Elmo Rietschle 2BH1035
Elmo Rietschle 2BH1035 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -160 mbar, Motor power 2.55 kW, Noise level 64 dB.
The 2BH1035 is a single-stage side-channel blower from the G-BH1 series, driven by a 2.55 kW single-phase motor (115/230 V, 50/60 Hz) and rated IP55. It delivers up to 160 mbar differential pressure in both vacuum and compressor modes at 50 Hz, and 140 mbar at 60 Hz. This model is the higher-pressure variant within the series, suited for continuous-duty air handling in pneumatic conveying, aeration, or vacuum holding applications.
Elmo Rietschle G-BH1 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Weight, kg | Max. differential pressure, mbar | Current, A | Protection rating |
|---|---|---|---|---|---|---|
| 2BH1035 Current | 2.2 | 64 | 70 | -140 | 14.3–27 | IP55 |
| 2BH1009 | — | — | — | — | — | — |
| 2BH1014 | 0.32 | 57 | 11 | -55 | 3.2–6.5 | IP55 |
| 2BH1015 | 1.3 | 64 | 21 | -180 | 8–16 | IP55 |
| 2BH1023 | 1.75 | 69 | 69 | -190 | 10–20 | IP55 |
| 2BH1100 | 0.2 | 53 | 10 | -120 | 1.39 Δ / 0.80 Y | IP 55 |
| 2BH1200 | 0.29 | 40 | 57 | -40 | 1.38 0.8 Y | IP55 |
| 2BH1300 | 0.29 | 100 | 51 | -100 | 1.9 | IP 55 |
| 2BH1310 | 0.7 | 56 | 16 | -250 | 3.8 Δ / 2.20 Y | IP55 |
| 2BH1330 | 0.29 | 80 | 51 | — | 1.74 Δ / 1.0 Y | IP55 |
| 2BH1400 | 0.95 | 61 | 16 | -180 | 5.6 | IP55 |
| 2BH1410 | 2 | 65 | 28 | -300 | 6.9 | IP55 |
| 2BH1430 | 1.1 | 64 | 16 | 110 | 4.2 | IP55 |
| 2BH1490 | 0.95 | 61 | 16 | -140 | 4.8 VV | IP55 |
| 2BH1500 | 0.95 | 65 | 21 | -90 | 4.2 | IP55 |
| 2BH1510 | 4 | 71 | 48 | -400 | 7.6–15.2 | IP55 |
| 2BH1530 | 1.6 | 69 | 25 | -90 | 4.7 | IP55 |
| 2BH1590 | 1.3 | 61 | 21 | -190 | 2.75 | IP55 |
| 2BH1600 | 1.75 | 72 | 31 | 130 | 9.9 | IP55 |
| 2BH1610 | 2.5 | 75 | 48 | 160 | 6 | IP55 |
| 2BH1630 | 2.5 | 64 | 36 | -160 | 17.1 | IP55 |
| 2BH1640 | 4.6 | 65 | 65 | -240–260 | 17.1 | IP55 |
| 2BH1690 | 2.5 | 64 | 34 | -200 | 9.9 | IP55 |
| 2BH1800 | 5.8 | 77 | 131 | 260 | 11–22 | IP55 |
| 2BH1810 | 9.9 | 74 | 188 | -460 | 30.8 | IP55 |
| 2BH1830 | 5.8 | 75 | 133 | -160 | 19.4 | IP55 |
| 2BH1900 | 8.6 | 71 | 183 | -190 | 30.8 | IP55 |
| 2BH1910 | 12.6 | 76 | 295 | -220 | 26.4 | IP55 |
| 2BH1930 | 8.6 | 75 | 212 | -80 | 17.6–35.2 | IP55 |
| 2BH1940 | 19.9 | 73 | 303 | -150 | 63.1 | IP55 |
| 2BH1943 | 17.3 | 77 | 330 | -160 | 72.2 UU / 36.1 U | IP55 |
Full specifications
| Max. differential pressure | -160 mbar (50 Hz) 60 Hz: -140 mbar |
| Motor power | 2.2 kW (50 Hz) 60 Hz: 2.55 kW |
| Noise level | 64 dB (50 Hz) |
| Max. Differenzdruck Vakuum mfr | -160 mbar (50 Hz) |
| Max. Differenzdruck Verdichter mfr | 160 mbar (50 Hz) |
| Max. Differenzdruck Vakuum mfr | -140 mbar (60 Hz) |
| Max. Differenzdruck Verdichter mfr | 140 mbar (60 Hz) |
| Max. differential pressure compressor mfr | 160 mbar (50 Hz) |
| Max. differential pressure vacuum mfr | -140 mbar (60 Hz) |
| Max. differential pressure compressor mfr | 140 mbar (60 Hz) |
| Motor phases mfr | 1 |
| Operating medium mfr | Air (15 °C, 1013 mbar) |
| Curve tolerance mfr | ±10 % |
| Max. differential pressure compressor (alt 50 Hz) mfr | 160 mbar (50 Hz) |
| Max. differential pressure compressor (alt 60 Hz) mfr | 140 mbar (60 Hz) |
| Weight | 64 kg (50 Hz) 60 Hz: 70 kg |
| Number of stages | 1 |
| Current | 28.0 / 14.5 A (50 Hz) 60 Hz: 27.0 / 14.3 A |
| Frequency | 50 Hz (50 Hz) 60 Hz: 60 Hz |
| Power supply | 1~ 50/60 Hz |
| Voltage | 115 / 230 V (50 Hz) 60 Hz: 115 / 230 V |
| Strom mfr | 28.0 A (50 Hz) |
| Strom mfr | 27.0 / 14.3 A (60 Hz) |
| Leistung mfr | 2.55 kW (50 Hz) |
| Leistung mfr | 2.2 kW (60 Hz) |
| Rated current mfr | 27.0 / 14.3 A (60 Hz) |
| Rated power mfr | 2.55 kW (60 Hz) |
| Voltage tolerance mfr | ±5 % (1~ motor) |
| Frequency tolerance mfr | ±2 % |
| Inlet connection | 15 degC |
| Ambient temperature limit | 25 degC |
| Protection rating | IP55 |
| Schalldruckpegel mfr | 64 dB(A) (50 Hz) |
| Schalldruckpegel mfr | 70 dB(A) (60 Hz) |
| Sound pressure level mfr | 64 dB(A) (50 Hz) |
| Sound pressure level mfr | 70 dB(A) (60 Hz) |
Description
Construction and series positioning
- Single-stage side-channel (regenerative) blower with a directly coupled single-phase AC motor; no belts or external transmission.
