Technical Data Sheet — G-BH1 2BH1800 IE3 side channel blower (EN)
Technical Reference Summary
Covered Models & Document Scope
Data sheet 2BH1 800: side channel blower with integrated frequency converter (VFD). Covers VFD types G (2BH1800-1A316, 2BH1800-1A326) and F (2BH1800-1AK06, 2BH1800-1AK16, 2BH1800-1AK26), 3~ 400 V integrated VFD, 50/60 Hz, IP55.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated motor voltage | 370 V p.2 ↗ | 2BH1800-1A316, 85 Hz |
| Rated motor current | 21,5 A p.2 ↗ | 2BH1800-1A316, 85 Hz |
| Rated motor power | 10,2 kW p.2 ↗ | 2BH1800-1A316, 85 Hz |
| Max. differential pressure vacuum | -220 mbar p.2 ↗ | 2BH1800-1A316, 85 Hz |
| Max. differential pressure pressure | 180 mbar p.2 ↗ | 2BH1800-1A316, 85 Hz |
| Sound pressure level | 79/80 dB(A) p.2 ↗ | 2BH1800-1A316, 85 Hz |
| Weight | 119 kg p.2 ↗ | 2BH1800-1A316 |
| Rated motor voltage | 380 V p.2 ↗ | 2BH1800-1A326, 85 Hz |
| Rated motor current | 27,4 A p.2 ↗ | 2BH1800-1A326, 85 Hz |
| Rated motor power | 14,0 kW p.2 ↗ | 2BH1800-1A326, 85 Hz |
| Max. differential pressure vacuum | -380 mbar p.2 ↗ | 2BH1800-1A326, 85 Hz |
| Max. differential pressure pressure | 320 mbar p.2 ↗ | 2BH1800-1A326, 85 Hz |
| Sound pressure level | 79/80 dB(A) p.2 ↗ | 2BH1800-1A326, 85 Hz |
| Weight | 158 kg p.2 ↗ | 2BH1800-1A326 |
| Rated motor voltage | 400 V p.2 ↗ | 2BH1800-1AK06, 85 Hz |
| Rated motor current | 14,4 A p.2 ↗ | 2BH1800-1AK06, 85 Hz |
| Rated motor power | 7,5 kW p.2 ↗ | 2BH1800-1AK06, 85 Hz |
| Max. differential pressure vacuum | -90 mbar p.2 ↗ | 2BH1800-1AK06, 85 Hz |
| Max. differential pressure pressure | 80 mbar p.2 ↗ | 2BH1800-1AK06, 85 Hz |
| Sound pressure level | 79/80 dB(A) p.2 ↗ | 2BH1800-1AK06, 85 Hz |
| Weight | 113 kg p.2 ↗ | 2BH1800-1AK06 |
| Rated motor voltage | 400 V p.2 ↗ | 2BH1800-1AK16, 85 Hz |
| Rated motor current | 20,0 A p.2 ↗ | 2BH1800-1AK16, 85 Hz |
| Rated motor power | 10,2 kW p.2 ↗ | 2BH1800-1AK16, 85 Hz |
| Max. differential pressure vacuum | -220 mbar p.2 ↗ | 2BH1800-1AK16, 85 Hz |
Operating Limits
- Max. ambient/suction temperature for stated pressure differences: 25 °C p.1 ↗
- Min. mains voltage for frequency converter: 380 V p.1 ↗
- Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
- Protection class: IP55 p.2 ↗
- Insulation material class: F p.2 ↗
- VFD mains voltage range: 3~ 400 V -15% … 480 V +10% p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-6 p.2 ↗ | 2BH1800 | Type designation: side channel blower 2BH1, size 800 |
| 7-8 p.2 ↗ | 1A | Motor variant / winding code |
| 9-10 p.2 ↗ | 31 / 32 / K0 / K1 / K2 | Variant code: 31/32 = VFD type G; K0/K1/K2 = VFD type F |
Ordering Data
| Ordering Code | Part No. | Variant / Code | Applies To | Note |
|---|---|---|---|---|
| 2BH1800-1A316 p.2 ↗ | 2BH1800-1A316 | G | VFD type G, 85 Hz, 370 V | 10.2 kW, -220/180 mbar |
| 2BH1800-1A326 p.2 ↗ | 2BH1800-1A326 | G | VFD type G, 85 Hz, 380 V | 14.0 kW, -380/320 mbar |
| 2BH1800-1AK06 p.2 ↗ | 2BH1800-1AK06 | F | VFD type F, 85 Hz, 400 V | 7.5 kW, -90/80 mbar |
| 2BH1800-1AK16 p.2 ↗ | 2BH1800-1AK16 | F | VFD type F, 85 Hz, 400 V | 10.2 kW, -220/180 mbar |
| 2BH1800-1AK26 p.2 ↗ | 2BH1800-1AK26 | F | VFD type F, 85 Hz, 400 V | 14.0 kW, -380/320 mbar |
Related models
Elmo Rietschle 2BH1009
Elmo Rietschle 2BH1014
Elmo Rietschle 2BH1015
Elmo Rietschle 2BH1023
Elmo Rietschle 2BH1035
Elmo Rietschle 2BH1100
Elmo Rietschle 2BH1200
Elmo Rietschle 2BH1300
Elmo Rietschle 2BH1310
Elmo Rietschle 2BH1330
Elmo Rietschle 2BH1400
Elmo Rietschle 2BH1410
Elmo Rietschle 2BH1430
Elmo Rietschle 2BH1490
Elmo Rietschle 2BH1500
Elmo Rietschle 2BH1510
Elmo Rietschle 2BH1530
Elmo Rietschle 2BH1590
Elmo Rietschle 2BH1600
Elmo Rietschle 2BH1610
Elmo Rietschle 2BH1630
Elmo Rietschle 2BH1640
Elmo Rietschle 2BH1690
Elmo Rietschle 2BH1800
Elmo Rietschle 2BH1810
Elmo Rietschle 2BH1830
Elmo Rietschle 2BH1900
Elmo Rietschle 2BH1910
Elmo Rietschle 2BH1930
Elmo Rietschle 2BH1940
Elmo Rietschle 2BH1943