The 2BH1800 is a side-channel blower from the Elmo Rietschle G-BH1 series, configured with a 3~ IE3 motor for 50/60 Hz operation. It delivers up to 280 mbar vacuum and 260 mbar pressure at 50 Hz, positioning it as the highest-capacity model among siblings 2BH1009, 2BH1014, 2BH1015, and 2BH1023. It is intended for continuous-duty vacuum or pressure generation in industrial processes requiring oil-free, contactless compression.
Elmo Rietschle G-BH1 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Weight, kg | Max. differential pressure, mbar | Current, A | Protection rating |
|---|---|---|---|---|---|---|
| 2BH1800 Current | 5.8 | 77 | 131 | 260 | 11–22 | IP55 |
| 2BH1009 | — | — | — | — | — | — |
| 2BH1014 | 0.32 | 57 | 11 | -55 | 3.2–6.5 | IP55 |
| 2BH1015 | 1.3 | 64 | 21 | -180 | 8–16 | IP55 |
| 2BH1023 | 1.75 | 69 | 69 | -190 | 10–20 | IP55 |
| 2BH1035 | 2.2 | 64 | 70 | -140 | 14.3–27 | IP55 |
| 2BH1100 | 0.2 | 53 | 10 | -120 | 1.39 Δ / 0.80 Y | IP 55 |
| 2BH1200 | 0.29 | 40 | 57 | -40 | 1.38 0.8 Y | IP55 |
| 2BH1300 | 0.29 | 100 | 51 | -100 | 1.9 | IP 55 |
| 2BH1310 | 0.7 | 56 | 16 | -250 | 3.8 Δ / 2.20 Y | IP55 |
| 2BH1330 | 0.29 | 80 | 51 | — | 1.74 Δ / 1.0 Y | IP55 |
| 2BH1400 | 0.95 | 61 | 16 | -180 | 5.6 | IP55 |
| 2BH1410 | 2 | 65 | 28 | -300 | 6.9 | IP55 |
| 2BH1430 | 1.1 | 64 | 16 | 110 | 4.2 | IP55 |
| 2BH1490 | 0.95 | 61 | 16 | -140 | 4.8 VV | IP55 |
| 2BH1500 | 0.95 | 65 | 21 | -90 | 4.2 | IP55 |
| 2BH1510 | 4 | 71 | 48 | -400 | 7.6–15.2 | IP55 |
| 2BH1530 | 1.6 | 69 | 25 | -90 | 4.7 | IP55 |
| 2BH1590 | 1.3 | 61 | 21 | -190 | 2.75 | IP55 |
| 2BH1600 | 1.75 | 72 | 31 | 130 | 9.9 | IP55 |
| 2BH1610 | 2.5 | 75 | 48 | 160 | 6 | IP55 |
| 2BH1630 | 2.5 | 64 | 36 | -160 | 17.1 | IP55 |
| 2BH1640 | 4.6 | 65 | 65 | -240–260 | 17.1 | IP55 |
| 2BH1690 | 2.5 | 64 | 34 | -200 | 9.9 | IP55 |
| 2BH1810 | 9.9 | 74 | 188 | -460 | 30.8 | IP55 |
| 2BH1830 | 5.8 | 75 | 133 | -160 | 19.4 | IP55 |
| 2BH1900 | 8.6 | 71 | 183 | -190 | 30.8 | IP55 |
| 2BH1910 | 12.6 | 76 | 295 | -220 | 26.4 | IP55 |
| 2BH1930 | 8.6 | 75 | 212 | -80 | 17.6–35.2 | IP55 |
| 2BH1940 | 19.9 | 73 | 303 | -150 | 63.1 | IP55 |
| 2BH1943 | 17.3 | 77 | 330 | -160 | 72.2 UU / 36.1 U | IP55 |
Full specifications
| Max. differential pressure | 260 mbar (50 Hz, 2BH1800-2AK11) 60 Hz, 2BH1800-2AK11: 230 mbar |
| Motor power | 5.1 kW (50 Hz, 2BH1800-2AK11) 60 Hz, 2BH1800-2AK11: 5.8 kW |
| Noise level | 75 dB(A) (50 Hz, 2BH1800-2AK11) 60 Hz, 2BH1800-2AK11: 77 dB(A) |
| Max. differential pressure vacuum mfr | -280 mbar (50 Hz) |
| Max. differential pressure vacuum mfr | -250 mbar (60 Hz) |
| Motor type mfr | 3~ |
| Series mfr | G-BH 1 N HT |
| Model mfr | 2BH1800-2 |
| Product type mfr | Side channel blower with IE3-motors |
| Operation mfr | Vacuum pump / compressor, continuous operation o |
| Approvals mfr | UL and CSA approved (UL 1450 and CAN/CSA C22.2 N |
| Performance curves basis mfr | Air at 15 °C, atmospheric pressure 1013 mbar, to |
| Total pressure difference validity mfr | Suction and ambient temperature up to 25 °C |
| Weight | 131 kg (2BH1800-2AK11) |
| Current | 19.4 A (50 Hz, 2BH1800-2AK11) 60 Hz, 2BH1800-2AK11: 22.0 / 11.0 A |
| Frequency | 50 Hz (2BH1800-2AK11) |
| Power supply | 3~ 50/60 Hz |
| Voltage | 190-210 V (50 Hz, 2BH1800-2AK11) 60 Hz, 2BH1800-2AK11: 190-210 / 380-480 V |
| Efficiency class mfr | IE3 (50 Hz) |
| Efficiency class mfr | IE3 (60 Hz) |
| Frequency (alt 2BH1800-2AK11) mfr | 60 Hz (2BH1800-2AK11) |
| Protection rating | IP55 |
| Operating temperature | 25 degC (maximum for stated total pressure differences) |
| Sound pressure level mfr | 75 dB(A) (50 Hz) |
| Sound pressure level mfr | 77 dB(A) (60 Hz) |
Description
Construction and Series Positioning
