Elmo Rietschle 2BH1300
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH1300

Elmo Rietschle 2BH1300 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -100 mbar, Motor power 0.29 kW, Noise level 100 dB.

The 2BH1300 is a side-channel (regenerative) blower in the Elmo Rietschle G-BH1 series, a single-stage, directly driven unit with a 0.40 kW motor and IP55 protection. It delivers up to 100 mbar differential pressure in vacuum or pressure at 50 Hz (120/140 mbar at 60 Hz), distinguishing it from smaller siblings by its higher pressure capability. It is intended for continuous-duty vacuum or pressure generation in industrial processes requiring oil-free, contact-free gas handling.

Max. differential pressure
-100 mbar
Motor power
0.29 kW
Noise level
100 dB
Weight
51 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1300 Current 0.2910051-1001.9IP 55
2BH1009 ——————
2BH1014 0.325711-553.2–6.5IP55
2BH1015 1.36421-1808–16IP55
2BH1023 1.756969-19010–20IP55
2BH1035 2.26470-14014.3–27IP55
2BH1100 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1310 0.75616-2503.8 Δ / 2.20 YIP55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1400 0.956116-1805.6IP55
2BH1410 26528-3006.9IP55
2BH1430 1.164161104.2IP55
2BH1490 0.956116-1404.8 VVIP55
2BH1500 0.956521-904.2IP55
2BH1510 47148-4007.6–15.2IP55
2BH1530 1.66925-904.7IP55
2BH1590 1.36121-1902.75IP55
2BH1600 1.7572311309.9IP55
2BH1610 2.575481606IP55
2BH1630 2.56436-16017.1IP55
2BH1640 4.66565-240–26017.1IP55
2BH1690 2.56434-2009.9IP55
2BH1800 5.87713126011–22IP55
2BH1810 9.974188-46030.8IP55
2BH1830 5.875133-16019.4IP55
2BH1900 8.671183-19030.8IP55
2BH1910 12.676295-22026.4IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1940 19.973303-15063.1IP55
2BH1943 17.377330-16072.2 UU / 36.1 UIP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -100 mbar (50 Hz)
60 Hz: -100 mbar
Motor power 1.1 Y kW (50 Hz)
60 Hz: 0.29 kW
Noise level 100 dB (50 Hz)
60 Hz: 100 dB
Max. differential pressure vacuum mfr 130 mbar (50 Hz)
Max. differential pressure vacuum mfr 160 mbar (60 Hz)
Rated pressure vacuum mfr -120 mbar (50 Hz)
Rated pressure vacuum mfr -150 mbar (60 Hz)
Rated pressure compressor mfr 100 mbar (50 Hz)
Rated pressure compressor mfr 100 mbar (60 Hz)
Max. differential pressure compressor mfr 130 mbar (50 Hz)
Max. differential pressure compressor mfr 160 mbar (60 Hz)
Max. differential pressure vacuum (alt 50 Hz) mfr -120 mbar (50 Hz)
Max. differential pressure vacuum (alt 60 Hz) mfr -150 mbar (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 51 kg (50 Hz)
60 Hz: 55 kg
Weight approx. mfr 11 kg
Weight approx. (alt 50 Hz) mfr 58 kg (50 Hz)
Weight approx. (alt 60 Hz) mfr 60 kg (60 Hz)
Electrical, Power & Drive Specifications
Current 1.9 A (50 Hz)
60 Hz: 1.74 / 1.0 Y A
Frequency 50 Hz (50 Hz)
60 Hz: 60 Hz
Voltage 200-240 V (50 Hz)
60 Hz: 220-275 / 380-480 Y V
Rated voltage mfr 220-275 / 380-480 V (60 Hz)
Rated current mfr 2.4 / 1.4 A (50 Hz)
Rated current mfr 2.4 A (60 Hz)
Current (alt 50 Hz) mfr 2.4 / 1.4 Y A (50 Hz)
Power (alt 50 Hz) mfr 0.40 kW (50 Hz)
Current (alt 60 Hz) mfr 2.4 / 1.4 Y A (60 Hz)
Power (alt 60 Hz) mfr 0.50 kW (60 Hz)
Operating Conditions, Environment & Protection
Protection rating IP 55
Cooling type F
Sound pressure level mfr 60 dB(A)
Sound pressure level mfr 58 dB(A) (50 Hz)
Sound pressure level mfr 60 dB(A) (60 Hz)
Sound pressure level (alt 50 Hz) mfr 130 dB (50 Hz)
Sound pressure level (alt 60 Hz) mfr 160 dB (60 Hz)

Description

Construction and series positioning

Behavior under load and media

Installation, connection and control

Integration & Operating Notes

Electrical
Verify supply voltage matches motor variant before connection

The 2BH1300 is offered with different motor windings for 50 Hz and 60 Hz operation, with voltage ranges of 200–240 V, 220–275 V or 380–480 V. Connecting a motor to a voltage outside its rated range will cause overheating or failure. Check the nameplate and terminal box diagram to confirm the correct supply.

Technical Data Sheet — G-BH1 2BH1300 vacuum pump (EN
Process Limits
Do not exceed maximum differential pressure of 100 mbar at 50 Hz

Operating above the specified maximum differential pressure (100 mbar at 50 Hz, 120 mbar vacuum / 140 mbar pressure at 60 Hz) will overload the motor and may cause overheating or mechanical damage. Use a pressure relief valve or control the process to stay within these limits.

Technical Data Sheet — G-BH1 2BH1300 vacuum pump (EN
Mounting
Ensure unobstructed cooling air flow around the motor

The motor is IP55 protected but relies on convection cooling. Mount the blower so that the cooling air intake and outlet are not blocked, and avoid enclosing the unit in a small, unventilated space. Minimum clearance around the motor is typically required as per general installation guidelines.

Technical Data Sheet — G-BH1 2BH1300 vacuum pump (EN
Maintenance
Inspect and clean the impeller and silencer periodically

Dust or debris accumulation in the side channel or silencer reduces performance and can cause imbalance. The maintenance interval depends on the process dust load; inspect at least every 2000 operating hours or more frequently in dirty environments. Clean with compressed air or a soft brush; do not use solvents on the impeller.

Technical Data Sheet — G-BH1 2BH1300 vacuum pump (EN

Selection & Integration Q&A

When should I choose the 2BH1300 instead of a smaller sibling like the 2BH1023?

Choose the 2BH1300 when your process requires up to 100 mbar differential pressure at 50 Hz (120/140 mbar at 60 Hz). The smaller siblings (2BH1009, 2BH1014, 2BH1015, 2BH1023) offer lower maximum pressure. If your required pressure is below their limits, they may be more energy-efficient; select the 2BH1300 for higher pressure demands.

What are the power supply and control requirements for the 2BH1300?

The motor is available in 200–240 V (50 Hz), 220–275 V (60 Hz) or 380–480 V (60 Hz) variants, with rated current 2.4 A or 1.4 A. It requires a suitable motor starter or contactor with overload protection set to the rated current. No VFD is required for basic operation, but if used, ensure the drive is rated for the motor power and provides a clean sine wave output.

What maintenance is required and what consumables are not included?

Periodic inspection and cleaning of the impeller and silencer are required; no lubrication is needed. Base delivery does not include suction/discharge silencers, filters, or flexible connectors, which must be ordered separately. Spare parts such as gaskets and bearings are available from the manufacturer. Refer to the manual for detailed maintenance intervals.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — G-BH1 2BH1300 vacuum pump (EN)
Datasheet ·235,5 КБ ·2 pp.
View PDF