Technical Data Sheet — G-BH1 2BH1630 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Side channel blower type 2BH1 630 (G-BH1 series), 50 Hz and 60 Hz variants, voltage ranges 185-225 D / 320-390 Y, 200-240 D / 345-415 Y, 345-415 D / 600-720 Y, 500 Y, 500 D, 475-525 V Y, 475-525 V D, fixed-voltage and VFD (87 Hz) versions; order numbers 2BH1630-1AH26, 2BH1630-1AH36, 2BH1630-1AC23, 2BH1630-1AC33; suction-port-at-blower-cover order code 2BH1630-1E□□□
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated frequency | 50 Hz p.2 ↗ | 2BH1630-1AH26 |
| Voltage | 200-240 / 345-415 Y V p.2 ↗ | 2BH1630-1AH26, 50 Hz |
| Current | 12,5 / 7,2 Y A p.2 ↗ | 2BH1630-1AH26, 50 Hz |
| Power | 3,0 kW p.2 ↗ | 2BH1630-1AH26, 50 Hz |
| Max. differential pressure vacuum | -220 mbar p.2 ↗ | 2BH1630-1AH26, 50 Hz |
| Max. differential pressure pressure | 200 mbar p.2 ↗ | 2BH1630-1AH26, 50 Hz |
| Sound pressure level | 38 dB(A) p.2 ↗ | 2BH1630-1AH26, 50 Hz |
| Weight | 38 kg p.2 ↗ | 2BH1630-1AH26 |
| Rated frequency | 60 Hz p.2 ↗ | 2BH1630-1AH26 |
| Voltage | 220-275 / 380-480 Y V p.2 ↗ | 2BH1630-1AH26, 60 Hz |
| Current | 12,6 / 7,3 Y A p.2 ↗ | 2BH1630-1AH26, 60 Hz |
| Power | 3,45 kW p.2 ↗ | 2BH1630-1AH26, 60 Hz |
| Max. differential pressure vacuum | -200 mbar p.2 ↗ | 2BH1630-1AH26, 60 Hz |
| Max. differential pressure pressure | 170 mbar p.2 ↗ | 2BH1630-1AH26, 60 Hz |
| Power | 4,0 kW p.2 ↗ | 2BH1630-1AH36, 50 Hz |
| Max. differential pressure vacuum | -260 mbar p.2 ↗ | 2BH1630-1AH36, 50 Hz |
| Max. differential pressure pressure | 290 mbar p.2 ↗ | 2BH1630-1AH36, 50 Hz |
| Sound pressure level | 48 dB(A) p.2 ↗ | 2BH1630-1AH36, 50 Hz |
| Weight | 48 kg p.2 ↗ | 2BH1630-1AH36 |
| Power | 3,0 kW p.2 ↗ | 2BH1630-1AC23, 50 Hz |
| Max. differential pressure vacuum | -220 mbar p.2 ↗ | 2BH1630-1AC23, 50 Hz |
| Max. differential pressure pressure | 200 mbar p.2 ↗ | 2BH1630-1AC23, 50 Hz |
| Power | 4,0 kW p.2 ↗ | 2BH1630-1AC33, 50 Hz |
| Max. differential pressure vacuum | -260 mbar p.2 ↗ | 2BH1630-1AC33, 50 Hz |
| Max. differential pressure pressure | 290 mbar p.2 ↗ | 2BH1630-1AC33, 50 Hz |
Operating Limits
- Max. ambient / suction temperature for stated total pressure differences: 25 °C p.1 ↗
- Performance curve tolerance: ±10 % p.1 ↗
- Protection category: IP 55 p.1 ↗
- Insulation class: F p.1 ↗
- Frequency tolerance: +/- 2 % maximum p.2 ↗
