Elmo Rietschle 2BH1910
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH1910

Elmo Rietschle 2BH1910 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -270 mbar, Motor power 12.6 kW, Noise level 76 dB.

The 2BH1910 is a side-channel (regenerative) blower in Elmo Rietschle's G-BH1 series, driven by a 21.3 kW IE3 motor for 50 Hz operation. It delivers up to 480 mbar differential pressure in pressure mode and -440 mbar in vacuum mode, with a 317 kg cast construction and IP55 protection. This model is the higher-power option in the series, suited for continuous industrial vacuum or pressure duty where moderate flow and high differential are required.

Max. differential pressure
-270 mbar
Motor power
12.6 kW
Noise level
76 dB
Weight
295 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1910 Current 12.676295-22026.4IP55
2BH1009 ——————
2BH1014 0.325711-553.2–6.5IP55
2BH1015 1.36421-1808–16IP55
2BH1023 1.756969-19010–20IP55
2BH1035 2.26470-14014.3–27IP55
2BH1100 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1300 0.2910051-1001.9IP 55
2BH1310 0.75616-2503.8 Δ / 2.20 YIP55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1400 0.956116-1805.6IP55
2BH1410 26528-3006.9IP55
2BH1430 1.164161104.2IP55
2BH1490 0.956116-1404.8 VVIP55
2BH1500 0.956521-904.2IP55
2BH1510 47148-4007.6–15.2IP55
2BH1530 1.66925-904.7IP55
2BH1590 1.36121-1902.75IP55
2BH1600 1.7572311309.9IP55
2BH1610 2.575481606IP55
2BH1630 2.56436-16017.1IP55
2BH1640 4.66565-240–26017.1IP55
2BH1690 2.56434-2009.9IP55
2BH1800 5.87713126011–22IP55
2BH1810 9.974188-46030.8IP55
2BH1830 5.875133-16019.4IP55
2BH1900 8.671183-19030.8IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1940 19.973303-15063.1IP55
2BH1943 17.377330-16072.2 UU / 36.1 UIP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -270 mbar (50 Hz)
60 Hz: -220 mbar
Motor power 12.6 kW (50 Hz)
60 Hz: 14.5 kW
Noise level 72 dB (50 Hz, IE3)
60 Hz, IE3/NP: 76 dB
Max. differential pressure vacuum mfr -440 mbar (50 Hz)
Max. differential pressure vacuum mfr -440 mbar (60 Hz)
Order No. mfr 2BH1910-1HQ36
Order No. mfr 2BH1910-1HQ16 (50 Hz)
Order No. mfr 2BH1910-1HK16 (60 Hz)
Approvals mfr UL and CSA approved
Operating mode mfr continuous operation
Max. differential pressure (pressure) (alt 50 Hz) mfr 240 mbar (50 Hz)
Max. differential pressure (pressure) (alt 60 Hz) mfr 190 mbar (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 295 kg (IE3)
Number of stages 1
Weight approx. mfr 317 kg
Weight approx. mfr 240 kg (50 Hz)
Weight approx. mfr 190 kg (60 Hz)
Weight approx. mfr 190 kg (60 Hz NEMA)
Electrical, Power & Drive Specifications
Current 46.4 A (50 Hz, 190-210 VΔ)
60 Hz, 190-210 VYY / 380-420 VY: 52.8 A · 60 Hz, 190-210 VYY / 380-420 VY (low): 26.4 A · 60 Hz, 200 VYY: 52.8 A
Power supply 3~ 50/60 Hz
Voltage mfr 220-240 / 380-420 V (50 Hz)
Voltage mfr 440-480 V (60 Hz)
Rated current mfr 66.3 Δ / 38.3 Y A (50 Hz)
Rated current mfr 38.0 Y A (60 Hz)
Efficiency class mfr IE3
Mains frequency mfr 50/60 Hz
Voltage tolerance mfr ±10 %
Frequency tolerance mfr ±2 %
Efficiency class mfr IE3 (50 Hz)
Efficiency class mfr IE3 (60 Hz)
Voltage mfr 460 V (60 Hz NEMA)
Efficiency class mfr NP (60 Hz NEMA)
Operating Conditions, Environment & Protection
Protection rating IP55
Sound pressure level mfr 72 dB(A)
Sound pressure level mfr 72 dB(A) (50 Hz)
Sound pressure level mfr 76 dB(A) (60 Hz)
Sound pressure level mfr 76 dB(A) (60 Hz NEMA)

Description

Construction and series positioning

Behavior under load and media

Installation, connection and control

Integration & Operating Notes

Electrical
Verify supply voltage and frequency tolerance before connection

The motor is designed for ±10% voltage tolerance and ±2% frequency tolerance. Exceeding these limits can cause overheating, reduced insulation life, or immediate failure. Confirm the site supply matches the nameplate configuration (Δ or Y) and that the correct overload protection is set to the rated current for the chosen connection.

Factory Specification Sheet
Mounting
Install on a rigid, level foundation with adequate ventilation

The 317 kg weight and dynamic forces require a solid mounting surface. Ensure the blower is level and bolted down to prevent vibration. Maintain at least the minimum clearance around the cooling air inlet and outlet as specified in the manual to avoid recirculation of hot air. The IP55 rating permits outdoor installation.

Instruction Manual, Section 3 Installation
Control & I/O
Use star-delta or soft starter to limit inrush current

Direct-on-line starting of the 12.6 kW motor will draw high inrush current (typically 6-8 times rated). This can cause voltage dips and trip upstream protection. A star-delta starter or soft starter is recommended to reduce starting current and mechanical shock. Ensure the starter is rated for the motor power and set the overload relay to the rated current for the selected connection.

Instruction Manual, Section 4 Electrical Connection
Maintenance
Regularly inspect and clean the impeller and inlet filter

Because the blower handles air, dust and particles can accumulate on the impeller and in the inlet, causing imbalance and reduced performance. Inspect and clean the impeller and inlet screen at intervals determined by the contamination level of the process air. Replace the inlet filter (if fitted) when pressure drop increases. Bearings are sealed and require no lubrication.

Instruction Manual, Section 6 Maintenance

Selection & Integration Q&A

When should I choose the 2BH1910 over the smaller 2BH1023 or larger siblings?

Choose the 2BH1910 when your required differential pressure is near 480 mbar (pressure) or -440 mbar (vacuum) and flow demands are moderate. The 2BH1023 offers lower power and pressure. Select based on the intersection of your system curve with the blower curve.

What are the requirements for the electrical supply and protection for this blower?

The 2BH1910 requires a 3-phase supply matching the nameplate voltage (e.g., 380–420 V Y at 50 Hz) with ±10% voltage and ±2% frequency tolerance. Use a motor protection circuit breaker or overload relay set to 38.3 A (Y at 50 Hz) or 66.3 A (Δ at 50 Hz). A soft starter or star-delta starter is recommended to limit inrush current.

What maintenance is required and what consumables are not included in the base delivery?

Regular maintenance includes cleaning the impeller and inlet filter (if fitted) and checking for vibration. Bearings are sealed for life. No consumables are included in the base delivery; inlet filters, silencers, and flexible connectors must be ordered separately. Refer to the manual for specific intervals based on operating conditions.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH1910 IE3 vacuum pump (EN)
Datasheet ·322,8 КБ ·2 pp.
View PDF