Technical Data Sheet — G-BH1 2BH1640 ATEX vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH1 640: side channel blower in ATEX configuration (G-BH1 N), usable as vacuum pump or compressor in continuous operation. ATEX categories 3GD and 3/2D as fixed-voltage machines for 50 and 60 Hz; category 3/2G available as 50 Hz or 60 Hz versions. Ordering code 2BH1…-1.□.□-Z with voltage/frequency field and ATEX variant Z=M34, M74, M71.

Technical Data

Parameter Value Condition
Rated voltage 400 / 690 V p.2 ↗ 2BH1640, 50 Hz, delta/star
Rated current 9,90 / 5,70 A p.2 ↗ 2BH1640, 50 Hz, delta/star
Rated power 7,4 hp p.2 ↗ 2BH1640, 50 Hz
Max. differential pressure (vacuum) -88 inch H2O p.2 ↗ 2BH1640, 50 Hz
Sound pressure level 76 dB(A) p.2 ↗ 2BH1640, 50 Hz
Weight 71 lbs p.2 ↗ 2BH1640, 50 Hz
Degree of protection IP55 p.2 ↗ 2BH1640
Rated voltage 460 V p.2 ↗ 2BH1640, 60 Hz, delta
Rated current 9,70 A p.2 ↗ 2BH1640, 60 Hz, delta
Rated power 8,4 hp p.2 ↗ 2BH1640, 60 Hz
Max. differential pressure (vacuum) -68 inch H2O p.2 ↗ 2BH1640, 60 Hz
Sound pressure level 60 dB(A) p.2 ↗ 2BH1640, 60 Hz
Weight 71 lbs p.2 ↗ 2BH1640, 60 Hz
Rated voltage 400 / 690 V p.2 ↗ 2BH1640, 50 Hz, delta/star, ATEX 3/2G
Rated current 13,1 / 7,3 A p.2 ↗ 2BH1640, 50 Hz, delta/star, ATEX 3/2G
Rated power 10,1 hp p.2 ↗ 2BH1640, 50 Hz, ATEX 3/2G
Max. differential pressure (vacuum) -96 inch H2O p.2 ↗ 2BH1640, 50 Hz, ATEX 3/2G
Sound pressure level 112 dB(A) p.2 ↗ 2BH1640, 50 Hz, ATEX 3/2G
Weight 71 lbs p.2 ↗ 2BH1640, 50 Hz, ATEX 3/2G
Rated voltage 460 V p.2 ↗ 2BH1640, 60 Hz, delta, ATEX 3/2G
Rated current 13,0 A p.2 ↗ 2BH1640, 60 Hz, delta, ATEX 3/2G
Rated power 11,5 hp p.2 ↗ 2BH1640, 60 Hz, ATEX 3/2G
Max. differential pressure (vacuum) -104 inch H2O p.2 ↗ 2BH1640, 60 Hz, ATEX 3/2G
Sound pressure level 100 dB(A) p.2 ↗ 2BH1640, 60 Hz, ATEX 3/2G
Weight 71 lbs p.2 ↗ 2BH1640, 60 Hz, ATEX 3/2G

Operating Limits

  • ATEX category 3GD / 3/2D availability: fixed voltage machines for 50 and 60 Hz p.1 ↗
  • ATEX category 3/2G availability: 50 Hz or 60 Hz versions only p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Reference air temperature for performance curves: 59 F p.1 ↗
  • Reference atmospheric pressure for performance curves: 29.92 inch Hg p.1 ↗
  • Degree of protection: IP55 p.2 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH1 Series G-BH1 side channel blower
5-7 p.2 ↗ 640 Size 640
field 1 p.2 ↗ 1 Version field (fixed 1 in printed code)
field 2 p.2 ↗ D / G Voltage connection variant: D = delta, G = star (subcategories i/o included)
field 3 p.2 ↗ 1 / 6 / 5 Voltage/frequency code: 1 = 230Δ/400Y (50 Hz) or 460Y (60 Hz); 6 = 400Δ/690Y (50 Hz) or 460Δ (60 Hz); 5 = 500Δ (50 Hz) or 575Δ (60 Hz)