Technical Data Sheet — G-BH1 BH1015-2 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet BH1015-2 (2BH1410), G-BH1 side channel blower with 1-phase motor; variants BH1015-2AHA-HV5-BA0 (115/230 V) and BH1015-2AHA-HV4-BA0 (100/200 V), 50 Hz and 60 Hz.

Technical Data

Parameter Value Condition
Rated pressure -112 inch H2O p.2 ↗ BH1015-2, 50 Hz
Max. differential pressure 132 inch H2O p.2 ↗ BH1015-2, 50 Hz
Voltage 115 / 230 V p.2 ↗ BH1015-2AHA-HV5-BA0, 50 Hz
Current 19,0 / 9,5 A p.2 ↗ BH1015-2AHA-HV5-BA0, 50 Hz
Power 2,0 hp p.2 ↗ BH1015-2AHA-HV5-BA0, 50 Hz
Sound pressure level 67 dB(A) p.2 ↗ BH1015-2AHA-HV5-BA0, 50 Hz
Weight 71 lbs p.2 ↗ BH1015-2AHA-HV5-BA0, 50 Hz
Voltage 115 / 230 V p.2 ↗ BH1015-2AHA-HV5-BA0, 60 Hz
Current 20,0 / 10,0 A p.2 ↗ BH1015-2AHA-HV5-BA0, 60 Hz
Power 2,3 hp p.2 ↗ BH1015-2AHA-HV5-BA0, 60 Hz
Rated pressure -112 inch H2O p.2 ↗ BH1015-2AHA-HV5-BA0, 60 Hz
Max. differential pressure 132 inch H2O p.2 ↗ BH1015-2AHA-HV5-BA0, 60 Hz
Sound pressure level 77 dB(A) p.2 ↗ BH1015-2AHA-HV5-BA0, 60 Hz
Weight 77 lbs p.2 ↗ BH1015-2AHA-HV5-BA0, 60 Hz
Protection category IP 55 p.1 ↗ standard motors
Insulation class F p.1 ↗ standard motors

Operating Limits

  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Voltage tolerance, single-phase machines: +/- 5 % p.2 ↗

Type Code Decoder

Position Token Meaning
1-9 p.2 ↗ BH1015-2 Type/size designation (2BH1410)
field 1 p.2 ↗ AHA Motor/design variant
field 2 p.2 ↗ HV4 Voltage variant 100/200 V (50/60 Hz)
field 2 p.2 ↗ HV5 Voltage variant 115/230 V (50/60 Hz)
field 3 p.2 ↗ BA0 Configuration suffix