Peter Huber Kältemaschinenbau Unistat 915w Dynamisches
Peter Huber Kältemaschinenbau Unistat 915w Dynamisches — Temperature control units with Noise level 64 dB.
Water-cooled Unistat 915w Dynamisches with magnetically coupled stainless-steel pump, covering -90 to 250 °C at 6 kW heating and 110 l/min max flow. The 'w' suffix denotes water cooling, distinguishing it from air-cooled siblings; the 'Dynamisches' variant targets dynamic temperature ramps. Intended for closed-loop process temperature control in pilot and production systems.
Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection
| Model | Noise level, dB | Ambient temperature limit, °C | Display resolution | Power supply | Pump connection | Pump type |
|---|---|---|---|---|---|---|
| Unistat 915w Dynamisches Current | 64 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 1005w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | Pressure pump, variable |
| Unistat 1015w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 705w Dynamisches | — | 5–40 | 0, 01 | 230V 1~ 50Hz | M24x1, 5 AG male | Pressure pump, variable |
| Unistat 815w Dynamisches | 60 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | Pressure pump, variable |
| Unistat 825w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | Pressure pump, variable |
| Unistat 905w Dynamisches | — | 5–40 | 0, 01 K | 208V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 912w Dynamisches | 65 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 920w Dynamisches | 71 | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat 930w Dynamisches | — | 5–40 | 0, 01 | 460V 3~ 60Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat 950w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | flange DN40 PN10/40 EN10 | magnetically coupled, st |
| Unistat P815 Dynamisches | 64 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P815w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P825 Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P825w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P905 Dynamisches | — | 5–35 | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P905w Dynamisches | — | 5–40 | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P912w Dynamisches | 65 | 5–40 | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P915w Dynamisches | 64 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P920w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat P925w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat P930w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat P950w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | flange DN40 PN10/40 EN10 | magnetically coupled, st |
Full specifications
| Noise level | 64 dB(A) |
| Control output | POKO ONE |
| Heating capacity | 6 kW |
| Maximum delivery flow rate | 110 l/min (1, 5 bar) |
| Pump connection | M30x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | -90...250 °C |
| Weight | 362 kg |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 50 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G3/4 male |
| Cooling water consumption | 720 l/h (at 15°C, flow 0°C) |
| Cooling water differential pressure | 1 bar (min) |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Free-standing water-cooled unit (suffix 'w') in the Unistat 9xx series; siblings 705w, 815w, 1005w and 1015w differ in cooling capacity and footprint. The 'Dynamisches' designation indicates suitability for dynamic temperature changes; the manual warns that very dynamic, high-temperature changes recurring at short intervals can fatigue the plate heat exchanger (this warning does not apply to models without a plate heat exchanger, but the 915w is not listed among those).
- Pump: magnetically coupled, stainless steel, speed-adjustable, with M30x1.5 male pump connection. Cooling water connections are G3/4 male.
- Safety class III / FL per DIN 12876 with adjustable overtemperature protection; Pilot ONE controller with POKO ONE control output.
Behavior under load and media
- Temperature range -90 to 250 °C; heating capacity 6 kW. Pump delivers max 110 l/min at 1.5 bar; 31 l/min at 1.4 bar per datasheet. Maximum permissible kinematic viscosity of heat transfer fluid is 50 mm²/s.
- Cooling water: intake 5–20 °C, min differential pressure 1 bar, max pressure 6 bar, consumption 720 l/h at 15 °C water / 0 °C flow. Cooling power drops as cooling water temperature rises, and required flow may increase.
- Minimum filling capacity 3.9 l; expansion tank 6.5 l. For externally closed applications the expansion vessel must remain unlocked; for externally open (bath) applications it must be locked.
Installation, connection and control
- Power: 400 V 3~ 50 Hz, max current 28.5 A, fuse 3x32 A. Three-phase devices under 63 A are delivered with cable but without plug; a suitable plug must be provided on site. Voltage tolerance ±5% with simultaneous frequency tolerance ±2%.
- Ambient 5–40 °C; IP20, dry indoor location only. Unit must not be installed in an ATEX zone. Transport upright only; allow ~2 h acclimation after temperature change before power-on.
- Controller: Pilot ONE with Ethernet, USB (host and device) and RS232; external Pt100 sensor connection; display resolution 0.01 K. Power-failure behavior configurable (Off/Standby default or ON/temperature control active). Process Safety mode requires compressor set to Permanently ON.
- Cooling water pipes must be insulated if water temperature can fall below dew point. Shut off cooling water during downtimes (e.g. overnight).
Integration & Operating Notes
The unit draws up to 28.5 A per datasheet; the electrical installation, cable cross-section and protection device must be sized for this. A plug is not included for three-phase devices under 63 A, so a matching plug must be procured and wired by an electrician. Voltage tolerance is ±5% only with simultaneous frequency tolerance of ±2%.
Supply cooling water within 5–20 °C intake, minimum 1 bar differential pressure and maximum 6 bar. Consumption is 720 l/h at 15 °C water and 0 °C flow. Cooling power decreases and flow demand may rise as water temperature increases. Circuit materials include copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only compatible water may be used. Insulate pipes if below dew point.
The pump and circuit are limited to fluids with maximum kinematic viscosity of 50 mm²/s. For FL-rated fluids, fire point must be ≥65 °C; ethanol requires supervised operation. Minimum filling capacity is 3.9 l; ensure adequate venting — air in the circuit can interrupt low-level protection and stop circulation.
In Process Safety mode, reaching the overtemperature trigger releases maximum cooling instead of switching off all poles. This requires the compressor to be configured as Permanently ON. Power-failure restart behavior is selectable (Off/Standby or ON/temperature control active); choose according to whether unattended restart is acceptable.
Selection & Integration Q&A
The 915w sits between the 815w (60 dB(A) noise) and 1005w in the water-cooled dynamic series. Choose 915w when its 6 kW heating and 110 l/min flow match your load; step to 1005w for higher capacity or down to 815w for lower noise/space. All are water-cooled ('w').
Supply 5–20 °C water at 1–6 bar differential, 720 l/h at 15 °C/0 °C flow. Circuit materials include copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM; use compatible water. Insulate pipes if below dew point.
Yes, indoors only (IP20, 5–40 °C ambient), not in an ATEX zone. Transport upright; allow ~2 h acclimation after temperature change. For closed applications keep expansion vessel unlocked; for open bath lock it. Shut off cooling water overnight.
A matching 400 V plug must be provided (cable included, plug not). Periodic hose inspection and replacement, cleaning of liquefier fins and strainer, and refrigerant work by approved contractors. A drip tray is required below the unit. Heat transfer fluid and cooling water hoses are not included.