Data sheet 2BH1 330: side channel blower with integrated frequency converter (IP55), 2BH1330-1A221 and 2BH1330-1AP16 variants; VFD types A–K (2FC4xxx-1□□00) and VFD accessories.

Technical Data

Parameter Value Condition
Rated voltage 345 V p.2 ↗ 2BH1330-1A221, 87 Hz, delta
Rated current 2,8 A p.2 ↗ 2BH1330-1A221, 87 Hz, delta
Rated motor power 0,95 kW p.2 ↗ 2BH1330-1A221, 87 Hz
Max. differential pressure, vacuum -130 mbar p.2 ↗ 2BH1330-1A221, 87 Hz
Max. differential pressure, pressure 120 mbar p.2 ↗ 2BH1330-1A221, 87 Hz
Sound pressure level 62 dB(A) p.2 ↗ 2BH1330-1A221, 87 Hz
Weight 16 kg p.2 ↗ 2BH1330-1A221, 87 Hz
Max. differential pressure, vacuum -80 mbar p.2 ↗ 2BH1330-1A221, 37 Hz
Max. differential pressure, pressure 90 mbar p.2 ↗ 2BH1330-1A221, 37 Hz
Max. differential pressure, vacuum -110 mbar p.2 ↗ 2BH1330-1A221, 50 Hz
Max. differential pressure, pressure 110 mbar p.2 ↗ 2BH1330-1A221, 50 Hz
Sound pressure level 53 dB(A) p.2 ↗ 2BH1330-1A221, 50 Hz
Weight 11 kg p.2 ↗ 2BH1330-1A221, 50 Hz
Max. differential pressure, vacuum -90 mbar p.2 ↗ 2BH1330-1A221, 60 Hz
Max. differential pressure, pressure 90 mbar p.2 ↗ 2BH1330-1A221, 60 Hz
Sound pressure level 56 dB(A) p.2 ↗ 2BH1330-1A221, 60 Hz
Rated voltage 400 V p.2 ↗ 2BH1330-1AP16, 87 Hz
Rated current 1,65 A p.2 ↗ 2BH1330-1AP16, 87 Hz
Rated motor power 0,64 kW p.2 ↗ 2BH1330-1AP16, 87 Hz
Max. differential pressure, vacuum -70 mbar p.2 ↗ 2BH1330-1AP16, 87 Hz
Max. differential pressure, pressure 60 mbar p.2 ↗ 2BH1330-1AP16, 87 Hz

Operating Limits

  • Max. suction and ambient temperature for stated pressure differences: 25 °C p.1 ↗
  • Min. mains voltage for frequency converter: 380 V p.1 ↗
  • Min. pulse frequency for performance curves: 4 kHz p.1 ↗
  • Performance curve tolerance: ±10 % p.1 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH1330 Blower type/size designation
7-11 p.2 ↗ 1A221 Motor/voltage variant (345 V, 87 Hz, delta)
7-11 p.2 ↗ 1AP16 Motor/voltage variant (400 V, 87 Hz)
VFD type field p.2 ↗ A–K Frequency converter size (2FC4xxx-1□□00)