- Motor is rated IP55 and insulation class F, with a 36 kg total mass.
- Within the G-BH1 series, the 2BH1035 sits above the 2BH1009, 2BH1014, 2BH1015, and 2BH1023 in pressure capability, offering 160 mbar (50 Hz) versus lower pressure limits of smaller siblings. It is the choice when higher differential pressure is required from a single-phase supply.
Behavior under load and media
- At 50 Hz, maximum differential pressure is 160 mbar in both vacuum and compressor modes; at 60 Hz, the limit is 140 mbar.
- The motor draws 28.0 A at 50 Hz (115 V connection) and 27.0/14.3 A at 60 Hz (115/230 V), with power output of 2.55 kW at 50 Hz and 2.2 kW at 60 Hz.
- Sound pressure level is 64 dB(A) at 50 Hz and 70 dB(A) at 60 Hz, measured at the standard test point.
- No digitized performance curves are available; selection should rely on the datasheet pressure limits and application-specific testing.
Installation, connection, and control
- The motor is designed for single-phase 115/230 V, 50/60 Hz supply; voltage selection is via internal wiring or terminal configuration (refer to motor nameplate and manual).
- Electrical connection must be made in accordance with the wiring diagram in the instruction manual, ensuring proper grounding and protection.
- The blower is air-cooled and requires unobstructed airflow around the motor; installation should allow sufficient clearance for ventilation.
- No special control electronics are required; the blower can be switched directly via a contactor or motor starter, but account for high starting current of the single-phase motor.
- The IP55 rating permits installation in dusty or damp environments, but the blower should not be submerged or exposed to direct water jets.
Integration & Operating Notes
The motor is available in 115/230 V variants; applying 230 V to a 115 V configuration will permanently damage the winding. Verify the nameplate voltage and terminal link position before energizing. The 50 Hz current draw is 28.0 A at 115 V, requiring adequately sized supply conductors and branch protection.
Operating above the maximum differential pressure (160 mbar at 50 Hz, 140 mbar at 60 Hz) will cause motor overload and overheating. In vacuum mode, the limit is also 160 mbar (50 Hz). Ensure system pressure relief or bypass is provided to prevent exceeding these limits during transient conditions.
The motor is air-cooled and relies on ambient airflow for heat dissipation. Install the blower with sufficient clearance (minimum 100 mm) on all sides, especially at the fan cover, and avoid enclosing it in a sealed cabinet without forced ventilation. Ambient temperature should not exceed 40 °C unless derating is applied.
Dust accumulation on the motor cooling fins and fan can lead to overheating. Inspect and clean every 500 operating hours or more frequently in dusty environments. The blower has sealed-for-life bearings; no lubrication is required, but bearing noise or vibration should be addressed by authorized service.
Selection & Integration Q&A
Choose the 2BH1035 when your process requires up to 160 mbar differential pressure at 50 Hz from a single-phase supply. The 2BH1023 and 2BH1015 offer lower maximum pressure, so they are suitable for lower-resistance systems. The 2BH1035 also provides higher power (2.55 kW) and is physically larger (36 kg).
The motor draws 28.0 A at 115 V, 50 Hz, so supply conductors and branch protection must be rated for at least 35 A. Use a motor starter or contactor with overload protection set to the nameplate current. For 230 V operation, current is 14.3 A at 60 Hz. Ensure the supply is capable of delivering the starting current, which can be 3–5 times the running current.
The IP55 rating protects against dust and water jets, making it suitable for many industrial environments, but it is not designed for outdoor installation without additional protection. Avoid direct exposure to rain, snow, or hose-directed water. The ambient temperature range is typically -20 °C to +40 °C; consult the manual for derating above 40 °C.
The base delivery includes the blower only. You must provide electrical cabling, a motor protection switch or contactor, and any piping or fittings for inlet and outlet. An air filter is recommended for dusty environments and is available as an accessory. Regular maintenance includes cleaning the cooling fan and checking for unusual noise or vibration; bearings are sealed and not serviceable.