Elmo Rietschle 2BH1100
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH1100

Elmo Rietschle 2BH1100 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -90 mbar, Motor power 0.23 kW, Noise level 53 dB.

The 2BH1100 is a single-stage side-channel blower in Elmo Rietschle's G-BH1 series, available with either 3~ or 1~ motor. It delivers up to 120 mbar differential pressure in pressure mode and 110 mbar in vacuum at 50 Hz, with lower limits at 60 Hz. This modification is suited to low-flow applications requiring compact, low-power air movement.

Max. differential pressure
-90 mbar
Motor power
0.23 kW
Noise level
53 dB
Pumping speed
70 m³/h
Weight
10 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1100 Current 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1009 ——————
2BH1014 0.325711-553.2–6.5IP55
2BH1015 1.36421-1808–16IP55
2BH1023 1.756969-19010–20IP55
2BH1035 2.26470-14014.3–27IP55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1300 0.2910051-1001.9IP 55
2BH1310 0.75616-2503.8 Δ / 2.20 YIP55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1400 0.956116-1805.6IP55
2BH1410 26528-3006.9IP55
2BH1430 1.164161104.2IP55
2BH1490 0.956116-1404.8 VVIP55
2BH1500 0.956521-904.2IP55
2BH1510 47148-4007.6–15.2IP55
2BH1530 1.66925-904.7IP55
2BH1590 1.36121-1902.75IP55
2BH1600 1.7572311309.9IP55
2BH1610 2.575481606IP55
2BH1630 2.56436-16017.1IP55
2BH1640 4.66565-240–26017.1IP55
2BH1690 2.56434-2009.9IP55
2BH1800 5.87713126011–22IP55
2BH1810 9.974188-46030.8IP55
2BH1830 5.875133-16019.4IP55
2BH1900 8.671183-19030.8IP55
2BH1910 12.676295-22026.4IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1940 19.973303-15063.1IP55
2BH1943 17.377330-16072.2 UU / 36.1 UIP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -90 mbar (50 Hz)
60 Hz: -120 mbar
Motor power 0.20 kW (50 Hz)
60 Hz: 0.23 kW
Noise level 50 dB(A) (50 Hz)
60 Hz: 53 dB(A)
Pumping speed 70 m³/hour (50 Hz)
Max. differential pressure vacuum mfr -120 mbar (60 Hz)
Order No. mfr 2BH1100-7AV05
Certification mfr UL and CSA approved
Rated pressure (vacuum) mfr -90 mbar (50 Hz)
Rated pressure (vacuum) mfr -120 mbar (60 Hz)
Max. differential pressure (pressure level) mfr 100 mbar (50 Hz)
Max. differential pressure (pressure level) mfr 120 mbar (60 Hz)
Performance curve tolerance mfr ±10 %
Max. differential pressure (alt 50 Hz) mfr 100 mbar (50 Hz)
Max. differential pressure (alt 60 Hz) mfr 120 mbar (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 10 kg
Weight approx. mfr 11 kg
Electrical, Power & Drive Specifications
Current 1.39 Δ / 0.80 Y A (50 Hz)
60 Hz: 1.55 Δ / 0.90 Y A
Frequency 50 Hz (50 Hz)
60 Hz: 60 Hz
Voltage 200-240 Δ / 345-415 Y V (50 Hz)
60 Hz: 220-275 Δ / 380-480 Y V
Frequency tolerance mfr ±2 %
Voltage tolerance three-phase fixed voltage mfr ±10 %
Voltage tolerance three-phase voltage range mfr ±5 %
Voltage tolerance single phase mfr ±5 %
Operating Conditions, Environment & Protection
Protection rating IP 55
Operating temperature 25 degC
Sound pressure level mfr 50 dB(A) (50 Hz)
Sound pressure level mfr 53 dB(A) (60 Hz)

Description

Construction and series positioning

Performance behavior

Installation and operation

Integration & Operating Notes

Electrical
Verify motor variant and supply voltage before connection

The 2BH1100 is available with either a 3~ motor (220–275 V Δ / 380–480 V Y) or a 1~ motor (115/230 V). Connecting a 3~ unit to a single-phase supply, or applying the wrong voltage, will damage the motor. Confirm the model code suffix (e.g., -1AH06, -1AC03, -7AV05) against the nameplate and the technical data sheet before wiring.

Technical Data Sheet — G-BH1 2BH1100 vacuum pump (EN
Mounting
Ensure free air flow around the motor for cooling

The blower relies on ambient air for cooling. Install in a location with sufficient clearance and avoid enclosing the unit in a sealed cabinet without ventilation. Ambient temperature and altitude may further derate performance; consult the manufacturer if operating above standard conditions.

Technical Data Sheet — G-BH1 2BH1100 vacuum pump (EN

Selection & Integration Q&A

When should I choose the 2BH1100 over other G-BH1 models like the 2BH1009 or 2BH1014?

Choose the 2BH1100 when your required differential pressure is up to 120 mbar and flow demand is low, and you need a compact 10 kg unit. For higher flow or pressure, step up to siblings 2BH1009, 2BH1014, 2BH1015, or 2BH1023, which offer larger capacities.

What are the ambient temperature and duty cycle limits for the 2BH1100?

The available data sheet does not specify ambient temperature limits or duty cycle. The only temperature-related value in the data sheet is an operating temperature of 25 °C, which is not an ambient limit. Do not assume a generic 40 °C rating; confirm the permissible ambient temperature and duty cycle with Elmo Rietschle for this model. Ensure adequate ventilation to prevent overheating.

What maintenance items and accessories are required for the 2BH1100, and are they included?

The base delivery includes only the blower; no filters, silencers, or connection fittings are included. No maintenance schedule is provided in the data sheet. Request the full instruction manual for bearing inspection intervals and available accessories such as inlet filters or flexible connectors.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — G-BH1 2BH1100 vacuum pump (EN)
Datasheet ·294,4 КБ ·2 pp.
View PDF