Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — G-BH1 2BH1800 ATEX vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH1 800: side channel blower in ATEX configuration, G-BH1 N series. Covers 2BH1800 variants for 50 Hz and 60 Hz, ATEX categories 3GD, 3/2D and 3/2G, with fixed-voltage motors and alternative voltages.

Technical Data

Parameter Value Condition
Rated voltage 400 / 690 V p.2 ↗ 2BH1800, 50 Hz, delta/Y
Rated current 13,1 / 7,6 A p.2 ↗ 2BH1800, 50 Hz, delta/Y
Power 10,1 hp p.2 ↗ 2BH1800, 50 Hz
Max. vacuum -128 inch H2O p.2 ↗ 2BH1800, 50 Hz
Max. differential pressure 161 inch H2O p.2 ↗ 2BH1800, 50 Hz
Sound pressure level 73 dB(A) p.2 ↗ 2BH1800, 50 Hz
Rated voltage 460 V p.2 ↗ 2BH1800, 60 Hz, delta
Rated current 13,0 A p.2 ↗ 2BH1800, 60 Hz, delta
Power 11,5 hp p.2 ↗ 2BH1800, 60 Hz
Max. vacuum -141 inch H2O p.2 ↗ 2BH1800, 60 Hz
Max. differential pressure 141 inch H2O p.2 ↗ 2BH1800, 60 Hz
Sound pressure level 73 dB(A) p.2 ↗ 2BH1800, 60 Hz
Weight 71 lbs p.2 ↗ 2BH1800
Rated voltage 460 V p.2 ↗ 2BH1800-1AG26-Z, 60 Hz
Rated current 8,9 A p.2 ↗ 2BH1800-1AG26-Z, 60 Hz
Power 7,4 hp p.2 ↗ 2BH1800-1AG26-Z, 60 Hz
Max. vacuum 76 inch H2O p.2 ↗ 2BH1800-1AG26-Z, 60 Hz
Max. differential pressure 76 inch H2O p.2 ↗ 2BH1800-1AG26-Z, 60 Hz
Sound pressure level 71 dB(A) p.2 ↗ 2BH1800-1AG26-Z, 60 Hz
Weight 71 lbs p.2 ↗ 2BH1800-1AG26-Z

Operating Limits

  • ATEX category 3GD: II 3G IIB T3 Gc and II 3D IIIB T125°C Dc p.2 ↗
  • ATEX category 3/2D: II 3/2D IIIC T125°C Dc/Db p.2 ↗
  • ATEX category 3/2G: II 3/2G IIB T3 Gc/Gb p.2 ↗
  • Motor thermal class: F (IE3) p.2 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH180 Series and size (2BH1 800 side channel blower)