Elmo Rietschle 2BH1900
Elmo Rietschle 2BH1900 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -190 mbar, Motor power 8.6 kW, Noise level 75 dB.
The 2BH1900 is a side-channel regenerative blower in the Elmo Rietschle G-BH1 series, configured for 50/60 Hz operation with a 17.3/19.9 kW IE3 motor. It delivers up to 410 mbar positive pressure and -350 mbar vacuum at 50 Hz, distinguishing it as the highest-capacity model among the listed siblings (2BH1009 through 2BH1023). It is intended for continuous-duty pressure or vacuum supply in industrial processes requiring oil-free, contact-free gas movement.
Elmo Rietschle G-BH1 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Weight, kg | Max. differential pressure, mbar | Current, A | Protection rating |
|---|---|---|---|---|---|---|
| 2BH1900 Current | 8.6 | 71 | 183 | -190 | 30.8 | IP55 |
| 2BH1009 | — | — | — | — | — | — |
| 2BH1014 | 0.32 | 57 | 11 | -55 | 3.2–6.5 | IP55 |
| 2BH1015 | 1.3 | 64 | 21 | -180 | 8–16 | IP55 |
| 2BH1023 | 1.75 | 69 | 69 | -190 | 10–20 | IP55 |
| 2BH1035 | 2.2 | 64 | 70 | -140 | 14.3–27 | IP55 |
| 2BH1100 | 0.2 | 53 | 10 | -120 | 1.39 Δ / 0.80 Y | IP 55 |
| 2BH1200 | 0.29 | 40 | 57 | -40 | 1.38 0.8 Y | IP55 |
| 2BH1300 | 0.29 | 100 | 51 | -100 | 1.9 | IP 55 |
| 2BH1310 | 0.7 | 56 | 16 | -250 | 3.8 Δ / 2.20 Y | IP55 |
| 2BH1330 | 0.29 | 80 | 51 | — | 1.74 Δ / 1.0 Y | IP55 |
| 2BH1400 | 0.95 | 61 | 16 | -180 | 5.6 | IP55 |
| 2BH1410 | 2 | 65 | 28 | -300 | 6.9 | IP55 |
| 2BH1430 | 1.1 | 64 | 16 | 110 | 4.2 | IP55 |
| 2BH1490 | 0.95 | 61 | 16 | -140 | 4.8 VV | IP55 |
| 2BH1500 | 0.95 | 65 | 21 | -90 | 4.2 | IP55 |
| 2BH1510 | 4 | 71 | 48 | -400 | 7.6–15.2 | IP55 |
| 2BH1530 | 1.6 | 69 | 25 | -90 | 4.7 | IP55 |
| 2BH1590 | 1.3 | 61 | 21 | -190 | 2.75 | IP55 |
| 2BH1600 | 1.75 | 72 | 31 | 130 | 9.9 | IP55 |
| 2BH1610 | 2.5 | 75 | 48 | 160 | 6 | IP55 |
| 2BH1630 | 2.5 | 64 | 36 | -160 | 17.1 | IP55 |
| 2BH1640 | 4.6 | 65 | 65 | -240–260 | 17.1 | IP55 |
| 2BH1690 | 2.5 | 64 | 34 | -200 | 9.9 | IP55 |
| 2BH1800 | 5.8 | 77 | 131 | 260 | 11–22 | IP55 |
| 2BH1810 | 9.9 | 74 | 188 | -460 | 30.8 | IP55 |
| 2BH1830 | 5.8 | 75 | 133 | -160 | 19.4 | IP55 |
| 2BH1910 | 12.6 | 76 | 295 | -220 | 26.4 | IP55 |
| 2BH1930 | 8.6 | 75 | 212 | -80 | 17.6–35.2 | IP55 |
| 2BH1940 | 19.9 | 73 | 303 | -150 | 63.1 | IP55 |
| 2BH1943 | 17.3 | 77 | 330 | -160 | 72.2 UU / 36.1 U | IP55 |
Full specifications
| Max. differential pressure | -190 mbar (50 Hz) 60 Hz: -150 mbar |
| Motor power | 8.6 kW (50 Hz) 60 Hz: 9.9 kW |
| Noise level | 71 dB (50 Hz) 60 Hz: 75 dB |
| Max. differential pressure vacuum mfr | -150 mbar (60 Hz) |
| Type No. mfr | 2BH1900-1AK01 (50 Hz) |
| Type No. mfr | 2BH1900-1AK01 (60 Hz) |
| Weight | 183 kg |
| Current | 30.8 A (50 Hz) 60 Hz: 35.2 A |
| Frequency | 50 Hz |
| Power supply | 3~ 50/60 Hz |
| Voltage | 190-210 V (50 Hz) 60 Hz: 190-210 / 380-420 V |
| Rated voltage mfr | 200 V (60 Hz) |
| Rated current mfr | 35.2 A (60 Hz) |
| Efficiency class mfr | IE3 (50 Hz) |
| Efficiency class mfr | NP (60 Hz) |
| Frequency (alt var) mfr | 60 Hz |
| Protection rating | IP55 |
| Sound pressure level mfr | 71 dB(A) (50 Hz) |
| Sound pressure level mfr | 75 dB(A) (60 Hz) |
Description
Construction and series positioning
