Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — G-BH1 2BH1500 IE3 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH1 500: side channel blower with integrated frequency converter (VFD). Covers 2BH1500-1A336 (380 V, 87 Hz, 4.3 kW), 2BH1500-1AK26 (400 V, 50 Hz, 2.9 kW), 2BH1500-1AK36 (400 V, 87 Hz, 4.3 kW), plus integrated VFD types 2FC4xxx-1□□00 and accessories.

Technical Data

Parameter Value Condition
Rated motor voltage 380 V p.2 ↗ 2BH1500-1A336, 87 Hz
Rated motor current 8,8 A p.2 ↗ 2BH1500-1A336, 87 Hz
Motor power 4,3 kW p.2 ↗ 2BH1500-1A336, 87 Hz
Max. differential pressure, vacuum -300 mbar p.2 ↗ 2BH1500-1A336, 87 Hz
Max. differential pressure, pressure 270 mbar p.2 ↗ 2BH1500-1A336, 87 Hz
Sound pressure level 78 dB(A) p.2 ↗ 2BH1500-1A336, 87 Hz
Weight 40,8 kg p.2 ↗ 2BH1500-1A336, 87 Hz
Rated motor voltage 400 V p.2 ↗ 2BH1500-1AK26, 50 Hz
Motor power 2,9 kW p.2 ↗ 2BH1500-1AK26, 50 Hz
Max. differential pressure, vacuum -250 mbar p.2 ↗ 2BH1500-1AK26, 50 Hz
Max. differential pressure, pressure 310 mbar p.2 ↗ 2BH1500-1AK26, 50 Hz
Sound pressure level 69 dB(A) p.2 ↗ 2BH1500-1AK26, 50 Hz
Weight 34 kg p.2 ↗ 2BH1500-1AK26, 50 Hz
Rated motor voltage 400 V p.2 ↗ 2BH1500-1AK36, 87 Hz
Rated motor current 8,7 A p.2 ↗ 2BH1500-1AK36, 87 Hz
Motor power 4,3 kW p.2 ↗ 2BH1500-1AK36, 87 Hz
Max. differential pressure, vacuum -300 mbar p.2 ↗ 2BH1500-1AK36, 87 Hz
Max. differential pressure, pressure 270 mbar p.2 ↗ 2BH1500-1AK36, 87 Hz
Sound pressure level 78 dB(A) p.2 ↗ 2BH1500-1AK36, 87 Hz
Weight 36 kg p.2 ↗ 2BH1500-1AK36, 87 Hz
Protection class IP55 p.2 ↗ motor
Insulation material class F p.2 ↗ motor
VFD rated mains voltage 3~ 400V -15% … 480V +10% V p.2 ↗ integrated VFD
VFD mains frequency 50/60 Hz p.2 ↗ integrated VFD, ±6%

Operating Limits

  • Max. ambient/suction temperature for stated pressure differences: 25 °C p.1 ↗
  • Min. mains voltage for frequency converter: 380 V p.1 ↗
  • Min. pulse frequency for performance curves: 4 kHz p.1 ↗
  • Protection class: IP55 p.2 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH150 Type/size designation (2BH1 500)
11-12 p.2 ↗ K2 Voltage/frequency variant (K2 = 400 V, 50 Hz)
11-12 p.2 ↗ K3 Voltage/frequency variant (K3 = 400 V, 87 Hz)
VFD field 1 p.2 ↗ A-K VFD size letter (A=1.5 kW … K=22 kW)
VFD field 2 p.2 ↗ □ Placeholder for voltage/frequency variant in VFD order number 2FC4xxx-1□□00

Ordering Data

Ordering Code Part No. Variant / Code Applies To Note
2BH1500-1A336 p.2 ↗ 2BH1500-1A336 380 V, 87 Hz Integrated VFD, 4.3 kW
2BH1500-1AK26 p.2 ↗ 2BH1500-1AK26 400 V, 50 Hz 2.9 kW
2BH1500-1AK36 p.2 ↗ 2BH1500-1AK36 400 V, 87 Hz 4.3 kW