Technical Data Sheet — G-BH1 2BH1400 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

G-BH1 side channel blower data sheet 2BH1 400; covers 2BH1400-1AH06, 2BH1400-1AC03, 2BH1400-7AV25 and the 2BH1400-..□.□ motor voltage variants (H1, H6, H7, C3, C5, P3, P5, P6, P7) at 50 Hz and 60 Hz

Technical Data

Parameter Value Condition
Rated pressure 0,70 kW p.2 ↗ 2BH1400-1AH06, 50 Hz
Voltage 200-240 Δ / 345-415 Y V p.2 ↗ 2BH1400-1AH06, 50 Hz
Current 3,8 Δ / 2,20 Y A p.2 ↗ 2BH1400-1AH06, 50 Hz
Max. differential pressure vacuum -120 mbar p.2 ↗ 2BH1400-1AH06, 50 Hz
Max. differential pressure pressure 120 mbar p.2 ↗ 2BH1400-1AH06, 50 Hz
Sound pressure level 63 dB(A) p.2 ↗ 2BH1400-1AH06, 50 Hz
Weight 14 kg p.2 ↗ 2BH1400-1AH06, 50 Hz
Power 0,83 kW p.2 ↗ 2BH1400-1AH06, 60 Hz
Voltage 220-275 Δ / 380-480 Y V p.2 ↗ 2BH1400-1AH06, 60 Hz
Current 3,75 Δ / 2,15 Y A p.2 ↗ 2BH1400-1AH06, 60 Hz
Max. differential pressure vacuum -130 mbar p.2 ↗ 2BH1400-1AH06, 60 Hz
Max. differential pressure pressure 130 mbar p.2 ↗ 2BH1400-1AH06, 60 Hz
Sound pressure level 64 dB(A) p.2 ↗ 2BH1400-1AH06, 60 Hz
Weight 14 kg p.2 ↗ 2BH1400-1AH06, 60 Hz
Power 0,70 kW p.2 ↗ 2BH1400-1AC03, 50 Hz
Voltage 500 Y V p.2 ↗ 2BH1400-1AC03, 50 Hz
Current 1,49 Y A p.2 ↗ 2BH1400-1AC03, 50 Hz
Max. differential pressure vacuum -120 mbar p.2 ↗ 2BH1400-1AC03, 50 Hz
Max. differential pressure pressure 120 mbar p.2 ↗ 2BH1400-1AC03, 50 Hz
Sound pressure level 63 dB(A) p.2 ↗ 2BH1400-1AC03, 50 Hz
Weight 14 kg p.2 ↗ 2BH1400-1AC03, 50 Hz
Power 1,1 kW p.2 ↗ 2BH1400-7AV25, 50 Hz
Voltage 115 V p.2 ↗ 2BH1400-7AV25, 50 Hz
Current 13,0 / 6,5 A p.2 ↗ 2BH1400-7AV25, 50 Hz
Max. differential pressure vacuum -150 mbar p.2 ↗ 2BH1400-7AV25, 50 Hz

Operating Limits

  • Max. suction and ambient temperature for stated total pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Frequency tolerance: +/- 2 % maximum p.2 ↗
  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗

Type Code Decoder

Position Token Meaning
1-7 p.2 ↗ 2BH1400 Type/size designation of the side channel blower
11-12 p.2 ↗ H1 / H6 / H7 / C3 / C5 / P3 / P5 / P6 / P7 Motor voltage/frequency variant code (see ordering table)
field 1 p.2 ↗ H Motor series H (voltage range 185-225 Δ / 320-390 Y at 50 Hz etc.)
field 2 p.2 ↗ 1 Variant number within H series (H1: 200-240 Δ / 345-415 Y at 50 Hz)
field 1 p.2 ↗ C Motor series C (500 Y / 575 Y fixed voltage)
field 2 p.2 ↗ 3 Variant number within C series (C3: 500 Y at 50 Hz)
field 1 p.2 ↗ P Motor series P (D/Y voltage ranges, e.g. 200-260 D / 350-450 Y)
field 2 p.2 ↗ 3 / 5 / 6 / 7 Variant number within P series (P3: 450-550 Y; P5: 450-550 D; P6: 200-260 D / 350-450 Y; P7: 350-450 D / 610-725 Y)