Peter Huber Kältemaschinenbau Unistat 950w Dynamisches
Peter Huber Kältemaschinenbau Unistat 950w Dynamisches — Temperature control units.
The Unistat 950w Dynamisches is a water-cooled, free-standing temperature control unit with a magnetically coupled stainless-steel pump and a -90…200 °C working range. It is the largest modification in the Unistat w Dynamisches series, distinguished by 36 kW heating and a 240 l/min pump. It serves as a high-capacity circulation source for externally closed industrial processes requiring precise temperature control.
Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection
| Model | Noise level, dB | Ambient temperature limit, °C | Display resolution | Power supply | Pump connection | Pump type |
|---|---|---|---|---|---|---|
| Unistat 950w Dynamisches Current | — | 5–40 | 0, 01 | 400V 3~ 50Hz | flange DN40 PN10/40 EN10 | magnetically coupled, st |
| Unistat 1005w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | Pressure pump, variable |
| Unistat 1015w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 705w Dynamisches | — | 5–40 | 0, 01 | 230V 1~ 50Hz | M24x1, 5 AG male | Pressure pump, variable |
| Unistat 815w Dynamisches | 60 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | Pressure pump, variable |
| Unistat 825w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | Pressure pump, variable |
| Unistat 905w Dynamisches | — | 5–40 | 0, 01 K | 208V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 912w Dynamisches | 65 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 915w Dynamisches | 64 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 920w Dynamisches | 71 | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat 930w Dynamisches | — | 5–40 | 0, 01 | 460V 3~ 60Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat P815 Dynamisches | 64 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P815w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P825 Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P825w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P905 Dynamisches | — | 5–35 | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P905w Dynamisches | — | 5–40 | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P912w Dynamisches | 65 | 5–40 | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P915w Dynamisches | 64 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P920w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat P925w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat P930w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat P950w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | flange DN40 PN10/40 EN10 | magnetically coupled, st |
Full specifications
| Control output | POKO ONE |
| Expansion volume | 90 l |
| Filling volume | 30 l |
| Heating capacity | 36 kW |
| Pump connection | flange DN40 PN10/40 EN1092-1 |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | -90...200 °C |
| Weight | 2147 kg |
| Current consumption | 120 A |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 100 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G1 1/4 male |
| Cooling water consumption | 5000 l/h (at 15°C, flow 0°C) |
| Cooling water differential pressure | 3 bar |
| Cooling Water Pressure | 6 bar |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Free-standing, water-cooled (w) unit with a magnetically coupled stainless-steel circulation pump; no mechanical seal in the fluid path.
- Pump connection is a flange DN40 PN10/40 EN1092-1; cooling water connection is G1 1/4 male.
- Within the Unistat w Dynamisches series, the 950w is the largest sibling listed (alongside 705w, 815w, 1005w, 1015w); its 36 kW heating capacity and 240 l/min maximum pump delivery set it apart from the smaller 705w/815w.
- Overall dimensions 2630×1300×1980 mm and net weight 2147 kg require structural floor assessment and a defined transport route.
Behavior under load and media
- Temperature range -90…200 °C; display resolution 0.01 K.
- Pump curve: 240 l/min at 4 bar max, 207 l/min at 1.0 bar, 167 l/min at 2.0 bar, 115 l/min at 3.0 bar — external circuit pressure drop must be checked against this curve.
- Maximum permissible kinematic viscosity of the heat transfer fluid is 100 mm²/s; fluid selection must respect this, especially at low temperatures.
- Cooling water intake must be 5…20 °C; cooling power drops as cooling water temperature rises. Below the condensation point, cooling water pipes inside the unit must be insulated.
- Safety classification III / FL with adjustable overtemperature protection per DIN 12876; in Process Safety mode the controller releases maximum cooling instead of switching off all poles.
Installation, connection and control
- Power supply 400 V 3~ 50 Hz, max current 120 A, fusing 3×125 A; voltage tolerance ±5% only with simultaneous frequency tolerance ±2%, and combinations such as -5% voltage with +2% frequency are not allowed.
- Three-phase devices drawing more than 63 A are supplied without cable and without plug; the customer must provide the power connection.
- Cooling water: 5000 l/h at 15 °C, min differential pressure 3 bar, max pressure 6 bar.
