Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — G-BH1 2BH1810 IE3 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH1 810: side channel blower with integrated frequency converter (VFD), type 2BH1810, variants -1H336, -1H346, -1HK26, -1HK36, -1HK46; frequency converter types 2FC4xxx-1□□00 (A–K); accessories (differential pressure transmitters, USB adaptor cable, MMI handheld, INVERTERpc software).

Technical Data

Parameter Value Condition
Rated motor voltage 85 V p.2 ↗ 2BH1810-1H336, 50 Hz
Rated motor current 370 A p.2 ↗ 2BH1810-1H336, 50 Hz
Rated motor power 40,0 kW p.2 ↗ 2BH1810-1H336, 50 Hz
Max. differential pressure (vacuum) -480 mbar p.2 ↗ 2BH1810-1H336, 50 Hz
Max. differential pressure (pressure) 440 mbar p.2 ↗ 2BH1810-1H336, 50 Hz
Sound pressure level 85 dB(A) p.2 ↗ 2BH1810-1H336, 50 Hz
Weight 80/81 kg p.2 ↗ 2BH1810-1H336, 50 Hz
Rated motor current 48,0 A p.2 ↗ 2BH1810-1H346, 50 Hz
Rated motor power 25,0 kW p.2 ↗ 2BH1810-1H346, 50 Hz
Max. differential pressure (pressure) 600 mbar p.2 ↗ 2BH1810-1H346, 50 Hz
Weight 80/81 kg p.2 ↗ 2BH1810-1H346, 50 Hz
Max. differential pressure (vacuum) -460 mbar p.2 ↗ 2BH1810-1HK26, 50 Hz
Max. differential pressure (pressure) 420 mbar p.2 ↗ 2BH1810-1HK26, 50 Hz
Sound pressure level 71 dB(A) p.2 ↗ 2BH1810-1HK26, 50 Hz
Weight 80/81 kg p.2 ↗ 2BH1810-1HK26, 50 Hz
Rated motor voltage 400 V p.2 ↗ 2BH1810-1HK36, 50 Hz
Rated motor current 26,0 A p.2 ↗ 2BH1810-1HK36, 50 Hz
Rated motor power 14,0 kW p.2 ↗ 2BH1810-1HK36, 50 Hz
Max. differential pressure (vacuum) -460 mbar p.2 ↗ 2BH1810-1HK36, 50 Hz
Max. differential pressure (pressure) 670 mbar p.2 ↗ 2BH1810-1HK36, 50 Hz
Rated motor current 39,5 A p.2 ↗ 2BH1810-1HK46, 50 Hz
Rated motor power 20,5 kW p.2 ↗ 2BH1810-1HK46, 50 Hz
Max. differential pressure (pressure) 670 mbar p.2 ↗ 2BH1810-1HK46, 50 Hz
Rated motor current 53,7 A p.2 ↗ 2BH1810, 50 Hz (VFD variant)
Rated motor power 28,2 kW p.2 ↗ 2BH1810, 50 Hz (VFD variant)

Operating Limits

  • Suction and ambient temperature for stated total pressure differences: up to 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Minimum pulse frequency for frequency converter operation: 4 kHz p.1 ↗
  • Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
  • Minimum mains voltage for frequency converters: 380 V p.1 ↗
  • Protection class of frequency converter: IP55 p.2 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH181 Side channel blower series 2BH1, size 810
8-11 p.2 ↗ 1H33 / 1H34 / 1HK2 / 1HK3 / 1HK4 Motor/voltage variant: 1H33 = 85 V, 1H34 = 85 V higher power, 1HK2 = VFD variant, 1HK3 = 400 V, 1HK4 = 400 V higher power
field 1 (VFD type) p.2 ↗ A–K Frequency converter size: A=2FC4152, B=2FC4222, C=2FC4302, D=2FC4402, E=2FC4552, F=2FC4752, G=2FC4113, H=2FC4153, J=2FC4183, K=2FC4223
field 2 (VFD type) p.2 ↗ □ Placeholder in 2FC4xxx-1□□00 order code