Peter Huber Kältemaschinenbau Unistat 915w Dynamisches
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unistat 915w Dynamisches

Peter Huber Kältemaschinenbau Unistat 915w Dynamisches — Temperature control units with Noise level 64 dB.

Water-cooled Unistat 915w Dynamisches with magnetically coupled stainless-steel pump, covering -90 to 250 °C at 6 kW heating and 110 l/min max flow. The 'w' suffix denotes water cooling, distinguishing it from air-cooled siblings; the 'Dynamisches' variant targets dynamic temperature ramps. Intended for closed-loop process temperature control in pilot and production systems.

Noise level
64 dB

Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection

Model Noise level, dBAmbient temperature limit, °CDisplay resolutionPower supplyPump connectionPump type
Unistat 915w Dynamisches Current 645–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat 1005w Dynamisches —5–400, 01400V 3~ 50HzM30x1, 5 AG malePressure pump, variable
Unistat 1015w Dynamisches —5–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat 705w Dynamisches —5–400, 01230V 1~ 50HzM24x1, 5 AG malePressure pump, variable
Unistat 815w Dynamisches 605–400, 01400V 3~ 50HzM30x1, 5 AG malePressure pump, variable
Unistat 825w Dynamisches —5–400, 01400V 3~ 50HzM30x1, 5 AG malePressure pump, variable
Unistat 905w Dynamisches —5–400, 01 K208V 3~ 60HzM30x1, 5 AG malemagnetically coupled, st
Unistat 912w Dynamisches 655–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat 920w Dynamisches 715–400, 01400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st
Unistat 930w Dynamisches —5–400, 01460V 3~ 60HzM38x1, 5 AG malemagnetically coupled, st
Unistat 950w Dynamisches —5–400, 01400V 3~ 50Hzflange DN40 PN10/40 EN10magnetically coupled, st
Unistat P815 Dynamisches 645–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat P815w Dynamisches —5–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat P825 Dynamisches —5–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat P825w Dynamisches —5–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat P905 Dynamisches —5–350, 01460V 3~ 60HzM30x1, 5 AG malemagnetically coupled, st
Unistat P905w Dynamisches —5–400, 01460V 3~ 60HzM30x1, 5 AG malemagnetically coupled, st
Unistat P912w Dynamisches 655–400, 01460V 3~ 60HzM30x1, 5 AG malemagnetically coupled, st
Unistat P915w Dynamisches 645–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat P920w Dynamisches —5–400, 01400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st
Unistat P925w Dynamisches —5–400, 01400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st
Unistat P930w Dynamisches —5–400, 01400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st
Unistat P950w Dynamisches —5–400, 01400V 3~ 50Hzflange DN40 PN10/40 EN10magnetically coupled, st

Full specifications

Core Performance & Functional Specifications
Noise level 64 dB(A)
Control output POKO ONE
Heating capacity 6 kW
Maximum delivery flow rate 110 l/min (1, 5 bar)
Pump connection M30x1, 5 AG male
Pump speed adjustable Yes
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range -90...250 °C
Dimensions, Weight & Mechanical Design
Weight 362 kg
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Maximum viscosity 50 mm²/s
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G3/4 male
Cooling water consumption 720 l/h (at 15°C, flow 0°C)
Cooling water differential pressure 1 bar (min)
Cooling Water Pressure 6 bar (max)
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Behavior under load and media

Installation, connection and control

Integration & Operating Notes

Electrical
Site must provide 400 V 3~ 50 Hz with 3x32 A fusing

The unit draws up to 28.5 A per datasheet; the electrical installation, cable cross-section and protection device must be sized for this. A plug is not included for three-phase devices under 63 A, so a matching plug must be procured and wired by an electrician. Voltage tolerance is ±5% only with simultaneous frequency tolerance of ±2%.

Datasheet, Technical Specifications; Operation Manual, Section 'Preparations for operation and application/power connection'
Cooling & Media
Cooling water must be 5–20 °C at 1–6 bar differential

Supply cooling water within 5–20 °C intake, minimum 1 bar differential pressure and maximum 6 bar. Consumption is 720 l/h at 15 °C water and 0 °C flow. Cooling power decreases and flow demand may rise as water temperature increases. Circuit materials include copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only compatible water may be used. Insulate pipes if below dew point.

Datasheet, Technical Specifications; Operation Manual, Section 1.4.1
Process Limits
Heat transfer fluid viscosity must not exceed 50 mm²/s

The pump and circuit are limited to fluids with maximum kinematic viscosity of 50 mm²/s. For FL-rated fluids, fire point must be ≥65 °C; ethanol requires supervised operation. Minimum filling capacity is 3.9 l; ensure adequate venting — air in the circuit can interrupt low-level protection and stop circulation.

Datasheet, Technical Specifications; Operation Manual, Section 1.7
Control & I/O
Process Safety mode requires compressor set to Permanently ON

In Process Safety mode, reaching the overtemperature trigger releases maximum cooling instead of switching off all poles. This requires the compressor to be configured as Permanently ON. Power-failure restart behavior is selectable (Off/Standby or ON/temperature control active); choose according to whether unattended restart is acceptable.

Operation Manual, Section 1.7.2 and 1.8.1

Selection & Integration Q&A

When should I choose the Unistat 915w Dynamisches instead of the 815w or 1005w Dynamisches?

The 915w sits between the 815w (60 dB(A) noise) and 1005w in the water-cooled dynamic series. Choose 915w when its 6 kW heating and 110 l/min flow match your load; step to 1005w for higher capacity or down to 815w for lower noise/space. All are water-cooled ('w').

What cooling water supply and quality does the 915w require?

Supply 5–20 °C water at 1–6 bar differential, 720 l/h at 15 °C/0 °C flow. Circuit materials include copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM; use compatible water. Insulate pipes if below dew point.

Can the 915w be installed in a standard laboratory room, and what are the duty limits?

Yes, indoors only (IP20, 5–40 °C ambient), not in an ATEX zone. Transport upright; allow ~2 h acclimation after temperature change. For closed applications keep expansion vessel unlocked; for open bath lock it. Shut off cooling water overnight.

What maintenance and accessories are required beyond the base unit?

A matching 400 V plug must be provided (cable included, plug not). Periodic hose inspection and replacement, cleaning of liquefier fins and strainer, and refrigerant work by approved contractors. A drip tray is required below the unit. Heat transfer fluid and cooling water hoses are not included.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unistat 915w Temperature Control System
Datasheet ·79,3 КБ ·2 pp.
View PDF
PDF
Unistat® Operation Manual — Unistat® 5, Unistat® Pilot ONE®
Manual ·3,6 МБ ·100 pp.
View PDF
PDF
Unistat Operation Manual
Manual ·3,7 МБ ·102 pp.
View PDF