Technical Data Sheet — G-BH1 2BH1330 IE3 side channel blower (EN)
Technical Reference Summary
Covered Models & Document Scope
Data sheet 2BH1 330: side channel blower with integrated frequency converter (IP55), 2BH1330-1A221 and 2BH1330-1AP16 variants; VFD types A–K (2FC4xxx-1□□00) and VFD accessories.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated voltage | 345 V p.2 ↗ | 2BH1330-1A221, 87 Hz, delta |
| Rated current | 2,8 A p.2 ↗ | 2BH1330-1A221, 87 Hz, delta |
| Rated motor power | 0,95 kW p.2 ↗ | 2BH1330-1A221, 87 Hz |
| Max. differential pressure, vacuum | -130 mbar p.2 ↗ | 2BH1330-1A221, 87 Hz |
| Max. differential pressure, pressure | 120 mbar p.2 ↗ | 2BH1330-1A221, 87 Hz |
| Sound pressure level | 62 dB(A) p.2 ↗ | 2BH1330-1A221, 87 Hz |
| Weight | 16 kg p.2 ↗ | 2BH1330-1A221, 87 Hz |
| Max. differential pressure, vacuum | -80 mbar p.2 ↗ | 2BH1330-1A221, 37 Hz |
| Max. differential pressure, pressure | 90 mbar p.2 ↗ | 2BH1330-1A221, 37 Hz |
| Max. differential pressure, vacuum | -110 mbar p.2 ↗ | 2BH1330-1A221, 50 Hz |
| Max. differential pressure, pressure | 110 mbar p.2 ↗ | 2BH1330-1A221, 50 Hz |
| Sound pressure level | 53 dB(A) p.2 ↗ | 2BH1330-1A221, 50 Hz |
| Weight | 11 kg p.2 ↗ | 2BH1330-1A221, 50 Hz |
| Max. differential pressure, vacuum | -90 mbar p.2 ↗ | 2BH1330-1A221, 60 Hz |
| Max. differential pressure, pressure | 90 mbar p.2 ↗ | 2BH1330-1A221, 60 Hz |
| Sound pressure level | 56 dB(A) p.2 ↗ | 2BH1330-1A221, 60 Hz |
| Rated voltage | 400 V p.2 ↗ | 2BH1330-1AP16, 87 Hz |
| Rated current | 1,65 A p.2 ↗ | 2BH1330-1AP16, 87 Hz |
| Rated motor power | 0,64 kW p.2 ↗ | 2BH1330-1AP16, 87 Hz |
| Max. differential pressure, vacuum | -70 mbar p.2 ↗ | 2BH1330-1AP16, 87 Hz |
| Max. differential pressure, pressure | 60 mbar p.2 ↗ | 2BH1330-1AP16, 87 Hz |
Operating Limits
- Max. suction and ambient temperature for stated pressure differences: 25 °C p.1 ↗
- Min. mains voltage for frequency converter: 380 V p.1 ↗
- Min. pulse frequency for performance curves: 4 kHz p.1 ↗
- Performance curve tolerance: ±10 % p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-6 p.2 ↗ | 2BH1330 | Blower type/size designation |
| 7-11 p.2 ↗ | 1A221 | Motor/voltage variant (345 V, 87 Hz, delta) |
| 7-11 p.2 ↗ | 1AP16 | Motor/voltage variant (400 V, 87 Hz) |
| VFD type field p.2 ↗ | A–K | Frequency converter size (2FC4xxx-1□□00) |
Related models
Elmo Rietschle 2BH1009
Elmo Rietschle 2BH1014
Elmo Rietschle 2BH1015
Elmo Rietschle 2BH1023
Elmo Rietschle 2BH1035
Elmo Rietschle 2BH1100
Elmo Rietschle 2BH1200
Elmo Rietschle 2BH1300
Elmo Rietschle 2BH1310
Elmo Rietschle 2BH1330
Elmo Rietschle 2BH1400
Elmo Rietschle 2BH1410
Elmo Rietschle 2BH1430
Elmo Rietschle 2BH1490
Elmo Rietschle 2BH1500
Elmo Rietschle 2BH1510
Elmo Rietschle 2BH1530
Elmo Rietschle 2BH1590
Elmo Rietschle 2BH1600
Elmo Rietschle 2BH1610
Elmo Rietschle 2BH1630
Elmo Rietschle 2BH1640
Elmo Rietschle 2BH1690
Elmo Rietschle 2BH1800
Elmo Rietschle 2BH1810
Elmo Rietschle 2BH1830
Elmo Rietschle 2BH1900
Elmo Rietschle 2BH1910
Elmo Rietschle 2BH1930
Elmo Rietschle 2BH1940
Elmo Rietschle 2BH1943