Technical Data Sheet — G-BH1 2BH1943 IE3 side channel blower (EN)
Technical Reference Summary
Covered Models & Document Scope
Data sheet 2BH1 943: side channel blower with integrated frequency converter (IP55) for wall mounting. Covers blower types 2BH1943-1GK36 and 2BH1943-1GK46 at 37/50/60/72 Hz, frequency converter sizes A–K (2FC4...-1□□00), and accessories (MMI handheld, USB adaptor cable, pressure/vacuum sensors).
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Max. differential pressure (vacuum) | -250 mbar p.2 ↗ | 2BH1943-1GK36, 37 Hz |
| Max. differential pressure (pressure) | 240 mbar p.2 ↗ | 2BH1943-1GK36, 37 Hz |
| Sound pressure level | 73 dB(A) p.2 ↗ | 2BH1943-1GK36, 37 Hz |
| Max. differential pressure (vacuum) | -250 mbar p.2 ↗ | 2BH1943-1GK36, 50 Hz |
| Max. differential pressure (pressure) | 230 mbar p.2 ↗ | 2BH1943-1GK36, 50 Hz |
| Sound pressure level | 73 dB(A) p.2 ↗ | 2BH1943-1GK36, 50 Hz |
| Max. differential pressure (vacuum) | -190 mbar p.2 ↗ | 2BH1943-1GK36, 60 Hz |
| Max. differential pressure (pressure) | 180 mbar p.2 ↗ | 2BH1943-1GK36, 60 Hz |
| Sound pressure level | 77 dB(A) p.2 ↗ | 2BH1943-1GK36, 60 Hz |
| Rated mains voltage | 330 V p.2 ↗ | 2BH1943-1GK36, 72 Hz, delta |
| Rated motor current | 79.0 A p.2 ↗ | 2BH1943-1GK36, 72 Hz, delta |
| Rated motor power | 35.0 kW p.2 ↗ | 2BH1943-1GK36, 72 Hz |
| Max. differential pressure (vacuum) | -130 mbar p.2 ↗ | 2BH1943-1GK36, 72 Hz |
| Max. differential pressure (pressure) | 120 mbar p.2 ↗ | 2BH1943-1GK36, 72 Hz |
| Sound pressure level | 82 dB(A) p.2 ↗ | 2BH1943-1GK36, 72 Hz |
| Max. differential pressure (vacuum) | -310 mbar p.2 ↗ | 2BH1943-1GK46, 37 Hz |
| Max. differential pressure (pressure) | 300 mbar p.2 ↗ | 2BH1943-1GK46, 37 Hz |
| Sound pressure level | 73 dB(A) p.2 ↗ | 2BH1943-1GK46, 37 Hz |
| Max. differential pressure (vacuum) | -310 mbar p.2 ↗ | 2BH1943-1GK46, 50 Hz |
| Max. differential pressure (pressure) | 280 mbar p.2 ↗ | 2BH1943-1GK46, 50 Hz |
| Sound pressure level | 73 dB(A) p.2 ↗ | 2BH1943-1GK46, 50 Hz |
| Max. differential pressure (vacuum) | -270 mbar p.2 ↗ | 2BH1943-1GK46, 60 Hz |
| Max. differential pressure (pressure) | 230 mbar p.2 ↗ | 2BH1943-1GK46, 60 Hz |
| Sound pressure level | 77 dB(A) p.2 ↗ | 2BH1943-1GK46, 60 Hz |
| Rated motor power | 35.0 kW p.2 ↗ | 2BH1943-1GK46, 72 Hz |
Operating Limits
- Max. suction and ambient temperature for stated pressure differences: 25 °C p.1 ↗
- Performance curve tolerance: ±10 % p.1 ↗
- Reference air temperature for performance curves: 15 °C p.1 ↗
- Reference atmospheric pressure for performance curves: 1013 mbar p.1 ↗
- Minimum frequency converter pulse frequency: 4 kHz p.1 ↗
- Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-6 p.2 ↗ | 2BH194 | Side channel blower series 2BH1, size 943 |
| 8-11 p.2 ↗ | 1GK3 / 1GK4 | Motor/impeller variant: 1GK36 or 1GK46 |
| converter field 1 p.2 ↗ | A–K | Frequency converter size (2FC4...-1□□00), see converter table |
| converter field 2-3 p.2 ↗ | □□ | Voltage/frequency option placeholders of the frequency converter |
Related models
Elmo Rietschle 2BH1009
Elmo Rietschle 2BH1014
Elmo Rietschle 2BH1015
Elmo Rietschle 2BH1023
Elmo Rietschle 2BH1035
Elmo Rietschle 2BH1100
Elmo Rietschle 2BH1200
Elmo Rietschle 2BH1300
Elmo Rietschle 2BH1310
Elmo Rietschle 2BH1330
Elmo Rietschle 2BH1400
Elmo Rietschle 2BH1410
Elmo Rietschle 2BH1430
Elmo Rietschle 2BH1490
Elmo Rietschle 2BH1500
Elmo Rietschle 2BH1510
Elmo Rietschle 2BH1530
Elmo Rietschle 2BH1590
Elmo Rietschle 2BH1600
Elmo Rietschle 2BH1610
Elmo Rietschle 2BH1630
Elmo Rietschle 2BH1640
Elmo Rietschle 2BH1690
Elmo Rietschle 2BH1800
Elmo Rietschle 2BH1810
Elmo Rietschle 2BH1830
Elmo Rietschle 2BH1900
Elmo Rietschle 2BH1910
Elmo Rietschle 2BH1930
Elmo Rietschle 2BH1940
Elmo Rietschle 2BH1943