Technical Data Sheet — G-BH1 2BH1410 IE3 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH1 410 (Edition 01/2019): side channel blower with integrated frequency converter, size 2BH1410; variants 2BH1410-1H346 (380 V, 87 Hz, 4.30 kW), 2BH1410-1HK36 (380 V, 50/60 Hz, 2.90 kW), 2BH1410-1HK46 (400 V, 50/60 Hz, 4.30 kW); frequency converter modules 2FC4xxx-1□□00 (sizes A–K) and accessories (MMI handheld, USB adaptor cable, differential pressure transmitters).

Technical Data

Parameter Value Condition
Rated mains voltage 380 V p.2 ↗ 2BH1410-1H346, 87 Hz
Rated motor current 8,8 A p.2 ↗ 2BH1410-1H346, 87 Hz
Rated motor power 4,30 kW p.2 ↗ 2BH1410-1H346, 87 Hz
Max. differential pressure (vacuum) -410 mbar p.2 ↗ 2BH1410-1H346, 87 Hz
Max. differential pressure (pressure) 360 mbar p.2 ↗ 2BH1410-1H346, 87 Hz
Sound pressure level 78 dB(A) p.2 ↗ 2BH1410-1H346, 87 Hz
Weight 43 kg p.2 ↗ 2BH1410-1H346, 87 Hz
Rated mains voltage 380 V p.2 ↗ 2BH1410-1HK36, 50/60 Hz
Rated motor power 2,90 kW p.2 ↗ 2BH1410-1HK36, 50/60 Hz
Max. differential pressure (vacuum) -320 mbar p.2 ↗ 2BH1410-1HK36, 50 Hz
Max. differential pressure (pressure) 420 mbar p.2 ↗ 2BH1410-1HK36, 50 Hz
Sound pressure level 67 dB(A) p.2 ↗ 2BH1410-1HK36, 50 Hz
Weight 36 kg p.2 ↗ 2BH1410-1HK36, 50/60 Hz
Rated mains voltage 400 V p.2 ↗ 2BH1410-1HK46, 50/60 Hz
Rated motor current 8,7 A p.2 ↗ 2BH1410-1HK46, 87 Hz
Rated motor power 4,30 kW p.2 ↗ 2BH1410-1HK46, 50/60 Hz
Max. differential pressure (vacuum) -350 mbar p.2 ↗ 2BH1410-1HK46, 60 Hz
Max. differential pressure (pressure) 440 mbar p.2 ↗ 2BH1410-1HK46, 60 Hz
Sound pressure level 77 dB(A) p.2 ↗ 2BH1410-1HK46, 60 Hz
Weight 38 kg p.2 ↗ 2BH1410-1HK46, 50/60 Hz
Rated mains voltage (frequency converter) 380 V p.1 ↗ minimum mains voltage for frequency converter operation
Rated voltage/frequency set point 345 V / 87 Hz p.1 ↗ frequency converter operation, delta connection
Minimum pulse frequency 4 kHz p.1 ↗ frequency converter operation
Suction and ambient temperature up to 25 °C p.1 ↗ validity of total pressure differences
Performance curve tolerance ± 10 % p.1 ↗ air at 15 °C, 1013 mbar

Operating Limits

  • Suction and ambient temperature for rated pressure data: up to 25 °C p.1 ↗
  • Minimum mains voltage for frequency converter operation: 380 V p.1 ↗
  • Minimum pulse frequency of frequency converter: 4 kHz p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH141 Side channel blower series 2BH1, size 410
8-9 p.2 ↗ 1H Motor variant field (1H = standard motor)
field 1 p.2 ↗ A–K Frequency converter module size (2FC4xxx-1□□00)
field 2-3 p.2 ↗ □□ Frequency converter option placeholders (not specified in this document)

Ordering Data

Ordering Code Part No. Variant / Code Applies To Note
2BH1410-1H346 p.2 ↗ 2BH1410-1H346 380 V, 87 Hz, 4.30 kW Blower with frequency-converter motor
2BH1410-1HK36 p.2 ↗ 2BH1410-1HK36 380 V, 50/60 Hz, 2.90 kW Blower with 50/60 Hz motor
2BH1410-1HK46 p.2 ↗ 2BH1410-1HK46 400 V, 50/60 Hz, 4.30 kW Blower with 50/60 Hz motor