Data sheet 2BH1 410: side channel blower in ATEX configuration (G-BH1 N), usable as vacuum pump and compressor in continuous operation. ATEX categories 3GD and 3/2D as fixed-voltage machines for 50 and 60 Hz; category 3/2G available only as 50 Hz or 60 Hz versions.

Technical Data

Parameter Value Condition
Rated voltage 230 Δ / 400 Y V p.2 ↗ 2BH1410, 50 Hz
Rated current 7.3 Δ / 4.2 Y A p.2 ↗ 2BH1410, 50 Hz
Rated power 3.0 hp p.2 ↗ 2BH1410, 50 Hz
Max. vacuum -120 inch H2O p.2 ↗ 2BH1410, 50 Hz
Max. differential pressure 153 inch H2O p.2 ↗ 2BH1410, 50 Hz
Sound pressure level 67 dB(A) p.2 ↗ 2BH1410, 50 Hz
Weight 67 lbs p.2 ↗ 2BH1410, 50 Hz
Degree of protection IP0 p.2 ↗ 2BH1410, 50 Hz
ATEX category 3/2G p.2 ↗ 2BH1410, 50 Hz
Rated voltage 460 Y V p.2 ↗ 2BH1410, 60 Hz
Rated current 4.2 Y A p.2 ↗ 2BH1410, 60 Hz
Rated power 3.4 hp p.2 ↗ 2BH1410, 60 Hz
Max. vacuum -132 inch H2O p.2 ↗ 2BH1410, 60 Hz
Max. differential pressure 153 inch H2O p.2 ↗ 2BH1410, 60 Hz
Sound pressure level 67 dB(A) p.2 ↗ 2BH1410, 60 Hz
Weight 67 lbs p.2 ↗ 2BH1410, 60 Hz
Degree of protection IP0 p.2 ↗ 2BH1410, 60 Hz
ATEX category 3/2G p.2 ↗ 2BH1410, 60 Hz

Operating Limits

  • ATEX category availability: 3GD and 3/2D as fixed-voltage machines for 50 and 60 Hz; 3/2G only 50 Hz or 60 Hz versions p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Reference air temperature: 59 F p.1 ↗
  • Reference atmospheric pressure: 29.92 inch Hg p.1 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH1 Series G-BH1 side channel blower
5-7 p.2 ↗ 410 Size 410
field 1 p.2 ↗ D / G ATEX subcategory: D = inside (i), G = outside (o)
field 2 p.2 ↗ 1 / 5 / 6 Voltage code: 1 = 230 Δ/400 Y (50 Hz) or 460 Y (60 Hz); 5 = 500 Δ (50 Hz) or 575 Δ (60 Hz); 6 = 400 Δ/690 Y (50 Hz) or 460 Δ (60 Hz)
field 3 p.2 ↗ M34 / M74 / M71 ATEX category: M34 = 3/2D, M74 = 3GD, M71 = 3/2G