Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — G-BH1 2BH1600 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Side channel blower G-BH1, data sheet 2BH1 600. Covers sizes 4 and 5 (2BH1600-1AH26, 2BH1600-1AH36, 2BH1600-1AC23, 2BH1600-1AC33) at 50 Hz and 60 Hz, with dual-voltage D/Y windings, fixed-voltage and VFD motor variants.

Technical Data

Parameter Value Condition
Rated pressure (vacuum) -260 mbar p.2 ↗ 2BH1600-1AH26, size 4, 50 Hz
Rated pressure (vacuum) -240 mbar p.2 ↗ 2BH1600-1AH26, size 4, 60 Hz
Rated pressure (vacuum) -290 mbar p.2 ↗ 2BH1600-1AH36, size 5, 50 Hz
Rated pressure (vacuum) -320 mbar p.2 ↗ 2BH1600-1AH36, size 5, 60 Hz
Max. differential pressure (pressure) 270 mbar p.2 ↗ 2BH1600-1AH26, size 4, 50 Hz
Max. differential pressure (pressure) 230 mbar p.2 ↗ 2BH1600-1AH26, size 4, 60 Hz
Max. differential pressure (pressure) 360 mbar p.2 ↗ 2BH1600-1AH36, size 5, 50 Hz
Max. differential pressure (pressure) 310 mbar p.2 ↗ 2BH1600-1AH36, size 5, 60 Hz
Voltage 200-240 D / 345-415 Y V p.2 ↗ 2BH1600-1AH26, size 4, 50 Hz
Voltage 220-275 D / 380-480 Y V p.2 ↗ 2BH1600-1AH26, size 4, 60 Hz
Voltage 200-240 D / 345-415 Y V p.2 ↗ 2BH1600-1AH36, size 5, 50 Hz
Voltage 220-275 D / 380-480 Y V p.2 ↗ 2BH1600-1AH36, size 5, 60 Hz
Current 12,5 D / 7,2 Y A p.2 ↗ 2BH1600-1AH26, size 4, 50 Hz
Current 12,6 D / 7,3 Y A p.2 ↗ 2BH1600-1AH26, size 4, 60 Hz
Current 15,6 D / 9,0 Y A p.2 ↗ 2BH1600-1AH36, size 5, 50 Hz
Current 15,6 D / 9,0 Y A p.2 ↗ 2BH1600-1AH36, size 5, 60 Hz
Power 3,0 kW p.2 ↗ 2BH1600-1AH26, size 4, 50 Hz
Power 3,45 kW p.2 ↗ 2BH1600-1AH26, size 4, 60 Hz
Power 4,0 kW p.2 ↗ 2BH1600-1AH36, size 5, 50 Hz
Power 4,6 kW p.2 ↗ 2BH1600-1AH36, size 5, 60 Hz
Sound pressure level 71 dB(A) p.2 ↗ 2BH1600-1AH26, size 4, 50 Hz
Sound pressure level 75 dB(A) p.2 ↗ 2BH1600-1AH26, size 4, 60 Hz
Sound pressure level 71 dB(A) p.2 ↗ 2BH1600-1AH36, size 5, 50 Hz
Sound pressure level 75 dB(A) p.2 ↗ 2BH1600-1AH36, size 5, 60 Hz
Weight 37 kg p.2 ↗ 2BH1600-1AH26, size 4

Operating Limits

  • Max. suction and ambient temperature for stated total pressure differences: 25 °C p.1 ↗
  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Frequency tolerance: +/- 2 % p.2 ↗
  • Max. converter input voltage for standard motor insulation: 460 V p.2 ↗

Type Code Decoder

Position Token Meaning
1-7 p.2 ↗ 2BH1600 Series G-BH1 side channel blower, size 600