The 2BH1800 is a regenerative (side-channel) blower with a dynamically balanced impeller running without contact, ensuring oil-free operation. Within the G-BH1 series, it is the largest model, offering the highest differential pressures and motor power. The IE3 motor and IP55 protection make it suitable for demanding environments. The 3~ motor is designed for 50/60 Hz dual-frequency operation, with voltage ranges 190–210 V at 50 Hz and 200 V at 60 Hz.
Performance Characteristics
At 50 Hz, the blower achieves a maximum vacuum of -280 mbar and pressure of 260 mbar; at 60 Hz, these values are -250 mbar and 230 mbar, respectively. The motor delivers 5.1 kW at 50 Hz and 5.8 kW at 60 Hz, with currents of 22.0 A and 19.4 A. Sound pressure level is 75 dB(A) at 50 Hz and 77 dB(A) at 60 Hz. The unit weighs approximately 131 kg. No digitized curve points are available, so precise flow rates must be derived from the technical data sheet or manufacturer's performance curves.
Installation and Operation
Installation requires a flat, vibration-isolated mounting surface. The IP55 protection allows operation in dusty and humid environments but does not permit immersion. The motor must be connected to a suitable 3-phase supply with overload protection. The insulation class F provides thermal margin. The blower can be used for both vacuum and pressure applications, but the direction of rotation must be correct for the desired function. The technical data sheet indicates compliance with UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate E225239).
Integration & Operating Notes
Exceeding the voltage range can overheat the motor or cause insulation failure. The 2BH1800 is designed for dual-frequency operation, but the supply must be within the specified limits. Use a voltage stabilizer if the mains fluctuate beyond ±5%.
Dust buildup on the impeller can cause imbalance, vibration, and reduced efficiency. Inspect and clean at intervals determined by the process dust load. Use compressed air or a soft brush; do not use solvents that may damage the impeller. Check motor bearings for noise or play and replace as needed.
Selection & Integration Q&A
Choose the 2BH1800 when your process requires vacuum up to -280 mbar or pressure up to 260 mbar at 50 Hz, and flow rates that the smaller models cannot achieve. The 2BH1009 and 2BH1023 offer lower maximum pressures and motor power, so they are suitable for lower-demand applications. The 2BH1800 is the highest-capacity model in the series, but its larger size and 131 kg weight may require more robust mounting.
The 2BH1800 requires a 3-phase supply of 190–210 V at 50 Hz or 200 V at 60 Hz. It draws 22.0 A at 50 Hz and 19.4 A at 60 Hz. Use a motor protection circuit breaker or fuses rated for the current, and ensure the supply can handle the starting current. The motor is IE3 efficiency and IP55 protected, but the installation must include proper earthing and overload protection.
Mount the blower on a flat, rigid surface that can support its 131 kg weight and absorb vibration. The IP55 rating allows operation in dusty and wet environments, but avoid direct water jets and ensure adequate ventilation. Ambient temperature limits are not specified in the provided facts; refer to the manual. The blower can operate continuously, but ensure the motor current does not exceed the rated values.
The 2BH1800 uses contactless operation, so no internal lubrication is needed. However, regularly inspect and clean the impeller and housing to prevent dust buildup. Check motor bearings periodically and replace if noisy. The base delivery does not include power cables, motor protection devices, or mounting feet; these must be ordered separately. Refer to the manual for specific service intervals.