Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — G-BH1 BH1014-1 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

G-BH1 side channel blower, data sheet BH1014-1 (2BH1200), single-phase motor; ordering code BH1014-1...-.□□ with voltage variants V4 (100/200 V) and V5 (115/230 V); 50 Hz and 60 Hz data.

Technical Data

Parameter Value Condition
Rated pressure -16 inch H2O p.2 ↗ BH1014-1, 50 Hz
Max. differential pressure 16 inch H2O p.2 ↗ BH1014-1, 50 Hz
Voltage 115 / 230 V p.2 ↗ BH1014-1, 50 Hz
Current 6,5 / 3,2 A p.2 ↗ BH1014-1, 50 Hz
Power 0,3 hp p.2 ↗ BH1014-1, 50 Hz
Noise level 61 dB(A) p.2 ↗ BH1014-1, 50 Hz
Weight approx. 24 lbs p.2 ↗ BH1014-1, 50 Hz
Rated pressure -22 inch H2O p.2 ↗ BH1014-1, 60 Hz
Max. differential pressure 22 inch H2O p.2 ↗ BH1014-1, 60 Hz
Voltage 115 / 230 V p.2 ↗ BH1014-1, 60 Hz
Current 5,9 / 3,0 A p.2 ↗ BH1014-1, 60 Hz
Power 0,4 hp p.2 ↗ BH1014-1, 60 Hz
Noise level 64 dB(A) p.2 ↗ BH1014-1, 60 Hz
Weight approx. 24 lbs p.2 ↗ BH1014-1, 60 Hz
Protection category IP 55 p.1 ↗ standard motors
Insulation class F p.1 ↗ standard motors

Operating Limits

  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Frequency tolerance: +/- 2 % maximum p.2 ↗
  • Single phase voltage tolerance: +/- 5 % p.2 ↗

Type Code Decoder

Position Token Meaning
1-8 p.2 ↗ BH1014-1 Type/size designation (2BH1200)
field 1 p.2 ↗ V4 Voltage variant 100/200 V, 50 Hz and 60 Hz
field 1 p.2 ↗ V5 Voltage variant 115/230 V, 50 Hz and 60 Hz