Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — G-BH1 2BH1600 ATEX vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH1 600: side channel blower in ATEX configuration (G-BH1 N), sizes 2BH1600, ATEX categories 3GD, 3/2D and 3/2G, fixed voltage machines for 50 Hz and 60 Hz; ordering code 2BH1…-1.□.□-Z with Z=M34/M74/M71 and voltage/ATEX field substitutions.

Technical Data

Parameter Value Condition
Rated voltage 400 / 690 V p.2 ↗ 2BH1600, 50 Hz, Δ/Y
Rated voltage 460 V p.2 ↗ 2BH1600, 60 Hz, Δ
Current 4.20 / 2.40 A p.2 ↗ 2BH1600, 50 Hz, Δ/Y
Current 4.20 A p.2 ↗ 2BH1600, 60 Hz, Δ
Power 3.0 hp p.2 ↗ 2BH1600, 50 Hz
Power 3.4 hp p.2 ↗ 2BH1600, 60 Hz
Max. vacuum -68.25 inch H2O p.2 ↗ 2BH1600, 50 Hz
Max. vacuum -56.2 inch H2O p.2 ↗ 2BH1600, 60 Hz
Max. differential pressure 60.2 inch H2O p.2 ↗ 2BH1600, 50 Hz
Max. differential pressure 52.1 inch H2O p.2 ↗ 2BH1600, 60 Hz
Sound pressure level 69 dB(A) p.2 ↗ 2BH1600, 50 Hz
Sound pressure level 69 dB(A) p.2 ↗ 2BH1600, 60 Hz
Weight 168 lbs p.2 ↗ 2BH1600, 50 Hz
Weight 187 lbs p.2 ↗ 2BH1600, 60 Hz
Degree of protection IP55 p.2 ↗ 2BH1600
ATEX category 3/2G p.2 ↗ 2BH1600, 50 Hz
ATEX category 3/2D, 3GD p.2 ↗ 2BH1600, 50 Hz
ATEX category 3/2G p.2 ↗ 2BH1600, 60 Hz
ATEX category 3/2D, 3GD p.2 ↗ 2BH1600, 60 Hz

Operating Limits

  • Performance curve reference air temperature: 59 °F p.1 ↗
  • Performance curve reference atmospheric pressure: 29.92 inch Hg p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Degree of protection: IP55 p.2 ↗
  • ATEX category 3GD marking: II 3G IIB T3 Gc and II 3D T125°C Dc p.2 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH1 Series G-BH1 side channel blower
5-7 p.2 ↗ 600 Size 600
field 1 p.2 ↗ 1 Version field (fixed as 1 in printed code)
field 2 p.2 ↗ D Voltage/connection variant: D = 230 Δ/400 Y or 400 Δ/690 Y or 500 Δ (50 Hz), 460 Δ or 575 Δ (60 Hz)
field 2 p.2 ↗ G Voltage/connection variant: G = 460 Y or 460 Δ or 575 Δ (60 Hz only)
field 3 p.2 ↗ 1 Voltage code: 230 Δ/400 Y (50 Hz) or 460 Y (60 Hz)
field 3 p.2 ↗ 6 Voltage code: 400 Δ/690 Y (50 Hz) or 460 Δ (60 Hz)
field 3 p.2 ↗ 5 Voltage code: 500 Δ (50 Hz) or 575 Δ (60 Hz)