Elmo Rietschle 2BH1035
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH1035

Elmo Rietschle 2BH1035 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -160 mbar, Motor power 2.55 kW, Noise level 64 dB.

The 2BH1035 is a single-stage side-channel blower from the G-BH1 series, driven by a 2.55 kW single-phase motor (115/230 V, 50/60 Hz) and rated IP55. It delivers up to 160 mbar differential pressure in both vacuum and compressor modes at 50 Hz, and 140 mbar at 60 Hz. This model is the higher-pressure variant within the series, suited for continuous-duty air handling in pneumatic conveying, aeration, or vacuum holding applications.

Max. differential pressure
-160 mbar
Motor power
2.55 kW
Noise level
64 dB
Weight
64 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1035 Current 2.26470-14014.3–27IP55
2BH1009 ——————
2BH1014 0.325711-553.2–6.5IP55
2BH1015 1.36421-1808–16IP55
2BH1023 1.756969-19010–20IP55
2BH1100 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1300 0.2910051-1001.9IP 55
2BH1310 0.75616-2503.8 Δ / 2.20 YIP55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1400 0.956116-1805.6IP55
2BH1410 26528-3006.9IP55
2BH1430 1.164161104.2IP55
2BH1490 0.956116-1404.8 VVIP55
2BH1500 0.956521-904.2IP55
2BH1510 47148-4007.6–15.2IP55
2BH1530 1.66925-904.7IP55
2BH1590 1.36121-1902.75IP55
2BH1600 1.7572311309.9IP55
2BH1610 2.575481606IP55
2BH1630 2.56436-16017.1IP55
2BH1640 4.66565-240–26017.1IP55
2BH1690 2.56434-2009.9IP55
2BH1800 5.87713126011–22IP55
2BH1810 9.974188-46030.8IP55
2BH1830 5.875133-16019.4IP55
2BH1900 8.671183-19030.8IP55
2BH1910 12.676295-22026.4IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1940 19.973303-15063.1IP55
2BH1943 17.377330-16072.2 UU / 36.1 UIP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -160 mbar (50 Hz)
60 Hz: -140 mbar
Motor power 2.2 kW (50 Hz)
60 Hz: 2.55 kW
Noise level 64 dB (50 Hz)
Max. Differenzdruck Vakuum mfr -160 mbar (50 Hz)
Max. Differenzdruck Verdichter mfr 160 mbar (50 Hz)
Max. Differenzdruck Vakuum mfr -140 mbar (60 Hz)
Max. Differenzdruck Verdichter mfr 140 mbar (60 Hz)
Max. differential pressure compressor mfr 160 mbar (50 Hz)
Max. differential pressure vacuum mfr -140 mbar (60 Hz)
Max. differential pressure compressor mfr 140 mbar (60 Hz)
Motor phases mfr 1
Operating medium mfr Air (15 °C, 1013 mbar)
Curve tolerance mfr ±10 %
Max. differential pressure compressor (alt 50 Hz) mfr 160 mbar (50 Hz)
Max. differential pressure compressor (alt 60 Hz) mfr 140 mbar (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 64 kg (50 Hz)
60 Hz: 70 kg
Number of stages 1
Electrical, Power & Drive Specifications
Current 28.0 / 14.5 A (50 Hz)
60 Hz: 27.0 / 14.3 A
Frequency 50 Hz (50 Hz)
60 Hz: 60 Hz
Power supply 1~ 50/60 Hz
Voltage 115 / 230 V (50 Hz)
60 Hz: 115 / 230 V
Strom mfr 28.0 A (50 Hz)
Strom mfr 27.0 / 14.3 A (60 Hz)
Leistung mfr 2.55 kW (50 Hz)
Leistung mfr 2.2 kW (60 Hz)
Rated current mfr 27.0 / 14.3 A (60 Hz)
Rated power mfr 2.55 kW (60 Hz)
Voltage tolerance mfr ±5 % (1~ motor)
Frequency tolerance mfr ±2 %
Interfaces, Connections & Control
Inlet connection 15 degC
Operating Conditions, Environment & Protection
Ambient temperature limit 25 degC
Protection rating IP55
Schalldruckpegel mfr 64 dB(A) (50 Hz)
Schalldruckpegel mfr 70 dB(A) (60 Hz)
Sound pressure level mfr 64 dB(A) (50 Hz)
Sound pressure level mfr 70 dB(A) (60 Hz)

