Data sheet 2BH1 930: side channel blower in ATEX configuration (G-BH1 N), 50 Hz and 60 Hz versions, ATEX categories 3GD, 3/2D and 3/2G, fixed voltage machines; other voltages available per ordering code 2BH1…-1.□.□-Z.

Technical Data

Parameter Value Condition
Rated voltage 400 / 690 V p.2 ↗ 2BH1930, 50 Hz, Δ/Y
Rated current 20.0 / 11.6 A p.2 ↗ 2BH1930, 50 Hz, Δ/Y
Power 14.8 hp p.2 ↗ 2BH1930, 50 Hz
Max. differential pressure (vacuum) -68 inch H2O p.2 ↗ 2BH1930, 50 Hz
Max. differential pressure (pressure) 64 inch H2O p.2 ↗ 2BH1930, 50 Hz
Sound pressure level 74 dB(A) p.2 ↗ 2BH1930, 50 Hz
Rated voltage 460 V p.2 ↗ 2BH1930, 60 Hz, Δ
Rated current 19.5 A p.2 ↗ 2BH1930, 60 Hz, Δ
Power 16.9 hp p.2 ↗ 2BH1930, 60 Hz
Max. differential pressure (vacuum) -44 inch H2O p.2 ↗ 2BH1930, 60 Hz
Max. differential pressure (pressure) 40 inch H2O p.2 ↗ 2BH1930, 60 Hz
Sound pressure level 74 dB(A) p.2 ↗ 2BH1930, 60 Hz
Weight 417 lbs p.2 ↗ 2BH1930
Degree of protection IP55 p.2 ↗ 2BH1930
ATEX category 3/2G p.2 ↗ 2BH1930
Motor thermal class F p.2 ↗ IE3

Operating Limits

  • Performance curve tolerance: ±10 % p.1 ↗
  • Reference air temperature: 59 °F p.1 ↗
  • Reference atmospheric pressure: 29.92 inch Hg p.1 ↗
  • Degree of protection: IP55 p.2 ↗

Type Code Decoder

Position Token Meaning
1-5 p.2 ↗ 2BH1… Type / series (side channel blower G-BH1)
field 1 p.2 ↗ 1 Version field (fixed as printed)
field 2 p.2 ↗ □ Voltage connection code: D = Δ connection, G = Y connection
field 3 p.2 ↗ □ Voltage code: 1 = 230 Δ/400 Y (50 Hz) / 460 Y (60 Hz); 6 = 400 Δ/690 Y (50 Hz) / 460 Δ (60 Hz); 5 = 500 Δ (50 Hz) / 575 Δ (60 Hz)