G-BH1 series, built with an IE3 premium-efficiency 3-phase motor rated 7.3 kW at 50 Hz and 9.9 kW at 60 Hz, protected to IP55 with class F insulation. It delivers a maximum vacuum of -210 mbar at 50 Hz (-270 mbar at 60 Hz) and a maximum positive pressure of 200 mbar at 50 Hz (300 mbar at 60 Hz), making it the largest frame in the G-BH1 range shown here. Its primary role is to provide oil-free, contactless vacuum or pressure for pneumatic conveying, drying, and aeration duties where moderate differential pressures and continuous duty are required.
Elmo Rietschle G-BH1 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Weight, kg | Max. differential pressure, mbar | Current, A | Protection rating |
|---|---|---|---|---|---|---|
| 2BH1640 Current | 4.6 | 65 | 65 | -240–260 | 17.1 | IP55 |
| 2BH1009 | — | — | — | — | — | — |
| 2BH1014 | 0.32 | 57 | 11 | -55 | 3.2–6.5 | IP55 |
| 2BH1015 | 1.3 | 64 | 21 | -180 | 8–16 | IP55 |
| 2BH1023 | 1.75 | 69 | 69 | -190 | 10–20 | IP55 |
| 2BH1035 | 2.2 | 64 | 70 | -140 | 14.3–27 | IP55 |
| 2BH1100 | 0.2 | 53 | 10 | -120 | 1.39 Δ / 0.80 Y | IP 55 |
| 2BH1200 | 0.29 | 40 | 57 | -40 | 1.38 0.8 Y | IP55 |
| 2BH1300 | 0.29 | 100 | 51 | -100 | 1.9 | IP 55 |
| 2BH1310 | 0.7 | 56 | 16 | -250 | 3.8 Δ / 2.20 Y | IP55 |
| 2BH1330 | 0.29 | 80 | 51 | — | 1.74 Δ / 1.0 Y | IP55 |
| 2BH1400 | 0.95 | 61 | 16 | -180 | 5.6 | IP55 |
| 2BH1410 | 2 | 65 | 28 | -300 | 6.9 | IP55 |
| 2BH1430 | 1.1 | 64 | 16 | 110 | 4.2 | IP55 |
| 2BH1490 | 0.95 | 61 | 16 | -140 | 4.8 VV | IP55 |
| 2BH1500 | 0.95 | 65 | 21 | -90 | 4.2 | IP55 |
| 2BH1510 | 4 | 71 | 48 | -400 | 7.6–15.2 | IP55 |
| 2BH1530 | 1.6 | 69 | 25 | -90 | 4.7 | IP55 |
| 2BH1590 | 1.3 | 61 | 21 | -190 | 2.75 | IP55 |
| 2BH1600 | 1.75 | 72 | 31 | 130 | 9.9 | IP55 |
| 2BH1610 | 2.5 | 75 | 48 | 160 | 6 | IP55 |
| 2BH1630 | 2.5 | 64 | 36 | -160 | 17.1 | IP55 |
| 2BH1690 | 2.5 | 64 | 34 | -200 | 9.9 | IP55 |
| 2BH1800 | 5.8 | 77 | 131 | 260 | 11–22 | IP55 |
| 2BH1810 | 9.9 | 74 | 188 | -460 | 30.8 | IP55 |
| 2BH1830 | 5.8 | 75 | 133 | -160 | 19.4 | IP55 |
| 2BH1900 | 8.6 | 71 | 183 | -190 | 30.8 | IP55 |
| 2BH1910 | 12.6 | 76 | 295 | -220 | 26.4 | IP55 |
| 2BH1930 | 8.6 | 75 | 212 | -80 | 17.6–35.2 | IP55 |
| 2BH1940 | 19.9 | 73 | 303 | -150 | 63.1 | IP55 |
| 2BH1943 | 17.3 | 77 | 330 | -160 | 72.2 UU / 36.1 U | IP55 |
Full specifications
| Max. differential pressure | -180 / 160 mbar (50 Hz, size 1) 50 Hz, size 2: -240 / 260 mbar · 50 Hz, size 3: -240 / 320 mbar · 60 Hz, size 1: -130 / 120 mbar · 60 Hz, size 2: -210 / 200 mbar · 60 Hz, size 3: -270 / 300 mbar |
| Motor power | 4.6 kW (50 Hz, 190-210 V D, size 1) 60 Hz, 200 V, size 1: 5.3 kW · 50 Hz, 190-210 V D, size 2: 6.3 kW · 60 Hz, size 2: 7.3 kW · 50 Hz, 190-210 V D, size 3: 8.6 kW · 60 Hz, size 3: 9.9 kW |
| Noise level | 65 dB(A) (size 1) size 2: 75 dB(A) · size 3: 87 dB(A) |
| Max. differential pressure vacuum mfr | -240 mbar (50 Hz) |
| Max. differential pressure vacuum mfr | -270 mbar (60 Hz) |
| Order No. mfr | 2BH1640-1GQ47 |
| Series mfr | 2BH1 640 |
| Product type mfr | Side channel blower with IE3-motors |
| Motor protection category mfr | IP55 |
| Approvals mfr | UL and CSA approved |
| Certification mfr | UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate |
| Order No. mfr | 2BH1640-1GK56 (50 Hz) |
| Order No. mfr | 2BH1640-1GK56 (60 Hz) |
| Max. differential pressure vacuum mfr | -210 mbar (60 Hz NEMA) |
| Weight | 65 kg (size 1) size 2: 75 kg · size 3: 87 kg |
| Weight approx. mfr | 75 kg |
| Weight approx. mfr | 87 kg (50 Hz) |
| Weight approx. mfr | 87 kg (60 Hz) |
| Current | 17.1 A (50 Hz, 190-210 V D, size 1) 60 Hz, 200 V, size 1: 19.6 A · 50 Hz, 190-210 V D, size 2: 23.5 A · 60 Hz, 190-210 V / 380-420 V, size 2: 27.6 A · 50 Hz, 190-210 V D, size 3: 30.8 A · 60 Hz, 190-210 V / 380-420 V, size 3: 35.2 A |
| Frequency | 50 Hz (50 Hz) 60 Hz: 60 Hz |
| Power supply | 3~ 50/60 Hz |
| Voltage | 190-210 D V (50 Hz) 60 Hz: 200 UU V |
| Rated frequency mfr | 60 Hz (60 Hz) |
| Efficiency class mfr | IE3 |
| Rated voltage mfr | 220-240 / 380-420 V (50 Hz) |
| Rated current mfr | 26.8 / 15.5 A (50 Hz) |
| Rated power mfr | 8.6 kW (50 Hz) |
| Efficiency class mfr | IE3 (50 Hz) |
| Rated voltage mfr | 220-240 / 440-480 V (60 Hz) |
| Rated current mfr | 30.6 / 15.3 A (60 Hz) |
