Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — G-BH1 2BH1830 ATEX vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH1 830: side channel blower in ATEX configuration (G-BH1 N), 2BH1830 series. ATEX categories 3GD, 3/2D and 3/2G; fixed-voltage machines for 50 Hz and 60 Hz; 3/2G available only as 50 Hz or 60 Hz versions.

Technical Data

Parameter Value Condition
Rated voltage 400 / 690 V p.2 ↗ 2BH1830, 50 Hz, delta/Y
Rated current 13,1 / 7,6 A p.2 ↗ 2BH1830, 50 Hz, delta/Y
Power 10,1 hp p.2 ↗ 2BH1830, 50 Hz
Max. vacuum -116 inch H2O p.2 ↗ 2BH1830, 50 Hz
Max. differential pressure 120 inch H2O p.2 ↗ 2BH1830, 50 Hz
Sound pressure level 79 dB(A) p.2 ↗ 2BH1830, 50 Hz
Rated voltage 460 V p.2 ↗ 2BH1830, 60 Hz, delta
Rated current 13,0 A p.2 ↗ 2BH1830, 60 Hz, delta
Power 11,5 hp p.2 ↗ 2BH1830, 60 Hz
Max. vacuum -112 inch H2O p.2 ↗ 2BH1830, 60 Hz
Max. differential pressure 100 inch H2O p.2 ↗ 2BH1830, 60 Hz
Sound pressure level 79 dB(A) p.2 ↗ 2BH1830, 60 Hz
Rated voltage 460 V p.2 ↗ 2BH1830-1AG21-Z, 60 Hz, delta
Rated current 8,9 A p.2 ↗ 2BH1830-1AG21-Z, 60 Hz, delta
Power 7,4 hp p.2 ↗ 2BH1830-1AG21-Z, 60 Hz
Max. vacuum -52 inch H2O p.2 ↗ 2BH1830-1AG21-Z, 60 Hz
Max. differential pressure 48 inch H2O p.2 ↗ 2BH1830-1AG21-Z, 60 Hz
Sound pressure level 79 dB(A) p.2 ↗ 2BH1830-1AG21-Z, 60 Hz

Operating Limits

  • ATEX categories available: 3GD, 3/2D, 3/2G p.1 ↗
  • ATEX 3/2G frequency availability: 50 Hz or 60 Hz only p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Reference air temperature: 59 F p.1 ↗
  • Reference atmospheric pressure: 29.92 inch Hg p.1 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH1 Series / type: side channel blower G-BH1
5-8 p.2 ↗ 830 Size 830
field 1 p.2 ↗ 1 Voltage code: 230 delta / 400 Y (50 Hz), 460 Y (60 Hz)
field 1 p.2 ↗ 6 Voltage code: 400 delta / 690 Y (50 Hz), 460 delta (60 Hz)
field 1 p.2 ↗ 5 Voltage code: 500 delta (50 Hz), 575 delta (60 Hz)
field 2 p.2 ↗ D Connection: delta (3/2D, 3GD)
field 2 p.2 ↗ G Connection: Y (3/2G)
field 3 p.2 ↗ 1 ATEX motor variant 1
field 3 p.2 ↗ 6 ATEX motor variant 6
field 3 p.2 ↗ 5 ATEX motor variant 5