- The 2BH1900 is a single-stage side-channel blower with an integrated IE3 efficiency-class motor, IP55 protection, and class F insulation. At approximately 183 kg, it is substantially larger than the sibling models 2BH1009, 2BH1014, 2BH1015, and 2BH1023, and its 17.3 kW (50 Hz) / 19.9 kW (60 Hz) power rating places it at the top of the G-BH1 range shown. The dual-voltage winding (220–240/380–420 V at 50 Hz; 440–480 V at 60 Hz) allows operation on common industrial three-phase supplies without external transformation.
Operating behavior
- Maximum differential pressure is 410 mbar in pressure mode and -350 mbar in vacuum mode at 50 Hz; at 60 Hz these limits are 380 mbar and -380 mbar respectively. The higher frequency increases vacuum capability but slightly reduces maximum pressure, so the intended duty point should be selected against the correct frequency curve. No digitized curve points were supplied, so part-load behavior and flow-versus-pressure characteristics must be obtained from the manufacturer's performance data for this specific model.
Installation and operation
- No PDF manual digest was provided; installation, connection, and control specifics are therefore not documented here. The IP55 rating permits operation in dusty or damp industrial environments, but the motor is air-cooled and requires unobstructed ventilation. Sound pressure is 74 dB(A) at 50 Hz and 78 dB(A) at 60 Hz, so acoustic treatment or hearing protection may be needed depending on installation location and local regulations.
Integration & Operating Notes
The winding is rated 220–240/380–420 V at 50 Hz and 440–480 V at 60 Hz. Connecting the motor to a voltage outside the matching range will cause overheating or loss of torque; verify the terminal-box link configuration against the nameplate before first start.
Operating beyond the maximum differential pressure in either direction increases motor current and internal temperature, risking winding damage and bearing overload. At 60 Hz the limits shift to 380 mbar pressure and -380 mbar vacuum; size the process restriction accordingly.
The IP55 motor relies on fan-driven air over its fins. Install the blower with sufficient clearance around the fan cowl and avoid recirculating hot exhaust air; ambient temperature and altitude derating data are not supplied and should be confirmed with the manufacturer for continuous full-load operation.
The document digests contain no service intervals, error codes, or consumable lists. Bearing lubrication, filter replacement (if inlet filtration is fitted), and impeller clearance checks should be scheduled according to Elmo Rietschle's G-BH1 series maintenance instructions for this frame size.
Selection & Integration Q&A
Choose the 2BH1900 when the duty point requires up to 410 mbar pressure or -350 mbar vacuum at 50 Hz with a 17.3 kW motor. The smaller siblings suit lower flow or pressure demands; the 2BH1900 is the highest-capacity listed model and should be selected only when their limits are insufficient.
It needs a three-phase supply matching the winding link: 220–240/380–420 V at 50 Hz or 440–480 V at 60 Hz. Provide a motor-protection circuit breaker or overload relay set to the rated current (57.0/32.7 A at 50 Hz; 32.4 A at 60 Hz) and a contactor rated for the 17.3–19.9 kW load.
No maintenance schedule, spare-parts list, inlet filter, silencer, flexible connectors, or mounting pads are included in the supplied facts. Establish bearing and filter service intervals from the G-BH1 manual, and specify suction/discharge silencers and vibration isolators separately to meet noise and piping-load requirements.