Elmo Rietschle 2BH1400
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH1400

Elmo Rietschle 2BH1400 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -180 mbar, Motor power 1.1 kW, Noise level 64 dB.

The 2BH1400 is a side-channel blower with an IE3 three-phase motor, available in voltage variants for 50/60 Hz operation, delivering up to 170 mbar differential pressure in pressure mode and -180 mbar in vacuum mode. It is distinguished from smaller siblings (2BH1009–2BH1023) by its higher power rating and larger pressure/vacuum capability, making it suitable for medium-duty pneumatic conveying, aeration, or vacuum lifting in industrial systems.

Max. differential pressure
-180 mbar
Motor power
1.1 kW
Noise level
64 dB
Weight
16 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1400 Current 0.956116-1805.6IP55
2BH1009 ——————
2BH1014 0.325711-553.2–6.5IP55
2BH1015 1.36421-1808–16IP55
2BH1023 1.756969-19010–20IP55
2BH1035 2.26470-14014.3–27IP55
2BH1100 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1300 0.2910051-1001.9IP 55
2BH1310 0.75616-2503.8 Δ / 2.20 YIP55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1410 26528-3006.9IP55
2BH1430 1.164161104.2IP55
2BH1490 0.956116-1404.8 VVIP55
2BH1500 0.956521-904.2IP55
2BH1510 47148-4007.6–15.2IP55
2BH1530 1.66925-904.7IP55
2BH1590 1.36121-1902.75IP55
2BH1600 1.7572311309.9IP55
2BH1610 2.575481606IP55
2BH1630 2.56436-16017.1IP55
2BH1640 4.66565-240–26017.1IP55
2BH1690 2.56434-2009.9IP55
2BH1800 5.87713126011–22IP55
2BH1810 9.974188-46030.8IP55
2BH1830 5.875133-16019.4IP55
2BH1900 8.671183-19030.8IP55
2BH1910 12.676295-22026.4IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1940 19.973303-15063.1IP55
2BH1943 17.377330-16072.2 UU / 36.1 UIP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -180 mbar (50 Hz)
60 Hz: -170 mbar
Motor power 0.95 kW (50 Hz)
60 Hz: 1.10 kW
Noise level 61 dB (50 Hz)
60 Hz: 64 dB
Max. differential pressure vacuum mfr -170 mbar (60 Hz)
Order No. mfr 2BH1400-0AK11
Max. differential pressure (pressure) (alt 50 Hz) mfr 170 mbar (50 Hz)
Max. differential pressure (pressure) (alt 60 Hz) mfr 160 mbar (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 16 kg
Number of stages 1
Electrical, Power & Drive Specifications
Current 5.6 A (50 Hz)
60 Hz: 4.8 A
Frequency 50/60 Hz
Voltage 190-210 V (50 Hz)
60 Hz: 190-210 / 380-420 V
Rated current mfr 4.8 Δ A (50 Hz)
Rated current mfr 4.8 YY A (60 Hz)
Efficiency class mfr IE3
Rated voltage mfr 200 YY V (60 Hz)
Efficiency class mfr IE3 (50 Hz)
Efficiency class mfr NP (60 Hz)
Frequency tolerance mfr ±2 %
Voltage tolerance three-phase motors mfr ±10 %
Operating Conditions, Environment & Protection
Protection rating IP55
Sound pressure level mfr 61 dB(A) (50 Hz)
Sound pressure level mfr 64 dB(A) (60 Hz)

Description

Construction and series positioning

The 2BH1400 is a regenerative ring blower in the G-BH1 series, equipped with an IE3 efficiency-class motor and IP55 protection. It is the largest model among the listed siblings (2BH1009, 2BH1014, 2BH1015, 2BH1023), offering higher differential pressure and flow capacity. The motor is designed for dual voltage/frequency operation: 220–240 V Δ / 380–420 V Y at 50 Hz and 440–480 V Y at 60 Hz, with rated currents of 3.7 A Δ / 2.1 A Y (50 Hz) and 2.1 A Y (60 Hz). Power output is 0.95 kW at 50 Hz and 1.10 kW at 60 Hz. The blower weighs approximately 16 kg and has insulation class F.

Performance characteristics

Maximum differential pressure is 170 mbar in pressure mode and -180 mbar in vacuum mode at 50 Hz; at 60 Hz these values are slightly lower (160 mbar and -170 mbar). Sound pressure level is 61 dB(A) at 50 Hz and 64 dB(A) at 60 Hz. No digitized curve points are available, so the exact flow-pressure relationship must be obtained from the manufacturer’s performance curves. The side-channel design provides oil-free operation and is suitable for continuous duty, but the absence of curve data means that system designers should verify operating points with Elmo Rietschle’s selection software or technical support.

Installation and operation

The blower is typically mounted on a rigid base with vibration isolators. Electrical connection requires a suitable motor protection switch and fusing according to the rated current. The IP55 rating allows outdoor installation but the motor should be protected from direct water jets. The IE3 motor is designed for direct-on-line starting; for soft starting or speed control, a variable frequency drive (VFD) may be used, but the motor insulation and bearing currents must be considered. The data sheet mentions UL and CSA certifications for the series, indicating compliance with North American standards. No specific control or I/O details are provided in the digest, so refer to the full manual for terminal box connections and wiring diagrams.

Integration & Operating Notes

Process Limits
Do not exceed 170 mbar pressure or -180 mbar vacuum at 50 Hz

The maximum differential pressure is 170 mbar in pressure mode and -180 mbar in vacuum mode at 50 Hz. At 60 Hz, the limits are 160 mbar and -170 mbar respectively. Exceeding these limits can cause overheating, motor overload, or mechanical damage. Install pressure/vacuum relief valves or monitor the process to ensure these limits are not exceeded during operation.

Technical Data Sheet — 2BH1400 IE3 vacuum pump (EN

Selection & Integration Q&A

When should I choose the 2BH1400 over the smaller 2BH1023 or larger siblings?

Choose the 2BH1400 when your required differential pressure is up to 170 mbar (pressure) or -180 mbar (vacuum) at 50 Hz, and flow demand exceeds the capacity of the 2BH1023. The 2BH1400 offers higher power (0.95 kW) than smaller models, making it suitable for medium-duty applications. For higher pressures or flows, consider larger models in the G-BH1 series not listed here.

What are the requirements for the power supply and motor protection when using a VFD?

The motor is IE3 efficiency class and can be operated with a VFD, but the VFD must be rated for the motor current (3.7 A at 50 Hz delta). Use a VFD with adjustable switching frequency and consider a dv/dt filter to protect the motor insulation. Ensure the VFD is set to the correct motor parameters (voltage, frequency, current) and that the motor is either inverter-duty rated or the VFD output is filtered. Consult Elmo Rietschle for approved VFD operation.

What are the ambient temperature limits and installation considerations for outdoor use?

The standard ambient temperature limit is 40°C. For outdoor installation, the IP55 rating protects against dust and water jets, but the motor should be shielded from direct sunlight and rain. Ensure the installation location provides adequate ventilation and does not exceed the ambient temperature limit. If the blower is installed in an enclosure, provide forced ventilation to maintain temperature within limits.

What maintenance items and accessories are required for commissioning and long-term operation?

The base delivery includes the blower only. For commissioning, you will need a motor protection switch, power cables, and possibly a VFD. For maintenance, spare inlet filters and possibly a replacement impeller may be needed depending on the process. Regularly check the motor bearings and clean the impeller. Refer to the manual for a detailed maintenance schedule and spare parts list.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH1400 IE3 vacuum pump (EN)
Datasheet ·307,6 КБ ·2 pp.
View PDF