Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — G-BH1 2BH1943 ATEX vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH1 943: side channel blower G-BH1 N in ATEX configuration; covers categories 3GD and 3/2D as fixed-voltage machines for 50 and 60 Hz, and category 3/2G for 50 Hz or 60 Hz versions only.

Technical Data

Parameter Value Condition
Mains frequency 50 Hz p.2 ↗ 2BH1 943
Voltage 400 D / 690 Y V p.2 ↗ 2BH1 943, 50 Hz
Current 32,0 D / 18,6 Y A p.2 ↗ 2BH1 943, 50 Hz
Power 24,8 hp p.2 ↗ 2BH1 943, 50 Hz
Max. differential pressure vacuum 68,246 inch H2O p.2 ↗ 2BH1 943, 50 Hz
Max. differential pressure pressure 68,2457 inch H2O p.2 ↗ 2BH1 943, 50 Hz
Sound level 73 dB(A) p.2 ↗ 2BH1 943, 50 Hz
Mains frequency 60 Hz p.2 ↗ 2BH1 943
Voltage 460 D V p.2 ↗ 2BH1 943, 60 Hz
Current 32,0 D A p.2 ↗ 2BH1 943, 60 Hz
Power 28,6 hp p.2 ↗ 2BH1 943, 60 Hz
Max. differential pressure vacuum 48,173 inch H2O p.2 ↗ 2BH1 943, 60 Hz
Max. differential pressure pressure 48,1734 inch H2O p.2 ↗ 2BH1 943, 60 Hz
Sound level 73 dB(A) p.2 ↗ 2BH1 943, 60 Hz

Operating Limits

  • Performance curve tolerance: ± 10 % p.1 ↗
  • Reference air temperature: 59 F p.1 ↗
  • Reference atmospheric pressure: 29.92 inch Hg p.1 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH1 Series / type designation
field 1 p.2 ↗ □ Voltage code: 1 = 230 D / 400 Y (50 Hz) or 460 Y (60 Hz); 6 = 400 D / 690 Y (50 Hz) or 460 D (60 Hz); 5 = 500 D (50 Hz) or 575 D (60 Hz)
field 2 p.2 ↗ □ Connection / ATEX variant code: D or G