Elmo Rietschle 2BH1943
Elmo Rietschle 2BH1943 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -160 mbar, Motor power 19.9 kW, Noise level 77 dB.
The 2BH1943 is a side-channel blower from the G-BH1 series, driven by a 17.3 kW IE3 motor for 50 Hz operation (19.9 kW at 60 Hz). It delivers up to 170 mbar differential pressure and -160 mbar vacuum at 50 Hz, with lower limits at 60 Hz. This model is intended for high-demand vacuum or pressure applications in industrial systems.
Elmo Rietschle G-BH1 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Weight, kg | Max. differential pressure, mbar | Current, A | Protection rating |
|---|---|---|---|---|---|---|
| 2BH1943 Current | 17.3 | 77 | 330 | -160 | 72.2 UU / 36.1 U | IP55 |
| 2BH1009 | — | — | — | — | — | — |
| 2BH1014 | 0.32 | 57 | 11 | -55 | 3.2–6.5 | IP55 |
| 2BH1015 | 1.3 | 64 | 21 | -180 | 8–16 | IP55 |
| 2BH1023 | 1.75 | 69 | 69 | -190 | 10–20 | IP55 |
| 2BH1035 | 2.2 | 64 | 70 | -140 | 14.3–27 | IP55 |
| 2BH1100 | 0.2 | 53 | 10 | -120 | 1.39 Δ / 0.80 Y | IP 55 |
| 2BH1200 | 0.29 | 40 | 57 | -40 | 1.38 0.8 Y | IP55 |
| 2BH1300 | 0.29 | 100 | 51 | -100 | 1.9 | IP 55 |
| 2BH1310 | 0.7 | 56 | 16 | -250 | 3.8 Δ / 2.20 Y | IP55 |
| 2BH1330 | 0.29 | 80 | 51 | — | 1.74 Δ / 1.0 Y | IP55 |
| 2BH1400 | 0.95 | 61 | 16 | -180 | 5.6 | IP55 |
| 2BH1410 | 2 | 65 | 28 | -300 | 6.9 | IP55 |
| 2BH1430 | 1.1 | 64 | 16 | 110 | 4.2 | IP55 |
| 2BH1490 | 0.95 | 61 | 16 | -140 | 4.8 VV | IP55 |
| 2BH1500 | 0.95 | 65 | 21 | -90 | 4.2 | IP55 |
| 2BH1510 | 4 | 71 | 48 | -400 | 7.6–15.2 | IP55 |
| 2BH1530 | 1.6 | 69 | 25 | -90 | 4.7 | IP55 |
| 2BH1590 | 1.3 | 61 | 21 | -190 | 2.75 | IP55 |
| 2BH1600 | 1.75 | 72 | 31 | 130 | 9.9 | IP55 |
| 2BH1610 | 2.5 | 75 | 48 | 160 | 6 | IP55 |
| 2BH1630 | 2.5 | 64 | 36 | -160 | 17.1 | IP55 |
| 2BH1640 | 4.6 | 65 | 65 | -240–260 | 17.1 | IP55 |
| 2BH1690 | 2.5 | 64 | 34 | -200 | 9.9 | IP55 |
| 2BH1800 | 5.8 | 77 | 131 | 260 | 11–22 | IP55 |
| 2BH1810 | 9.9 | 74 | 188 | -460 | 30.8 | IP55 |
| 2BH1830 | 5.8 | 75 | 133 | -160 | 19.4 | IP55 |
| 2BH1900 | 8.6 | 71 | 183 | -190 | 30.8 | IP55 |
| 2BH1910 | 12.6 | 76 | 295 | -220 | 26.4 | IP55 |
| 2BH1930 | 8.6 | 75 | 212 | -80 | 17.6–35.2 | IP55 |
| 2BH1940 | 19.9 | 73 | 303 | -150 | 63.1 | IP55 |
Full specifications
| Max. differential pressure | -160 mbar (50 Hz, variant 1GK21) 60 Hz, variant 1GK21: -120 mbar |
| Motor power | 17.3 kW (50 Hz, variant 1GK21) 60 Hz, variant 1GK21: 19.9 kW |
| Noise level | 73 dB(A) (50 Hz, variant 1GK21) 60 Hz, variant 1GK21: 77 dB(A) |
| Series mfr | G-BH 1 N |
| Type mfr | 2BH1943-1GQ37 (50 Hz) |
| Type mfr | 2BH1943-1GQ37 (60 Hz) |
| Max. differential pressure Vacuum mfr | -120 mbar (60 Hz) |
| Approvals mfr | UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate |
| Max. differential pressure (alt 50 Hz, variant 1GK21) mfr | 170 mbar (50 Hz, variant 1GK21) |
| Max. differential pressure (alt 60 Hz, variant 1GK21) mfr | 110 mbar (60 Hz, variant 1GK21) |
| Weight | 330 kg (variant 1GK21) |
| Number of stages | 1 (variant 1GK21) |
| Weight approx. mfr | 342 kg (60 Hz) |
| Current | 63.1 D A (50 Hz, variant 1GK21) 60 Hz, variant 1GK21: 72.2 UU / 36.1 U A |
| Power supply | 3~ 50/60 Hz |
| Voltage | 190-210 D V (50 Hz, variant 1GK21) 60 Hz, variant 1GK21: 190-210 UU / 380-420 U V |
| Efficiency class mfr | IE3 (50 Hz) |
| Efficiency class mfr | IE3 (60 Hz) |
| Protection rating | IP55 |
| Operating temperature | up to 25 degC |
| Sound pressure level mfr | 73 dB(A) (50 Hz) |
| Sound pressure level mfr | 77 dB(A) (60 Hz) |
Description
Construction and positioning
- The 2BH1943 is a side-channel (regenerative) blower with a three-phase IE3 motor, IP55 protection, and insulation class F. It is a high-capacity model in the G-BH1 series, outweighing smaller siblings such as the 2BH1009, 2BH1014, 2BH1015, and 2BH1023.