- Max. converter input voltage for standard motor insulation: 460 V p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-7 p.2 ↗ | 2BH1630 | Type / size designation (side channel blower 2BH1 630) |
| field 1 p.2 ↗ | H / C | Voltage range group: H = 185-225 D / 320-390 Y (50 Hz) and 200-240 D / 345-415 Y (60 Hz); C = 500 Y (50 Hz) and 575 Y (60 Hz) |
| field 2 p.2 ↗ | 1 / 6 / 7 / 3 / 5 | Voltage variant within the group (e.g. H1, H6, H7, C3, C5) |
| field 3 p.2 ↗ | A / K / Q | Motor / voltage option: A = standard voltage range, K = fixed voltage, Q = 475-525 V Y / 550-600 V Y or 475-525 V D / 550-600 V D |
| field 4 p.2 ↗ | 2 / 3 | Power size: 2 = 3,0 kW (50 Hz) / 3,45 kW (60 Hz); 3 = 4,0 kW (50 Hz) / 4,6 kW (60 Hz) |
| field 5 p.2 ↗ | 6 / 3 | Voltage code: 6 = 200-240 D / 345-415 Y (50 Hz) and 220-275 D / 380-480 Y (60 Hz); 3 = 500 Y (50 Hz) and 575 Y (60 Hz) |
| field 6 p.2 ↗ | □ | Placeholder for voltage / frequency option in ordering code 2BH1630-..□.□ |
| field 7 p.2 ↗ | □ | Placeholder for second option field in ordering code 2BH1630-..□.□ |
Ordering Data
| Ordering Code | Part No. | Variant / Code | Applies To | Note |
|---|---|---|---|---|
| 2BH1630-1AH26 p.2 ↗ | 2BH1630-1AH26 | 50 Hz / 60 Hz, 200-240 D / 345-415 Y (50 Hz), 220-275 D / 380-480 Y (60 Hz) | 3,0 kW at 50 Hz, 3,45 kW at 60 Hz | |
| 2BH1630-1AH36 p.2 ↗ | 2BH1630-1AH36 | 50 Hz / 60 Hz, 200-240 D / 345-415 Y (50 Hz), 220-275 D / 380-480 Y (60 Hz) | 4,0 kW at 50 Hz, 4,6 kW at 60 Hz | |
| 2BH1630-1AC23 p.2 ↗ | 2BH1630-1AC23 | 50 Hz / 60 Hz, 500 Y (50 Hz), 575 Y (60 Hz) | 3,0 kW at 50 Hz, 3,45 kW at 60 Hz | |
| 2BH1630-1AC33 p.2 ↗ | 2BH1630-1AC33 | 50 Hz / 60 Hz, 500 Y (50 Hz), 575 Y (60 Hz) | 4,0 kW at 50 Hz, 4,6 kW at 60 Hz |
Related models
Elmo Rietschle 2BH1009
Elmo Rietschle 2BH1014
Elmo Rietschle 2BH1015
Elmo Rietschle 2BH1023
Elmo Rietschle 2BH1035
Elmo Rietschle 2BH1100
Elmo Rietschle 2BH1200
Elmo Rietschle 2BH1300
Elmo Rietschle 2BH1310
Elmo Rietschle 2BH1330
Elmo Rietschle 2BH1400
Elmo Rietschle 2BH1410
Elmo Rietschle 2BH1430
Elmo Rietschle 2BH1490
Elmo Rietschle 2BH1500
Elmo Rietschle 2BH1510
Elmo Rietschle 2BH1530
Elmo Rietschle 2BH1590
Elmo Rietschle 2BH1600
Elmo Rietschle 2BH1610
Elmo Rietschle 2BH1630
Elmo Rietschle 2BH1640
Elmo Rietschle 2BH1690
Elmo Rietschle 2BH1800
Elmo Rietschle 2BH1810
Elmo Rietschle 2BH1830
Elmo Rietschle 2BH1900
Elmo Rietschle 2BH1910
Elmo Rietschle 2BH1930
Elmo Rietschle 2BH1940
Elmo Rietschle 2BH1943