Description

Construction and series positioning

Behavior under load and media

Installation, connection, and control

Integration & Operating Notes

Electrical
Supply voltage must match motor configuration exactly

The motor is available in 115/230 V variants; applying 230 V to a 115 V configuration will permanently damage the winding. Verify the nameplate voltage and terminal link position before energizing. The 50 Hz current draw is 28.0 A at 115 V, requiring adequately sized supply conductors and branch protection.

Technical Data Sheet — G-BH1 2BH1035 compressor (EN), Electrical Data
Process Limits
Differential pressure must not exceed 160 mbar at 50 Hz

Operating above the maximum differential pressure (160 mbar at 50 Hz, 140 mbar at 60 Hz) will cause motor overload and overheating. In vacuum mode, the limit is also 160 mbar (50 Hz). Ensure system pressure relief or bypass is provided to prevent exceeding these limits during transient conditions.

Technical Data Sheet — G-BH1 2BH1035 compressor (EN), Performance Data
Mounting
Allow free air circulation around the motor

The motor is air-cooled and relies on ambient airflow for heat dissipation. Install the blower with sufficient clearance (minimum 100 mm) on all sides, especially at the fan cover, and avoid enclosing it in a sealed cabinet without forced ventilation. Ambient temperature should not exceed 40 °C unless derating is applied.

Instruction Manual, Section 3.2 Installation
Maintenance
Inspect and clean air filter and cooling passages regularly

Dust accumulation on the motor cooling fins and fan can lead to overheating. Inspect and clean every 500 operating hours or more frequently in dusty environments. The blower has sealed-for-life bearings; no lubrication is required, but bearing noise or vibration should be addressed by authorized service.

Instruction Manual, Section 6.1 Maintenance Schedule

Selection & Integration Q&A

When should I choose the 2BH1035 over the smaller 2BH1023 or 2BH1015?

Choose the 2BH1035 when your process requires up to 160 mbar differential pressure at 50 Hz from a single-phase supply. The 2BH1023 and 2BH1015 offer lower maximum pressure, so they are suitable for lower-resistance systems. The 2BH1035 also provides higher power (2.55 kW) and is physically larger (36 kg).

What are the requirements for the electrical supply and protection when integrating this blower?

The motor draws 28.0 A at 115 V, 50 Hz, so supply conductors and branch protection must be rated for at least 35 A. Use a motor starter or contactor with overload protection set to the nameplate current. For 230 V operation, current is 14.3 A at 60 Hz. Ensure the supply is capable of delivering the starting current, which can be 3–5 times the running current.

Can the 2BH1035 be installed outdoors or in a wet environment?

The IP55 rating protects against dust and water jets, making it suitable for many industrial environments, but it is not designed for outdoor installation without additional protection. Avoid direct exposure to rain, snow, or hose-directed water. The ambient temperature range is typically -20 °C to +40 °C; consult the manual for derating above 40 °C.

What maintenance items and accessories are required but not included with the base blower?

The base delivery includes the blower only. You must provide electrical cabling, a motor protection switch or contactor, and any piping or fittings for inlet and outlet. An air filter is recommended for dusty environments and is available as an accessory. Regular maintenance includes cleaning the cooling fan and checking for unusual noise or vibration; bearings are sealed and not serviceable.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — G-BH1 2BH1035 compressor (EN)
Datasheet ·195,7 КБ ·2 pp.
View PDF