Technical Data Sheet — G-BH1 2BH1940 IE3 side channel blower (EN)
Technical Reference Summary
Covered Models & Document Scope
Data sheet 2BH1 940: side channel blower with integrated frequency converter (VFD), type 2BH1 940, 3~ 50/60 Hz, IP55, insulation class F, UL 1450 / CAN/CSA C22.2 No. 68-09 (E225239). Covers 50 Hz and 60 Hz operation and VFD types A–K (2FC4xxx).
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated motor voltage | 330 D V p.2 ↗ | 2BH1 940, 72 Hz, VFD operation |
| Rated motor current | 65,3 D A p.2 ↗ | 2BH1 940, 72 Hz, VFD operation |
| Rated motor power | 29,4 kW p.2 ↗ | 2BH1 940, 72 Hz, VFD operation |
| Max. differential pressure, vacuum | -100 mbar p.2 ↗ | 2BH1 940, 72 Hz, VFD operation |
| Max. differential pressure, pressure | 80 mbar p.2 ↗ | 2BH1 940, 72 Hz, VFD operation |
| Sound pressure level | 82 dB(A) p.2 ↗ | 2BH1 940, 72 Hz, VFD operation |
| Max. differential pressure, vacuum | -220 mbar p.2 ↗ | 2BH1 940, 50 Hz |
| Max. differential pressure, pressure | 200 mbar p.2 ↗ | 2BH1 940, 50 Hz |
| Sound pressure level | 73 dB(A) p.2 ↗ | 2BH1 940, 50 Hz |
| Weight | 80/81 kg p.2 ↗ | 2BH1 940, 50 Hz |
| Max. differential pressure, vacuum | -160 mbar p.2 ↗ | 2BH1 940, 60 Hz |
| Max. differential pressure, pressure | 150 mbar p.2 ↗ | 2BH1 940, 60 Hz |
| Sound pressure level | 77 dB(A) p.2 ↗ | 2BH1 940, 60 Hz |
| Max. differential pressure, vacuum | -270 mbar p.2 ↗ | 2BH1 940, 50 Hz, variant 2 |
| Max. differential pressure, pressure | 300 mbar p.2 ↗ | 2BH1 940, 50 Hz, variant 2 |
| Max. differential pressure, vacuum | -300 mbar p.2 ↗ | 2BH1 940, 50 Hz, variant 2 |
| Max. differential pressure, pressure | 300 mbar p.2 ↗ | 2BH1 940, 50 Hz, variant 2 |
| Max. differential pressure, vacuum | -280 mbar p.2 ↗ | 2BH1 940, 60 Hz, variant 2 |
| Max. differential pressure, pressure | 250 mbar p.2 ↗ | 2BH1 940, 60 Hz, variant 2 |
| Sound pressure level | 77 dB(A) p.2 ↗ | 2BH1 940, 60 Hz, variant 2 |
| Rated motor voltage | 330 D V p.2 ↗ | 2BH1 940, 72 Hz, variant 2 |
| Rated motor current | 79,0 D A p.2 ↗ | 2BH1 940, 72 Hz, variant 2 |
| Rated motor power | 35,0 kW p.2 ↗ | 2BH1 940, 72 Hz, variant 2 |
| Max. differential pressure, vacuum | -200 mbar p.2 ↗ | 2BH1 940, 72 Hz, variant 2 |
| Max. differential pressure, pressure | 150 mbar p.2 ↗ | 2BH1 940, 72 Hz, variant 2 |
Operating Limits
- Max. ambient/suction temperature for stated pressure differences: 25 °C p.1 ↗
- Performance curve tolerance: ±10 % p.1 ↗
- Minimum frequency converter pulse frequency: 4 kHz p.1 ↗
- Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
- Minimum mains voltage for frequency converters: 380 V p.1 ↗
- Protection class: IP55 p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-6 p.2 ↗ | 2BH194 | Type/size designation: side channel blower 2BH1, size 940 |
| 7-8 p.2 ↗ | -1 | Design variant / generation |
| 9-10 p.2 ↗ | BK | Motor/connection variant code |
| 11-12 p.2 ↗ | 36 / 46 | Variant suffix (36 or 46) selecting the performance/motor version |
| Z field p.2 ↗ | A11 | Ordering example substitution: 2BH1940-□□□□□-Z with Z=A11 |
| VFD type field p.2 ↗ | A–K | Frequency converter type letter (A=2FC4152-1□□□00 … K=2FC4223-1□□□00) |
Related models
Elmo Rietschle 2BH1009
Elmo Rietschle 2BH1014
Elmo Rietschle 2BH1015
Elmo Rietschle 2BH1023
Elmo Rietschle 2BH1035
Elmo Rietschle 2BH1100
Elmo Rietschle 2BH1200
Elmo Rietschle 2BH1300
Elmo Rietschle 2BH1310
Elmo Rietschle 2BH1330
Elmo Rietschle 2BH1400
Elmo Rietschle 2BH1410
Elmo Rietschle 2BH1430
Elmo Rietschle 2BH1490
Elmo Rietschle 2BH1500
Elmo Rietschle 2BH1510
Elmo Rietschle 2BH1530
Elmo Rietschle 2BH1590
Elmo Rietschle 2BH1600
Elmo Rietschle 2BH1610
Elmo Rietschle 2BH1630
Elmo Rietschle 2BH1640
Elmo Rietschle 2BH1690
Elmo Rietschle 2BH1800
Elmo Rietschle 2BH1810
Elmo Rietschle 2BH1830
Elmo Rietschle 2BH1900
Elmo Rietschle 2BH1910
Elmo Rietschle 2BH1930
Elmo Rietschle 2BH1940
Elmo Rietschle 2BH1943