Peter Huber Kältemaschinenbau Unistat 1005w Dynamisches
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unistat 1005w Dynamisches

Peter Huber Kältemaschinenbau Unistat 1005w Dynamisches — Temperature control units.

The Unistat 1005w Dynamisches is a water-cooled refrigerated heating circulator with a stainless-steel variable-speed pressure pump, covering -120 to 100 °C via a three-stage cascade (R-452A/R-23/R-14). Within the Unistat w-series it is the 10x5 frame size, positioned above the 705w/815w/825w and below the 1015w. It serves externally closed or open temperature control loops requiring 2 kW heating and up to 30 l/min circulation.

Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection

Model Noise level, dBAmbient temperature limit, °CDisplay resolutionPower supplyPump connectionPump type
Unistat 1005w Dynamisches Current —5–400, 01400V 3~ 50HzM30x1, 5 AG malePressure pump, variable
Unistat 1015w Dynamisches —5–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat 705w Dynamisches —5–400, 01230V 1~ 50HzM24x1, 5 AG malePressure pump, variable
Unistat 815w Dynamisches 605–400, 01400V 3~ 50HzM30x1, 5 AG malePressure pump, variable
Unistat 825w Dynamisches —5–400, 01400V 3~ 50HzM30x1, 5 AG malePressure pump, variable
Unistat 905w Dynamisches —5–400, 01 K208V 3~ 60HzM30x1, 5 AG malemagnetically coupled, st
Unistat 912w Dynamisches 655–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat 915w Dynamisches 645–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat 920w Dynamisches 715–400, 01400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st
Unistat 930w Dynamisches —5–400, 01460V 3~ 60HzM38x1, 5 AG malemagnetically coupled, st
Unistat 950w Dynamisches —5–400, 01400V 3~ 50Hzflange DN40 PN10/40 EN10magnetically coupled, st
Unistat P815 Dynamisches 645–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat P815w Dynamisches —5–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat P825 Dynamisches —5–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat P825w Dynamisches —5–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat P905 Dynamisches —5–350, 01460V 3~ 60HzM30x1, 5 AG malemagnetically coupled, st
Unistat P905w Dynamisches —5–400, 01460V 3~ 60HzM30x1, 5 AG malemagnetically coupled, st
Unistat P912w Dynamisches 655–400, 01460V 3~ 60HzM30x1, 5 AG malemagnetically coupled, st
Unistat P915w Dynamisches 645–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat P920w Dynamisches —5–400, 01400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st
Unistat P925w Dynamisches —5–400, 01400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st
Unistat P930w Dynamisches —5–400, 01400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st
Unistat P950w Dynamisches —5–400, 01400V 3~ 50Hzflange DN40 PN10/40 EN10magnetically coupled, st

Full specifications

Core Performance & Functional Specifications
Control output POKO ONE
Expansion volume 8 l
Heating capacity 2 kW
Pump connection M30x1, 5 AG male
Pump speed adjustable Yes
Pump type Pressure pump, variable speed
External sensor connection Pt100
Temperature range -120...100 °C
Dimensions, Weight & Mechanical Design
Weight 340 kg
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Maximum viscosity 50 mm²/s
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G1/2 male
Cooling water consumption 300 l/h (at 15°C, flow 0°C)
Cooling water differential pressure 3 bar
Cooling Water Pressure 6 bar
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Working range and load behavior

Installation, connection and operation

Integration & Operating Notes

Process Limits
Expansion vessel must stay unlocked for externally closed loops

For externally closed applications the expansion vessel must remain unlocked; locking it causes overpressure damage to the application. Conversely, externally open (bath) applications require the vessel locked to prevent fluid loss. The setting must be verified before commissioning, not after the first temperature cycle.

Unistat Operation Manual, page 33
Process Limits
Process Safety needs the compressor set to Permanently ON

In Process Safety mode the controller releases maximum cooling capacity at the OT trigger instead of isolating all poles, which protects exothermic processes and glass breakage scenarios. This mode only functions if the compressor is configured to Permanently ON; otherwise the protective cooling is not available when the trigger is reached.

Unistat Operation Manual, page 19
Control & I/O
Decide power-failure restart policy before unattended operation

The Pilot ONE can be set to Off/Standby (default, manual restart) or ON/Temperature control active, and Power Failure Auto resumes temperature control after an outage if it was active. Choose according to whether an unattended restart is safe for the process; the INFO window at startup allows automatic start to be cancelled for a few seconds.

Unistat Operation Manual — Unistat 5, Unistat Pilot ONE, Section 1.8.1, page 21

Selection & Integration Q&A

When should I choose the 1005w over the 815w/825w or step up to the 1015w?

Pick the 1005w when the duty needs the 10x5 frame's 2 kW heating and 30 l/min pump at -120...100 °C with water cooling. The 815w/825w are smaller frames; the 1015w is the next size up. Note the 705w lacks a plate heat exchanger, so the dynamic-change warning applies here but not there.

What must the external circuit and cooling water supply provide for this unit to work?

The process loop must fit the pump curve: 30 l/min max at 0.9 bar, falling to 8 l/min at 0.8 bar, so check external pressure drop. Cooling water needs G1/2 male connections, 3–6 bar differential and 5–20 °C intake; 300 l/h is the reference at 15 °C water with 0 °C flow.

What installation and duty-cycle limits does the manual impose on this model?

Install upright on leveling feet with brakes engaged, ambient 5–40 °C, IP20 dry location, no ATEX zone. Allow 2 h acclimation after cold/warm moves. Transport only empty and upright. Shut off cooling water even overnight. FL fluid needs fire point ≥65 °C; ethanol only supervised.

What maintenance and accessories are needed beyond the base delivery?

Base delivery includes cable but no plug for this <63 A three-phase unit. Plan periodic hose/connection inspection and replacement, hat-type strainer cleaning with circuit drain, liquefier fin cleaning and heat transfer fluid inspection/replacement. A drip tray below the unit is required by the responsible body; refrigerant work needs approved contractors.