| Rated power mfr | 9.9 kW (60 Hz) |
| Efficiency class mfr | IE3 (60 Hz) |
| Rated voltage mfr | 230 / 460 V (60 Hz NEMA) |
| Rated current mfr | 24.0 / 12.0 A (60 Hz NEMA) |
| Rated power mfr | 7.3 kW (60 Hz NEMA) |
| Efficiency class mfr | NP (60 Hz NEMA) |
| Protection rating | IP55 |
| Sound pressure level mfr | 71 dB(A) |
| Sound pressure level mfr | 71 dB(A) (50 Hz) |
| Sound pressure level mfr | 75 dB(A) (60 Hz) |
| Sound pressure level mfr | 75 dB(A) (60 Hz NEMA) |
Description
Construction and series positioning
- The 2BH1640 is a single-stage side-channel blower: a rotating impeller transfers kinetic energy to the gas in a toroidal channel, producing pressure or vacuum without contacting seals or vanes. The drive is an IE3-class 3-phase induction motor integrated on a common shaft, with IP55 protection and class F insulation.
- Within the G-BH1 series, the 2BH1640 is the largest frame among the listed siblings (2BH1009, 2BH1014, 2BH1015, 2BH1023). It is the choice when the required differential pressure or flow exceeds the capacity of the smaller frames; for lower duties, the smaller siblings offer a more compact and lower-power alternative.
- The data sheet covers sizes 1, 2 and 3 with multiple voltage/frequency variants; this model is the 380–420 V / 50 Hz and 200 V / 60 Hz variant (order no. 2BH1640-1GQ47).
Behavior under load and media
- At 50 Hz the maximum differential pressure is -210 mbar in vacuum and +200 mbar in pressure; at 60 Hz these rise to -270 mbar and +300 mbar respectively. The higher frequency also raises motor power from 7.3 kW to 9.9 kW and current from 27.6 A to 35.2 A, so the 60 Hz duty point must be matched to the supply and starter rating.
- The machine is oil-free and contactless in operation; no curve points were supplied, so flow must be taken from the manufacturer's performance curves for the exact voltage/frequency variant. Sound pressure level is 71 dB(A) at the standard measuring condition.
Installation, connection and control
- The motor is a 3-phase machine with dual frequency/voltage data; connection must follow the terminal diagram for the selected supply (380–420 V at 50 Hz or 200 V at 60 Hz). Protection is IP55, so the blower can be installed in dusty or damp industrial environments provided the cable entries are sealed.
- No control electronics, VFD or soft starter are included in the base delivery; the blower is a direct-on-line or starter-driven motor. The data sheet lists UL 1450 and CAN/CSA C22.2 No. 68-09 certification (certificate E225239) for the series.
- The approximate weight of 75 kg requires suitable mounting and lifting provisions; the blower should be fixed on a rigid base with the shaft horizontal unless the manual states otherwise.
Integration & Operating Notes
The maximum differential pressures are -210 mbar (vacuum) and +200 mbar (pressure) at 50 Hz, rising to -270 mbar and +300 mbar at 60 Hz. Operating beyond these limits increases internal leakage and motor load, and can cause overheating or mechanical damage. Size the process restriction so the blower cannot run against a closed or over-restricted line.
Selection & Integration Q&A
Pick the 2BH1640 when your duty needs up to -210 mbar vacuum or +200 mbar pressure at 50 Hz (or -270/+300 mbar at 60 Hz) and the resulting flow exceeds the smaller frames. The 2BH1023 and other siblings are more compact and lower-power; use them only if their pressure/flow curves cover the duty, since the 2BH1640's 7.3–9.9 kW motor and 75 kg mass are significantly larger.
It is a 3-phase IE3 motor wound for 380–420 V/50 Hz or 200 V/60 Hz, drawing 27.6 A or 35.2 A respectively. Provide a starter or DOL contactor with overload protection set to the nameplate current for the actual frequency; no VFD or soft starter is included, and the supply voltage must match the selected variant exactly.
The base delivery is the blower only: no cables, starter, inlet filter or spare parts are included. Because the side-channel principle is oil-free and contactless, service focuses on bearing condition, cooling-air path and any separately supplied inlet filter. Order the mating electrical accessories and filter for your process, and set an inspection interval according to site dust loading.