Technical Data Sheet — G-BH1 2BH1630 ATEX vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Data sheet 2BH1 630: side channel blower in ATEX configuration (G-BH1 N), 2BH1630 size; ATEX categories 3GD, 3/2D and 3/2G; fixed-voltage machines for 50 and 60 Hz (3/2G only 50 Hz or 60 Hz versions); ordering code 2BH1…-1.□.□-Z with Z=M34/M74/M71 and D/G voltage variants.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated voltage | 400 / 690 V p.2 ↗ | 2BH1630, 50 Hz, Δ/Y |
| Rated current | 4.20 / 2.40 A p.2 ↗ | 2BH1630, 50 Hz, Δ/Y |
| Rated power | 3.0 hp p.2 ↗ | 2BH1630, 50 Hz |
| Max. vacuum | -52 inch H2O p.2 ↗ | 2BH1630, 50 Hz |
| Max. pressure | 48 inch H2O p.2 ↗ | 2BH1630, 50 Hz |
| Sound pressure level | 64 dB(A) p.2 ↗ | 2BH1630, 50 Hz |
| Rated voltage | 460 V p.2 ↗ | 2BH1630, 60 Hz, Δ |
| Rated current | 4.20 A p.2 ↗ | 2BH1630, 60 Hz, Δ |
| Rated power | 3.4 hp p.2 ↗ | 2BH1630, 60 Hz |
| Max. vacuum | -36 inch H2O p.2 ↗ | 2BH1630, 60 Hz |
| Max. pressure | 36 inch H2O p.2 ↗ | 2BH1630, 60 Hz |
| Sound pressure level | 64 dB(A) p.2 ↗ | 2BH1630, 60 Hz |
| Rated voltage | 230 / 400 V p.2 ↗ | 2BH1630, 50 Hz, Δ/Y, ATEX 3/2G |
| Rated current | 11.7 / 6.7 A p.2 ↗ | 2BH1630, 50 Hz, Δ/Y, ATEX 3/2G |
| Rated power | 4.4 hp p.2 ↗ | 2BH1630, 50 Hz, ATEX 3/2G |
| Max. vacuum | 92.332 inch H2O p.2 ↗ | 2BH1630, 50 Hz, ATEX 3/2G |
| Max. pressure | 92.3324 inch H2O p.2 ↗ | 2BH1630, 50 Hz, ATEX 3/2G |
| Sound pressure level | 71 dB(A) p.2 ↗ | 2BH1630, 50 Hz, ATEX 3/2G |
| Rated voltage | 460 V p.2 ↗ | 2BH1630, 60 Hz, Y, ATEX 3/2G |
| Rated current | 5.8 A p.2 ↗ | 2BH1630, 60 Hz, Y, ATEX 3/2G |
| Rated power | 4.4 hp p.2 ↗ | 2BH1630, 60 Hz, ATEX 3/2G |
| Max. vacuum | 76.275 inch H2O p.2 ↗ | 2BH1630, 60 Hz, ATEX 3/2G |
| Max. pressure | 76.2746 inch H2O p.2 ↗ | 2BH1630, 60 Hz, ATEX 3/2G |
| Sound pressure level | 71 dB(A) p.2 ↗ | 2BH1630, 60 Hz, ATEX 3/2G |
| Degree of protection | IP55 p.2 ↗ | 2BH1630, ATEX 3/2G |
Operating Limits
- Frequency tolerance: +/- 2 % max p.2 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Reference air temperature for performance curves: 59 F p.1 ↗
- Reference atmospheric pressure for performance curves: 29.92 inch Hg p.1 ↗
- Motor thermal class: F (IE3 efficiency class) p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BH1 | Series G-BH1 side channel blower |
| 5-7 p.2 ↗ | 630 | Size 630 |
| field 1 p.2 ↗ | 1 | Version field (fixed as printed) |
| field 2 p.2 ↗ | D / G | Voltage variant: D = 50 Hz Δ / 60 Hz Δ or Y; G = 60 Hz only (Y or Δ) |
| field 3 p.2 ↗ | 1 / 6 / 5 | Voltage code: 1 = 230Δ/400Y (50 Hz), 460Y (60 Hz); 6 = 400Δ/690Y (50 Hz), 460Δ (60 Hz); 5 = 500Δ (50 Hz), 575Δ (60 Hz) |
Related models
Elmo Rietschle 2BH1009
Elmo Rietschle 2BH1014
Elmo Rietschle 2BH1015
Elmo Rietschle 2BH1023
Elmo Rietschle 2BH1035
Elmo Rietschle 2BH1100
Elmo Rietschle 2BH1200
Elmo Rietschle 2BH1300
Elmo Rietschle 2BH1310
Elmo Rietschle 2BH1330
Elmo Rietschle 2BH1400
Elmo Rietschle 2BH1410
Elmo Rietschle 2BH1430
Elmo Rietschle 2BH1490
Elmo Rietschle 2BH1500
Elmo Rietschle 2BH1510
Elmo Rietschle 2BH1530
Elmo Rietschle 2BH1590
Elmo Rietschle 2BH1600
Elmo Rietschle 2BH1610
Elmo Rietschle 2BH1630
Elmo Rietschle 2BH1640
Elmo Rietschle 2BH1690
Elmo Rietschle 2BH1800
Elmo Rietschle 2BH1810
Elmo Rietschle 2BH1830
Elmo Rietschle 2BH1900
Elmo Rietschle 2BH1910
Elmo Rietschle 2BH1930
Elmo Rietschle 2BH1940
Elmo Rietschle 2BH1943