- The motor is designed for dual voltage: 380-420 V delta / 660-725 V star at 50 Hz, and 440-480 V delta at 60 Hz. The 50 Hz variant draws 31.7 A in delta and 18.3 A in star; the 60 Hz variant draws 31.4 A in delta.
- The blower is approved to UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate E225239), making it suitable for North American markets.
Performance behavior
- At 50 Hz, maximum differential pressure is 170 mbar in pressure mode and -160 mbar in vacuum mode. At 60 Hz, the corresponding limits are 110 mbar and -120 mbar, respectively. These values are taken from the manufacturer's data sheet for the specified voltage variants; the reason for the lower 60 Hz limits is not stated in the supplied data and should be confirmed with the manufacturer if operation at 60 Hz is intended.
- Sound pressure level is 73 dB(A) at 50 Hz and 77 dB(A) at 60 Hz. Measurement conditions (distance, free-field or ducted) are not specified in the supplied data; obtain the measurement standard from the manufacturer if acoustic compliance is required.
- The blower is not intended for continuous operation at the maximum differential pressure without considering thermal limits; the motor's IE3 efficiency reduces losses but does not eliminate heat generation.
Installation and operation
- The blower must be mounted securely on a level surface, with sufficient clearance for cooling air intake and exhaust. The IP55 rating allows operation in dusty and wet environments, but the motor cooling fins must remain unobstructed.
- Electrical connection requires a suitable motor protection switch and cables rated for the full load current. The dual-voltage design allows star-delta starting at 50 Hz, but direct-on-line starting is permissible only if the supply can handle the high inrush current.
- The blower can be used in either pressure or vacuum mode by connecting the inlet or outlet to the process. No specific control or monitoring devices are included in the base delivery; the user must provide overload protection and, if necessary, a non-return valve to prevent backflow when stopped.
Integration & Operating Notes
The full-load current at 50 Hz in delta connection is 31.7 A. Select cables, contactors, and overload relays for at least this current, and consider the higher starting current. At 60 Hz, the current is 31.4 A in delta. Incorrect protection can lead to motor overheating or nuisance tripping.
The motor relies on fan cooling. Install the blower with sufficient clearance around the cooling air inlet and outlet, and avoid recirculating hot air. In enclosed spaces, ensure adequate ventilation or ducting to maintain ambient temperature within the motor's rating.
Operating beyond these differential pressure limits can cause excessive heating, increased noise, and mechanical stress, potentially damaging the blower. At 60 Hz, the limits are 110 mbar pressure and -120 mbar vacuum. Always verify the actual operating point against the performance curve.
Direct-on-line starting of a 17.3 kW motor may cause significant voltage dips. If the supply is weak, use star-delta starting (possible with dual-voltage motor) or a soft starter. Ensure the starting method is compatible with the load characteristics of the blower.
Dust accumulation on cooling fins reduces heat dissipation and can lead to motor overheating. If an inlet filter is used, clean or replace it according to the manufacturer's schedule. No specific maintenance intervals are provided in the data sheet; follow general good practice.
Selection & Integration Q&A
Choose the 2BH1943 when your process requires differential pressures up to 170 mbar or vacuum to -160 mbar at 50 Hz, and flow rates that the smaller models cannot achieve. The 2BH1023 and others in the series have lower capacity. If your demand is below 100 mbar, a smaller model may be more efficient and cost-effective.
The motor requires a 3-phase supply of 380-420 V (delta) or 660-725 V (star) at 50 Hz, or 440-480 V (delta) at 60 Hz. Use motor protection rated for 31.7 A (50 Hz) or 31.4 A (60 Hz). Ensure the supply can handle starting current; consider star-delta starting. Cables and components must be rated for the full load current and voltage.
The blower has IP55 protection, so it can operate in dusty and wet environments. However, ambient temperature must not exceed the motor's rating (typically 40°C). Continuous operation at maximum differential pressure may cause overheating; ensure adequate cooling. No specific duty cycle is given, but the motor is designed for continuous operation (S1) under rated conditions.
The base delivery includes the blower only. You must provide electrical cables, motor protection, and any piping or fittings. Optional accessories such as inlet filters, silencers, or non-return valves are not included and should be ordered separately. Regular maintenance includes cleaning cooling fins and checking for wear; no specific spare parts list is provided in the data sheet.