Elmo Rietschle 2BH1530
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH1530

Elmo Rietschle 2BH1530 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -90 mbar, Motor power 1.3 kW, Noise level 60 dB.

The 2BH1530 is a side-channel blower from the G-BH1 series, driven by an IE3 efficiency-class motor and configured for 380–420 V Δ / 660–725 Y at 50 Hz or 460 V Δ at 60 Hz. It delivers 250 m³/h suction capacity at -220 mbar (50 Hz) and -260 mbar (60 Hz), with a maximum differential pressure of 250 mbar in pressure mode. This modification is the higher-capacity unit within the 2BH10xx sibling group, intended for continuous vacuum or pressure duty in industrial processes requiring oil-free, contactless gas handling.

Max. differential pressure
-90 mbar
Motor power
1.3 kW
Noise level
60 dB
Weight
25 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1530 Current 1.66925-904.7IP55
2BH1009 ——————
2BH1014 0.325711-553.2–6.5IP55
2BH1015 1.36421-1808–16IP55
2BH1023 1.756969-19010–20IP55
2BH1035 2.26470-14014.3–27IP55
2BH1100 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1300 0.2910051-1001.9IP 55
2BH1310 0.75616-2503.8 Δ / 2.20 YIP55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1400 0.956116-1805.6IP55
2BH1410 26528-3006.9IP55
2BH1430 1.164161104.2IP55
2BH1490 0.956116-1404.8 VVIP55
2BH1500 0.956521-904.2IP55
2BH1510 47148-4007.6–15.2IP55
2BH1590 1.36121-1902.75IP55
2BH1600 1.7572311309.9IP55
2BH1610 2.575481606IP55
2BH1630 2.56436-16017.1IP55
2BH1640 4.66565-240–26017.1IP55
2BH1690 2.56434-2009.9IP55
2BH1800 5.87713126011–22IP55
2BH1810 9.974188-46030.8IP55
2BH1830 5.875133-16019.4IP55
2BH1900 8.671183-19030.8IP55
2BH1910 12.676295-22026.4IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1940 19.973303-15063.1IP55
2BH1943 17.377330-16072.2 UU / 36.1 UIP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -120 mbar (50 Hz)
60 Hz: -90 mbar
Motor power 1.30 kW (50 Hz)
60 Hz: 1.60 kW
Noise level 60 dB (50 Hz)
60 Hz: 69 dB
Suction capacity mfr 250 m3/h (50 Hz, vacuum -220 mbar)
Suction capacity mfr 250 m3/h (60 Hz, vacuum -260 mbar)
Vacuum mfr -120 mbar (50 Hz)
Order No. mfr 2BH1530-0AK11 (50 Hz)
Vacuum mfr -90 mbar (60 Hz)
Order No. mfr 2BH1530-0AK11 (60 Hz)
Vacuum mfr -90 mbar (60 Hz NP)
Max. differential pressure (vacuum) (alt 50 Hz) mfr -220 mbar (50 Hz)
Max. differential pressure (vacuum) (alt 60 Hz) mfr -260 mbar (60 Hz)
Max. differential pressure (pressure) (alt 50 Hz) mfr 250 mbar (50 Hz)
Max. differential pressure (pressure) (alt 60 Hz) mfr 250 mbar (60 Hz)
Stages (alt var) mfr 3
Dimensions, Weight & Mechanical Design
Weight 25 kg
Number of stages 1
Weight approx. mfr 31 kg
Weight approx. (alt var) mfr 31 kg
Electrical, Power & Drive Specifications
Current 4.7 A (50 Hz)
60 Hz: 6.3 / 3.2 A
Frequency 50/60 Hz
Power supply 3~ 50/60 Hz
Voltage 190-210 V (50 Hz)
60 Hz: 190-210 / 380-420 V
Power consumption at pump shaft mfr 2.50 kW (50 Hz, -220 mbar)
Power consumption at pump shaft mfr 3.00 kW (60 Hz, -260 mbar)
Efficiency class mfr IE3
Efficiency class mfr IE3 (50 Hz)
Efficiency class mfr IE3 (60 Hz)
Efficiency class mfr NP (60 Hz NP)
Power (alt 50 Hz) mfr 2.50 kW (50 Hz)
Voltage (alt 50 Hz) mfr 380-420 / 660-725 V (50 Hz)
Voltage (alt 60 Hz) mfr 440-480 V (60 Hz)
Current (alt 50 Hz) mfr 8.8 / 5.1 A (50 Hz)
Current (alt 60 Hz) mfr 5.2 A (60 Hz)
Operating Conditions, Environment & Protection
Protection rating IP55
Sound pressure level mfr 60 dB(A) (50 Hz)
Sound pressure level mfr 69 dB(A) (60 Hz)
Sound pressure level mfr 69 dB(A) (60 Hz NP)
Sound pressure level (alt 50 Hz) mfr 69 dB (50 Hz)
Sound pressure level (alt 60 Hz) mfr 70 dB (60 Hz)

