Technical Data Sheet — G-BH1 2BH1500 ATEX vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Data sheet 2BH1 500: side channel blower in ATEX configuration (G-BH1 N), categories 3GD, 3/2D and 3/2G, fixed-voltage machines for 50 Hz and 60 Hz; ordering code 2BH1…-1.□.□-Z with voltage/ATEX substitutions.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated voltage | 400 / 690 Y V p.2 ↗ | 2BH1500, 50 Hz, 3/2D, 3GD |
| Rated current | 3,00 / 1,73 Y A p.2 ↗ | 2BH1500, 50 Hz, 3/2D, 3GD |
| Power | 2,0 hp p.2 ↗ | 2BH1500, 50 Hz, 3/2D, 3GD |
| Max. differential pressure (vacuum) | -88 inch H2O p.2 ↗ | 2BH1500, 50 Hz, 3/2D, 3GD |
| Max. differential pressure (pressure) | 72 inch H2O p.2 ↗ | 2BH1500, 50 Hz, 3/2D, 3GD |
| Sound level | 64 dB(A) p.2 ↗ | 2BH1500, 50 Hz, 3/2D, 3GD |
| Weight | 69 lbs p.2 ↗ | 2BH1500, 50 Hz, 3/2D, 3GD |
| Degree of protection | IP55 p.2 ↗ | 2BH1500, 50 Hz, 3/2D, 3GD |
| ATEX category | 3/2G p.2 ↗ | 2BH1500, 50 Hz, 3/2G |
| Rated voltage | 460 V p.2 ↗ | 2BH1500, 60 Hz, 3/2D, 3GD |
| Rated current | 2,95 A p.2 ↗ | 2BH1500, 60 Hz, 3/2D, 3GD |
| Power | 2,3 hp p.2 ↗ | 2BH1500, 60 Hz, 3/2D, 3GD |
| Max. differential pressure (vacuum) | -68 inch H2O p.2 ↗ | 2BH1500, 60 Hz, 3/2D, 3GD |
| Max. differential pressure (pressure) | 68 inch H2O p.2 ↗ | 2BH1500, 60 Hz, 3/2D, 3GD |
| Sound level | 64 dB(A) p.2 ↗ | 2BH1500, 60 Hz, 3/2D, 3GD |
| Weight | 69 lbs p.2 ↗ | 2BH1500, 60 Hz, 3/2D, 3GD |
| Degree of protection | IP55 p.2 ↗ | 2BH1500, 60 Hz, 3/2D, 3GD |
| ATEX category | 3/2G p.2 ↗ | 2BH1500, 60 Hz, 3/2G |
Operating Limits
- Performance curve tolerance: ± 10 % p.1 ↗
- Reference air temperature: 59 F p.1 ↗
- Reference atmospheric pressure: 29.92 inch Hg p.1 ↗
- Degree of protection: IP55 p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BH1 | Series / type: side channel blower G-BH1 |
| 5-7 p.2 ↗ | 500 | Size designation (2BH1 500) |
| field 1 p.2 ↗ | 1 | Version / generation field |
| field 2 p.2 ↗ | D | Voltage connection code: D = Δ connection (230 Δ/400 Y, 400 Δ/690 Y, 500 Δ); G = Y connection (460 Y, 575 Δ) |
| field 3 p.2 ↗ | 1 | Voltage variant: 230 Δ/400 Y (50 Hz) / 460 Y (60 Hz) |
| field 3 p.2 ↗ | 6 | Voltage variant: 400 Δ/690 Y (50 Hz) / 460 Δ (60 Hz) |
| field 3 p.2 ↗ | 5 | Voltage variant: 500 Δ (50 Hz) / 575 Δ (60 Hz) |
Related models
Elmo Rietschle 2BH1009
Elmo Rietschle 2BH1014
Elmo Rietschle 2BH1015
Elmo Rietschle 2BH1023
Elmo Rietschle 2BH1035
Elmo Rietschle 2BH1100
Elmo Rietschle 2BH1200
Elmo Rietschle 2BH1300
Elmo Rietschle 2BH1310
Elmo Rietschle 2BH1330
Elmo Rietschle 2BH1400
Elmo Rietschle 2BH1410
Elmo Rietschle 2BH1430
Elmo Rietschle 2BH1490
Elmo Rietschle 2BH1500
Elmo Rietschle 2BH1510
Elmo Rietschle 2BH1530
Elmo Rietschle 2BH1590
Elmo Rietschle 2BH1600
Elmo Rietschle 2BH1610
Elmo Rietschle 2BH1630
Elmo Rietschle 2BH1640
Elmo Rietschle 2BH1690
Elmo Rietschle 2BH1800
Elmo Rietschle 2BH1810
Elmo Rietschle 2BH1830
Elmo Rietschle 2BH1900
Elmo Rietschle 2BH1910
Elmo Rietschle 2BH1930
Elmo Rietschle 2BH1940
Elmo Rietschle 2BH1943