- Controller Pilot ONE with POKO ONE control output; interfaces Ethernet, USB (Host and Device), RS232; external sensor connection Pt100.
- Ambient temperature 5…40 °C; protection rating IP20.
- Refrigerant charge: R-507 19.5 kg (GWP 3985, 77.7 t CO2e) and R-23 7 kg (GWP 14800, 103.6 t CO2e).
Integration & Operating Notes
Voltage may deviate ±5% only if frequency simultaneously deviates ±2%; combinations such as -5% voltage with +2% frequency are not allowed. Verify the site supply quality before connection, because out-of-tolerance combinations can damage the unit or void compliance.
Because the unit draws 120 A, it is delivered without cable and without plug. The customer must provide the three-phase power connection, sized for 120 A with 3×125 A fusing, and have the hard-wired connection performed by an electrician.
The unit is designed for cooling water intake between 5 °C and 20 °C, and cooling power drops as the cooling water temperature rises. If the cooling water temperature falls below the condensation point, the cooling water pipes inside the unit must be insulated to prevent condensation and corrosion.
The cooling water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM. Only cooling water compatible with these materials may be used; aggressive or untreated water can corrode the circuit.
Without an Ex px cabinet the unit is not protected against explosion. Site selection must exclude ATEX zones; operation in an Ex px cabinet requires the separate ATEX annex and only the model/serial number stated on the Ex px cabinet rating plate is suitable.
Only transport the unit upright and emptied; horizontal transport damages the compressor and a filled unit risks thermal fluid overflow. Casters, if present, are not suitable for transport and carry only 25% of total mass symmetrically — use an industrial truck. Leveling feet must be activated and parking brakes engaged before commissioning.
For externally closed applications the expansion vessel must remain unlocked; locking it causes overpressure damage. For externally open (bath) applications the expansion vessel must be locked to prevent fluid loss. Verify the lock state before filling and commissioning.
The maximum permissible kinematic viscosity of the heat transfer fluid is 100 mm²/s. At low temperatures viscosity rises, so fluid selection must ensure this limit is respected across the entire operating range down to -90 °C.
In Process Safety mode, when the overtemperature trigger value is reached the controller releases maximum cooling capacity instead of switching off all poles. This mode requires the compressor to be set to Permanently ON; configure this before relying on Process Safety for exothermic process protection.
After a power outage or when switching on, the response can be set via Pilot ONE: 'Off/Standby' (default, temperature control started only by manual input) or 'ON/Temperature control active' (temperature control always started after turning on, with an INFO shown for a few seconds allowing automatic startup to be disabled). Choose according to whether unattended restart is acceptable for the process.
Shut off the cooling water supply to the temperature control unit even for shorter downtimes such as overnight, to prevent water damage and unnecessary load on the cooling water circuit.
Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors. General maintenance personnel cannot perform refrigerant-circuit maintenance. The unit contains R-507 (19.5 kg) and R-23 (7 kg), with CO2 equivalents of 77.7 t and 103.6 t respectively.
Selection & Integration Q&A
Choose the 950w when the process needs 36 kW heating and up to 240 l/min pump delivery at 4 bar; the 705w and 815w are smaller siblings. The 950w is the largest listed w Dynamisches model, so select it for high heat-load or high-flow external circuits where the smaller units cannot meet the duty point.
Provide 400 V 3~ 50 Hz with 120 A max current and 3×125 A fusing. Because the unit draws more than 63 A, it is supplied without cable and without plug; the customer must provide the three-phase connection, performed by an electrician. Voltage tolerance is ±5% only with simultaneous ±2% frequency tolerance.
Install outside ATEX zones, with ambient temperature 5…40 °C and IP20 protection. Transport upright and empty; casters are not for transport. Allow about 2 hours acclimation when moving between cold and warm environments before power-on. Cooling water intake must be 5…20 °C at 5000 l/h, min 3 bar differential, max 6 bar.
The power cable and plug are not included for this >63 A unit. A condensation water/heat transfer fluid drip tray must be installed by the responsible body. Hoses and connections must be periodically checked and replaced as needed. Cooling water must be shut off even overnight. Refrigerant-circuit work requires approved contractors.