Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — G-BH1 2BH1910 IE3 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH1 910 (Edition 10/2020): side channel blower with integrated frequency converter, sizes 2BH1910-1H314, -1H324, -1HK16, -1HK26, -1HK36, -1HK46; 50 Hz and 60 Hz data; frequency converter types 2FC4xxx-1□□00 (A–K) for wall mounting.

Technical Data

Parameter Value Condition
Rated motor voltage 400 V p.2 ↗ 2BH1910-1H314, 50 Hz
Rated motor current 32,3 A p.2 ↗ 2BH1910-1H314, 50 Hz
Rated motor power 17,4 kW p.2 ↗ 2BH1910-1H314, 50 Hz
Max. differential pressure, vacuum -130 mbar p.2 ↗ 2BH1910-1H314, 50 Hz
Max. differential pressure, pressure 110 mbar p.2 ↗ 2BH1910-1H314, 50 Hz
Sound pressure level 81 dB(A) p.2 ↗ 2BH1910-1H314, 50 Hz
Weight 315 kg p.2 ↗ 2BH1910-1H314
Rated motor current 44,5 A p.2 ↗ 2BH1910-1H324, 50 Hz
Rated motor power 23,9 kW p.2 ↗ 2BH1910-1H324, 50 Hz
Max. differential pressure, vacuum -300 mbar p.2 ↗ 2BH1910-1H324, 50 Hz
Max. differential pressure, pressure 240 mbar p.2 ↗ 2BH1910-1H324, 50 Hz
Weight 325 kg p.2 ↗ 2BH1910-1H324
Max. differential pressure, vacuum -400 mbar p.2 ↗ 2BH1910-1HK26, 50 Hz
Max. differential pressure, pressure 360 mbar p.2 ↗ 2BH1910-1HK26, 50 Hz
Max. differential pressure, vacuum -440 mbar p.2 ↗ 2BH1910-1HK36, 50 Hz
Max. differential pressure, pressure 480 mbar p.2 ↗ 2BH1910-1HK36, 50 Hz
Max. differential pressure, vacuum -440 mbar p.2 ↗ 2BH1910-1HK46, 50 Hz
Max. differential pressure, pressure 590 mbar p.2 ↗ 2BH1910-1HK46, 50 Hz
Rated motor power 35,0 kW p.2 ↗ 2BH1910-1HK46, 50 Hz
Rated motor voltage 330 V p.2 ↗ 2BH1910-1HK46, 60 Hz
Rated motor current 79,0 A p.2 ↗ 2BH1910-1HK46, 60 Hz
Max. differential pressure, vacuum -460 mbar p.2 ↗ 2BH1910-1HK46, 60 Hz
Max. differential pressure, pressure 460 mbar p.2 ↗ 2BH1910-1HK46, 60 Hz
Sound pressure level 81 dB(A) p.2 ↗ 2BH1910-1HK46, 60 Hz
Frequency converter rated mains voltage 380 V p.1 ↗ minimum, frequency converter operation

Operating Limits

  • Suction and ambient temperature for stated pressure differences: up to 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Frequency converter minimum pulse frequency: 4 kHz p.1 ↗
  • Frequency converter rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
  • Frequency converter minimum mains voltage: 380 V p.1 ↗
  • Frequency converter protection class: IP55 p.2 ↗

Type Code Decoder

Position Token Meaning
1-7 p.2 ↗ 2BH1910 Type/size: side channel blower 2BH1 910
9-10 p.2 ↗ 1H Motor variant field
frequency converter field 1 p.2 ↗ A-K Frequency converter size/power class (A 1,5 kW … K 22,0 kW)
frequency converter field 2-3 p.2 ↗ □□ Placeholder for voltage/frequency variant of converter
frequency converter suffix p.2 ↗ 00 Fixed suffix of converter order code