Elmo Rietschle 2BH1810
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH1810

Elmo Rietschle 2BH1810 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -460 mbar, Motor power 9.9 kW, Noise level 78 dB.

The 2BH1810 is a side-channel blower from the Elmo Rietschle G-BH1 series, featuring a three-phase IE3 motor and a single-stage regenerative impeller. It delivers up to 460 mbar vacuum and 420 mbar pressure at 60 Hz, distinguishing it from smaller siblings like the 2BH1009 by its higher power and flow capacity. It is used for contactless conveying, vacuum lifting, and aeration in industrial systems where oil-free, pulsation-free air is required.

Max. differential pressure
-460 mbar
Motor power
9.9 kW
Noise level
78 dB
Weight
188 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1810 Current 9.974188-46030.8IP55
2BH1009 ——————
2BH1014 0.325711-553.2–6.5IP55
2BH1015 1.36421-1808–16IP55
2BH1023 1.756969-19010–20IP55
2BH1035 2.26470-14014.3–27IP55
2BH1100 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1300 0.2910051-1001.9IP 55
2BH1310 0.75616-2503.8 Δ / 2.20 YIP55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1400 0.956116-1805.6IP55
2BH1410 26528-3006.9IP55
2BH1430 1.164161104.2IP55
2BH1490 0.956116-1404.8 VVIP55
2BH1500 0.956521-904.2IP55
2BH1510 47148-4007.6–15.2IP55
2BH1530 1.66925-904.7IP55
2BH1590 1.36121-1902.75IP55
2BH1600 1.7572311309.9IP55
2BH1610 2.575481606IP55
2BH1630 2.56436-16017.1IP55
2BH1640 4.66565-240–26017.1IP55
2BH1690 2.56434-2009.9IP55
2BH1800 5.87713126011–22IP55
2BH1830 5.875133-16019.4IP55
2BH1900 8.671183-19030.8IP55
2BH1910 12.676295-22026.4IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1940 19.973303-15063.1IP55
2BH1943 17.377330-16072.2 UU / 36.1 UIP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -460 mbar (50 Hz)
60 Hz: -420 mbar
Motor power 8.6 kW (50 Hz)
60 Hz: 9.9 kW
Noise level 74 dB (50 Hz)
60 Hz: 78 dB
Max. differential pressure vacuum mfr -420 mbar (60 Hz)
Approval mfr UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate
Order No. mfr 2BH1810-1HK26
Certification mfr UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate
Max. differential pressure (pressure) (alt 50 Hz) mfr 420 mbar (50 Hz)
Max. differential pressure (pressure) (alt 60 Hz) mfr 350 mbar (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 188 kg
Electrical, Power & Drive Specifications
Current 30.8 A (50 Hz)
60 Hz: 35.2 A
Power supply 3~ 50/60 Hz
Voltage 190-210 V (50 Hz)
60 Hz: 200 V
Efficiency class mfr IE3 (50 Hz)
Efficiency class mfr NP (60 Hz)
Frequency mfr 50/60 Hz
Voltage tolerance mfr ±10 %
Frequency tolerance mfr ±2 %
Operating Conditions, Environment & Protection
Protection rating IP55
Sound pressure level mfr 74 dB(A) (50 Hz)
Sound pressure level mfr 78 dB(A) (60 Hz)

Description

Construction and series positioning

Performance and behavior

Installation and operation

Integration & Operating Notes

Electrical
Supply must handle starting current

The motor draws 30.8 A at 50 Hz and 31.4 A at 60 Hz during normal operation, but starting current can be several times higher. Ensure the upstream protection and contactors are rated for the locked-rotor current to avoid nuisance tripping or voltage dips.

Technical Data Sheet — 2BH1810 IE3 vacuum pump (EN), Electrical Data
Mounting
Install on a flat, vibration-damped base

The blower weighs approximately 188 kg and generates vibration during operation. Mount it on a rigid, level surface using anti-vibration mounts to prevent transmission of vibration to piping and structures, and to avoid misalignment.

Technical Data Sheet — 2BH1810 IE3 vacuum pump (EN), Mechanical Data
Process Limits
Do not exceed 460 mbar vacuum or 420 mbar pressure

Operating beyond the maximum differential pressure can cause overheating and motor overload. The limits are -460 mbar in vacuum and +420 mbar in pressure at 50 Hz; at 60 Hz, the limits are -420 mbar and +350 mbar. Use relief valves or control devices to stay within these limits.

Technical Data Sheet — 2BH1810 IE3 vacuum pump (EN), Performance Data
Environment
IP55 motor allows dusty and wet environments

The IP55 protection category permits operation in areas with airborne dust and water spray. However, ensure adequate ventilation and avoid direct exposure to rain or washdown to prevent condensation inside the motor.

Technical Data Sheet — 2BH1810 IE3 vacuum pump (EN), Motor Data
Maintenance
Regularly inspect and clean the impeller and filter

Accumulation of dust or debris on the impeller can cause imbalance and reduce performance. Inspect and clean the impeller and inlet filter at intervals determined by the process dust load, or at least every 2000 operating hours. Replace the filter element when pressure drop increases.

Technical Data Sheet — 2BH1810 IE3 vacuum pump (EN), Maintenance

Selection & Integration Q&A

When should I choose the 2BH1810 over smaller siblings like the 2BH1023?

Choose the 2BH1810 when you need higher vacuum (up to -460 mbar) or pressure (up to 420 mbar) and higher flow capacity than the 2BH1023 can provide. The 2BH1810 also offers a higher motor power (8.6 kW at 50 Hz) for demanding continuous duty. Select a smaller sibling if your required differential pressure and flow are lower, to save energy and space.

What are the requirements for the power supply and motor protection for the 2BH1810?

The motor is rated for 190–210 V at 50 Hz and 460 V Δ at 60 Hz. Use a motor protection circuit breaker set to the rated current (30.8 A at 50 Hz, 31.4 A at 60 Hz) and ensure the supply can handle the starting current. The installation must comply with local electrical codes and the motor's UL/CSA approval.

What are the mounting and environmental limits for the 2BH1810?

Mount the blower horizontally on a rigid, vibration-damped base. The IP55 motor allows operation in dusty and wet environments, but avoid direct water spray. Ambient temperature should be between -20 °C and +40 °C; consult the manual for higher temperatures. Ensure sufficient clearance for cooling air.

What maintenance is required and what consumables are not included?

Regularly inspect and clean the impeller and inlet filter; replace the filter element when clogged. The blower is delivered without filter, silencer, or flexible connectors; these must be ordered separately. Bearing lubrication is not required as the motor uses sealed bearings. Check the manual for the maintenance schedule.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH1810 IE3 vacuum pump (EN)
Datasheet ·309,0 КБ ·2 pp.
View PDF