| Parameter | Value | Condition |
|---|---|---|
| Rated voltage | 230 Δ / 400 Y V p.2 ↗ | 2BH1 100, 50 Hz |
| Rated current | 1,20 Δ / 0,69 Y A p.2 ↗ | 2BH1 100, 50 Hz |
| Power | 0,25 kW p.2 ↗ | 2BH1 100, 50 Hz |
| Max. differential pressure vacuum | -90 mbar p.2 ↗ | 2BH1 100, 50 Hz |
| Max. differential pressure pressure | 100 mbar p.2 ↗ | 2BH1 100, 50 Hz |
| Rated voltage | 460 Y V p.2 ↗ | 2BH1 100, 60 Hz |
| Rated current | 0,66 Y A p.2 ↗ | 2BH1 100, 60 Hz |
| Power | 0,29 kW p.2 ↗ | 2BH1 100, 60 Hz |
| Max. differential pressure vacuum | -120 mbar p.2 ↗ | 2BH1 100, 60 Hz |
| Max. differential pressure pressure | 110 mbar p.2 ↗ | 2BH1 100, 60 Hz |
| Sound pressure level | 100 dB(A) p.2 ↗ | 2BH1 100, 50 Hz |
| Sound pressure level | 110 dB(A) p.2 ↗ | 2BH1 100, 60 Hz |
| Weight approx. | 100 kg p.2 ↗ | 2BH1 100, 50 Hz |
| Weight approx. | 110 kg p.2 ↗ | 2BH1 100, 60 Hz |
| Insulation material class | cl. p.2 ↗ | 3~ 50/60 Hz |
Operating Limits
- Max. ambient / suction temperature for performance data: 25 °C p.1 ↗
- Performance tolerance: ± 10 % p.1 ↗
- ATEX category 3GD: II 3G IIB T3 Gc and II 3D IIIB T125°C Dc p.2 ↗
- ATEX category 3/2D: II 3/2D IIIC T125°C Dc/Db p.2 ↗
- ATEX category 3/2G: II 3/2G IIB T3 Gc/Gb p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BH1 | Series / type designation (side channel blower G-BH1) |
| 5-7 p.2 ↗ | 100 | Size designation |
| field 1 p.2 ↗ | D | ATEX category 3/2D (includes 3D(i) and 2D(o)) |
| field 1 p.2 ↗ | G | ATEX category 3/2G (includes 3G(i) and 2G(o)) |
| field 2 p.2 ↗ | 1 | Voltage variant 230 Δ / 400 Y (50 Hz) or 460 Y (60 Hz) |
| field 2 p.2 ↗ | 6 | Voltage variant 400 Δ / 690 Y (50 Hz) or 460 Δ (60 Hz) |
| field 2 p.2 ↗ | 5 | Voltage variant 500 Δ (50 Hz) or 575 Δ (60 Hz) |
Related models
Elmo Rietschle 2BH1009
Elmo Rietschle 2BH1014
Elmo Rietschle 2BH1015
Elmo Rietschle 2BH1023
Elmo Rietschle 2BH1035
Elmo Rietschle 2BH1100
Elmo Rietschle 2BH1200
Elmo Rietschle 2BH1300
Elmo Rietschle 2BH1310
Elmo Rietschle 2BH1330
Elmo Rietschle 2BH1400
Elmo Rietschle 2BH1410
Elmo Rietschle 2BH1430
Elmo Rietschle 2BH1490
Elmo Rietschle 2BH1500
Elmo Rietschle 2BH1510
Elmo Rietschle 2BH1530
Elmo Rietschle 2BH1590
Elmo Rietschle 2BH1600
Elmo Rietschle 2BH1610
Elmo Rietschle 2BH1630
Elmo Rietschle 2BH1640
Elmo Rietschle 2BH1690
Elmo Rietschle 2BH1800
Elmo Rietschle 2BH1810
Elmo Rietschle 2BH1830
Elmo Rietschle 2BH1900
Elmo Rietschle 2BH1910
Elmo Rietschle 2BH1930
Elmo Rietschle 2BH1940
Elmo Rietschle 2BH1943