Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — G-BH1 2BH1830 IE3 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH1 830: side channel blower with integrated frequency converter (VFD). Covers type 2BH1830 variants with order numbers 2BH1830-1A316, 2BH1830-1A326, 2BH1830-1AK06, 2BH1830-1AK16, 2BH1830-1AK26, plus integrated VFD types 2FC4xxx-1□□00 and accessories.

Technical Data

Parameter Value Condition
Rated motor voltage 370 V p.2 ↗ 2BH1830-1A316, 85 Hz
Rated motor current 21,5 A p.2 ↗ 2BH1830-1A316, 85 Hz
Rated motor power 10,2 kW p.2 ↗ 2BH1830-1A316, 85 Hz
Max. differential pressure, vacuum -70 mbar p.2 ↗ 2BH1830-1A316, 85 Hz
Max. differential pressure, pressure 50 mbar p.2 ↗ 2BH1830-1A316, 85 Hz
Sound pressure level 85 dB(A) p.2 ↗ 2BH1830-1A316, 85 Hz
Weight 128 kg p.2 ↗ 2BH1830-1A316
Rated motor voltage 380 V p.2 ↗ 2BH1830-1A326, 85 Hz
Rated motor current 27,4 A p.2 ↗ 2BH1830-1A326, 85 Hz
Rated motor power 14,0 kW p.2 ↗ 2BH1830-1A326, 85 Hz
Max. differential pressure, vacuum -230 mbar p.2 ↗ 2BH1830-1A326, 85 Hz
Max. differential pressure, pressure 170 mbar p.2 ↗ 2BH1830-1A326, 85 Hz
Sound pressure level 85 dB(A) p.2 ↗ 2BH1830-1A326, 85 Hz
Weight 159 kg p.2 ↗ 2BH1830-1A326
Rated motor voltage 400 V p.2 ↗ 2BH1830-1AK06, 85 Hz
Rated motor current 14,4 A p.2 ↗ 2BH1830-1AK06, 85 Hz
Rated motor power 7,5 kW p.2 ↗ 2BH1830-1AK06, 85 Hz
Max. differential pressure, vacuum -250 mbar p.2 ↗ 2BH1830-1AK06, 50 Hz
Max. differential pressure, pressure 230 mbar p.2 ↗ 2BH1830-1AK06, 50 Hz
Sound pressure level 78 dB(A) p.2 ↗ 2BH1830-1AK06, 50 Hz
Weight 117 kg p.2 ↗ 2BH1830-1AK06
Rated motor voltage 400 V p.2 ↗ 2BH1830-1AK16, 85 Hz
Rated motor current 20,0 A p.2 ↗ 2BH1830-1AK16, 85 Hz
Rated motor power 10,2 kW p.2 ↗ 2BH1830-1AK16, 85 Hz
Weight 127 kg p.2 ↗ 2BH1830-1AK16

Operating Limits

  • Max. ambient / suction temperature for stated pressure differences: 25 °C p.1 ↗
  • Min. mains voltage for frequency converter: 380 V p.1 ↗
  • Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
  • Min. pulse frequency for performance curves: 4 kHz p.1 ↗
  • Protection class: IP55 p.2 ↗
  • Insulation material class: F p.2 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH1830 Type designation: side channel blower 2BH1, size 830
VFD field 1 p.2 ↗ A-K VFD size letter (A, B, C, D, E, F, G, H, J, K) for 2FC4xxx-1□□00
VFD field 2 p.2 ↗ □□ Placeholder for VFD voltage / option code

Ordering Data

Ordering Code Part No. Variant / Code Applies To Note
2BH1830-1A316 p.2 ↗ 2BH1830-1A316 G 85 Hz, 370 V VFD type G
2BH1830-1A326 p.2 ↗ 2BH1830-1A326 G 85 Hz, 380 V VFD type G
2BH1830-1AK06 p.2 ↗ 2BH1830-1AK06 F 85 Hz, 400 V VFD type F
2BH1830-1AK16 p.2 ↗ 2BH1830-1AK16 G 85 Hz, 400 V VFD type G
2BH1830-1AK26 p.2 ↗ 2BH1830-1AK26 G 85 Hz, 400 V VFD type G