Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — 2BH1800 IE3 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH1 800-1: side channel blower with IE3-motors, 3~ 50/60 Hz, IP55, insulation class F, UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate E225239). Covers performance sizes 1, 2, 3 and voltage/frequency variants (190-210 V Δ, 220-240 V Δ / 380-420 V Y, 380-420 V Δ / 660-725 V Y, 475-525 V Y, 550-600 V Y, 440-480 V Δ, 460 V Δ, 200 V Y, 230 V Y / 460 V Y).

Technical Data

Parameter Value Condition
Rated voltage 190-210 V p.2 ↗ 2BH1800-1AK01, size 1, 50 Hz, Δ
Rated current 17,1 A p.2 ↗ 2BH1800-1AK01, size 1, 50 Hz, Δ
Motor power 4,6 kW p.2 ↗ 2BH1800-1AK01, size 1, 50 Hz
Max. pressure 210 mbar p.2 ↗ 2BH1800-1AK01, size 1, 50 Hz
Max. vacuum -220 mbar p.2 ↗ 2BH1800-1AK01, size 1, 50 Hz
Sound pressure level 71 dB(A) p.2 ↗ 2BH1800-1AK01, size 1, 50 Hz
Efficiency class IE3 p.2 ↗ 2BH1800-1AK01, size 1, 50 Hz
Weight 113 kg p.2 ↗ 2BH1800-1AK01, size 1, 50 Hz
Rated voltage 190-210 / 380-420 V p.2 ↗ 2BH1800-1AK01, size 1, 60 Hz, Δ/Y
Rated current 19,6 / 9,8 A p.2 ↗ 2BH1800-1AK01, size 1, 60 Hz, Δ/Y
Motor power 5,3 kW p.2 ↗ 2BH1800-1AK01, size 1, 60 Hz
Max. pressure 180 mbar p.2 ↗ 2BH1800-1AK01, size 1, 60 Hz
Max. vacuum -190 mbar p.2 ↗ 2BH1800-1AK01, size 1, 60 Hz
Sound pressure level 73 dB(A) p.2 ↗ 2BH1800-1AK01, size 1, 60 Hz
Rated voltage 190-210 V p.2 ↗ 2BH1800-1AK11, size 2, 50 Hz, Δ
Rated current 23,5 A p.2 ↗ 2BH1800-1AK11, size 2, 50 Hz, Δ
Motor power 6,3 kW p.2 ↗ 2BH1800-1AK11, size 2, 50 Hz
Max. pressure 320 mbar p.2 ↗ 2BH1800-1AK11, size 2, 50 Hz
Max. vacuum -320 mbar p.2 ↗ 2BH1800-1AK11, size 2, 50 Hz
Sound pressure level 72 dB(A) p.2 ↗ 2BH1800-1AK11, size 2, 50 Hz
Weight 124 kg p.2 ↗ 2BH1800-1AK11, size 2, 50 Hz
Rated voltage 190-210 V p.2 ↗ 2BH1800-1AK21, size 3, 50 Hz, Δ
Rated current 30,8 A p.2 ↗ 2BH1800-1AK21, size 3, 50 Hz, Δ
Motor power 8,6 kW p.2 ↗ 2BH1800-1AK21, size 3, 50 Hz
Max. pressure 450 mbar p.2 ↗ 2BH1800-1AK21, size 3, 50 Hz

Operating Limits

  • Max. ambient / suction temperature for stated total pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Protection class: IP55 p.2 ↗
  • Insulation class: F p.2 ↗
  • Max. pressure (size 3, 50 Hz): 450 mbar p.2 ↗
  • Max. vacuum (size 3, 50 Hz): -320 mbar p.2 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH1 Series: side channel blower
5-8 p.2 ↗ 800-1 Size / model designation
field 1 p.2 ↗ 1 Performance size 1, 2 or 3
field 2 p.2 ↗ A Voltage/frequency variant group (A = 50/60 Hz dual voltage, Q = 60 Hz / special voltage)
field 3 p.2 ↗ K Voltage code: K = 190-210 V Δ / 380-420 V Y (50 Hz), 190-210 V Δ / 380-420 V Y (60 Hz); Q = 475-525 V Y (50 Hz), 550-600 V Y (60 Hz)
field 4 p.2 ↗ 0 Fixed digit
field 5 p.2 ↗ 1 Fixed digit
field 6 p.2 ↗ □ Voltage connection / frequency option: 6 = 220-240 V Δ / 380-420 V Y (50 Hz), 440-480 V Y (60 Hz); 7 = 380-420 V Δ / 660-725 V Y (50 Hz), 440-480 V Δ (60 Hz)

Ordering Data

Ordering Code Part No. Variant / Code Applies To Note
2BH1800-1AK01 p.2 ↗ 2BH1800-1AK01 size 1, 50/60 Hz, 190-210 V Δ / 380-420 V Y IE3, 4,6 kW (50 Hz) / 5,3 kW (60 Hz), 113 kg
2BH1800-1AK11 p.2 ↗ 2BH1800-1AK11 size 2, 50/60 Hz, 190-210 V Δ / 380-420 V Y IE3, 6,3 kW (50 Hz) / 7,3 kW (60 Hz), 124 kg
2BH1800-1AK21 p.2 ↗ 2BH1800-1AK21 size 3, 50/60 Hz, 190-210 V Δ / 380-420 V Y IE3, 8,6 kW (50 Hz) / 9,9 kW (60 Hz), 135 kg
2BH1800-1AK06 p.2 ↗ 2BH1800-1AK06 size 1, 50/60 Hz, 220-240 V Δ / 380-420 V Y IE3, 4,6 kW (50 Hz) / 5,3 kW (60 Hz), 113 kg
2BH1800-1AK16 p.2 ↗ 2BH1800-1AK16 size 2, 50/60 Hz, 220-240 V Δ / 380-420 V Y IE3, 6,3 kW (50 Hz) / 7,3 kW (60 Hz), 124 kg
2BH1800-1AK26 p.2 ↗ 2BH1800-1AK26 size 3, 50/60 Hz, 220-240 V Δ / 380-420 V Y IE3, 8,6 kW (50 Hz) / 9,9 kW (60 Hz), 135 kg
2BH1800-1AQ03 p.2 ↗ 2BH1800-1AQ03 size 1, 50/60 Hz, 475-525 V Y / 550-600 V Y IE3, 4,6 kW (50 Hz) / 5,3 kW (60 Hz)
2BH1800-1AQ13 p.2 ↗ 2BH1800-1AQ13 size 2, 50/60 Hz, 475-525 V Y / 550-600 V Y IE3, 6,3 kW (50 Hz) / 7,3 kW (60 Hz)
2BH1800-1AQ23 p.2 ↗ 2BH1800-1AQ23 size 3, 50/60 Hz, 475-525 V Y / 550-600 V Y IE3, 8,6 kW (50 Hz) / 9,9 kW (60 Hz)
2BH1800-1AQ07 p.2 ↗ 2BH1800-1AQ07 size 1, 50/60 Hz, 380-420 V Δ / 660-725 V Y IE3, 4,6 kW (50 Hz) / 5,3 kW (60 Hz), 110 kg