Description

Construction and series positioning

Behavior under load and media

Installation and operation

Integration & Operating Notes

Process Limits
Do not exceed -260 mbar vacuum or 250 mbar pressure differential

The maximum vacuum level is -260 mbar at 60 Hz; the maximum pressure-mode differential is 250 mbar at 60 Hz. Operating beyond these limits increases shaft power above the 3.00 kW rating and can overheat the motor or overload the impeller. Install a relief valve or pressure switch to keep the process within the envelope.

Technical Data Sheet — 2BH1530 IE3 vacuum pump (EN)
Control & I/O
Set overload protection to the motor nameplate current for the actual connection

The motor draws 5.0 A Δ / 2.9 A Y at 50 Hz and 5.2 A Δ at 60 Hz. A thermal overload relay or drive overload parameter must be set to the motor nameplate full-load current for the actual connection (delta or star) so that a blocked filter, closed valve, or impeller fouling trips the unit before the winding exceeds class F temperature limits.

Technical Data Sheet — 2BH1530 IE3 vacuum pump (EN)
Maintenance
Inspect inlet filter and impeller clearance at regular intervals

Because the side-channel impeller runs contactless, wear is minimal, but dust ingress through the IP55 motor is not the only concern: the process gas path must be kept free of particles that can erode the impeller. Schedule periodic inspection of any inlet filter and check for unusual noise or current rise, which indicate fouling or bearing wear.

Technical Data Sheet — 2BH1530 IE3 vacuum pump (EN)

Selection & Integration Q&A

When should I choose the 2BH1530 instead of the smaller 2BH1009 or 2BH1023 siblings?

Pick the 2BH1530 when your process needs around 250 m³/h at -220 to -260 mbar and up to 2.5–3.0 kW shaft power. The 2BH10xx siblings are smaller-frame units; choose them only if your required flow and differential pressure fall within their lower capacity, avoiding unnecessary energy use.

What starter or drive and supply configuration does the 2BH1530-0AQ37 require?

Use a starter or VFD rated for the motor nameplate power and current (e.g., 5.0 A Δ / 2.9 A Y at 50 Hz, 5.2 A Δ at 60 Hz), set to the motor's nameplate current. Connect the 2BH1530-0AQ37 winding in delta for 380–420 V at 50 Hz or 460 V at 60 Hz, or in star for 660–725 V at 50 Hz. Confirm the order code matches your site voltage before wiring.

What maintenance items and accessories are not included with the base 2BH1530 delivery?

The base delivery is the blower only; inlet filters, silencers, flexible connectors, relief valves, and a starter or VFD are not included and must be specified separately. No spare parts kit is listed in the verified data. Plan periodic inspection of the process gas path and motor bearings, and verify the order code for voltage variant before commissioning.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH1530 IE3 vacuum pump (EN)
Datasheet ·312,3 КБ ·2 pp.
View PDF