Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — G-BH1 2BH1330 ATEX vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH1 330: side channel blower in ATEX configuration (G-BH1 N). Covers ATEX categories 3GD and 3/2D as fixed-voltage machines for 50 and 60 Hz; category 3/2G available only as 50 Hz or 60 Hz versions. Ordering code 2BH1…-1.□.□-Z with Z substitutions D1, D6, D5, G1, G6, G5 and M34/M74.

Technical Data

Parameter Value Condition
Rated voltage 230 / 400 V p.2 ↗ 2BH1 330, 50 Hz, delta / Y
Rated current 2,35 / 1,34 A p.2 ↗ 2BH1 330, 50 Hz, delta / Y
Motor power 0,55 kW p.2 ↗ 2BH1 330, 50 Hz
Max. differential pressure -120 mbar p.2 ↗ 2BH1 330, 50 Hz
Sound pressure level 54 dB(A) p.2 ↗ 2BH1 330, 50 Hz
Weight 130 kg p.2 ↗ 2BH1 330, 50 Hz
Rated voltage 460 V p.2 ↗ 2BH1 330, 60 Hz, Y
Rated current 1,34 A p.2 ↗ 2BH1 330, 60 Hz, Y
Motor power 0,63 kW p.2 ↗ 2BH1 330, 60 Hz
Max. differential pressure -150 mbar p.2 ↗ 2BH1 330, 60 Hz
Sound pressure level 57 dB(A) p.2 ↗ 2BH1 330, 60 Hz
Weight 160 kg p.2 ↗ 2BH1 330, 60 Hz

Operating Limits

  • Max. suction and ambient temperature for stated total pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ±10 % p.1 ↗
  • Reference air temperature for performance curves: 15 °C p.1 ↗
  • Reference atmospheric pressure for performance curves: 1013 mbar p.1 ↗
  • Sound pressure level tolerance: ±3 dB(A) p.2 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH1 Type series (side channel blower, G-BH1 N)
field 1 p.2 ↗ 1 Version / design field
field 2 p.2 ↗ □ Voltage connection variant: D1 = 230 Δ / 400 Y (50 Hz), 460 Y (60 Hz); D6 = 400 Δ / 690 Y (50 Hz), 460 Δ (60 Hz); D5 = 500 Δ (50 Hz), 575 Δ (60 Hz); G1 = 460 Y (60 Hz only); G6 = 460 Δ (60 Hz only); G5 = 575 Δ (60 Hz only)
field 3 p.2 ↗ □ ATEX category / motor variant: M34, M74 for 3/2D, 3GD