Technical Data Sheet — G-BH1 BH1015-6 side channel blower (EN)
Technical Reference Summary
Covered Models & Document Scope
Data sheet BH1015-6 (2BH1430), side channel blower with 1-phase motor, 50/60 Hz, IP55, insulation class F, UL/CSA approved. Ordering codes BH1015-6AAA-FV5-BA0 and BH1015-6AAA-FV4-BA0; motor voltage variants V4 (100/200 V) and V5 (115/230 V).
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated voltage | 115 / 230 V p.2 ↗ | BH1015-6, 50 Hz |
| Rated current | 17,0 / 8,0 A p.2 ↗ | BH1015-6, 50 Hz |
| Power | 1,5 hp p.2 ↗ | BH1015-6, 50 Hz |
| Max. differential pressure vacuum | -60 inch H2O p.2 ↗ | BH1015-6, 50 Hz |
| Max. differential pressure pressure | 56 inch H2O p.2 ↗ | BH1015-6, 50 Hz |
| Sound pressure level | 61 dB(A) p.2 ↗ | BH1015-6, 50 Hz |
| Weight approx. | 49 lbs p.2 ↗ | BH1015-6, 50 Hz |
| Rated voltage | 115 / 230 V p.2 ↗ | BH1015-6, 60 Hz |
| Rated current | 16,0 / 8,0 A p.2 ↗ | BH1015-6, 60 Hz |
| Power | 1,7 hp p.2 ↗ | BH1015-6, 60 Hz |
| Max. differential pressure vacuum | -56 inch H2O p.2 ↗ | BH1015-6, 60 Hz |
| Max. differential pressure pressure | 52 inch H2O p.2 ↗ | BH1015-6, 60 Hz |
| Sound pressure level | 64 dB(A) p.2 ↗ | BH1015-6, 60 Hz |
| Weight approx. | 49 lbs p.2 ↗ | BH1015-6, 60 Hz |
| Protection category | IP55 p.1 ↗ | standard motors |
| Insulation class | F p.1 ↗ | standard motors |
Operating Limits
- Protection category: IP55 p.1 ↗
- Insulation class: F p.1 ↗
- Performance curve tolerance: ±10 % p.1 ↗
- Frequency tolerance: ±2 % maximum p.2 ↗
- Single-phase voltage tolerance: ±5 % p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-9 p.2 ↗ | BH1015-6 | Type / size designation (2BH1430) |
| 10-12 p.2 ↗ | AAA | Basic design variant |
| 14-16 p.2 ↗ | FV5 | Motor voltage variant: FV5 = 115/230 V (50/60 Hz); FV4 = 100/200 V (50/60 Hz) |
| 18-20 p.2 ↗ | BA0 | Configuration suffix |
Ordering Data
| Ordering Code | Part No. | Variant / Code | Applies To | Note |
|---|---|---|---|---|
| BH1015-6AAA-FV5-BA0 p.2 ↗ | BH1015-6AAA-FV5-BA0 | V5 | 50/60 Hz, 115/230 V | 1~ 50/60 Hz, IP55, insulation class F, UL, capacitor for continuous operation |
| BH1015-6AAA-FV4-BA0 p.2 ↗ | BH1015-6AAA-FV4-BA0 | V4 | 50/60 Hz, 100/200 V | 1~ 50/60 Hz, IP55, insulation class F, UL, capacitor for continuous operation |
Related models
Elmo Rietschle 2BH1009
Elmo Rietschle 2BH1014
Elmo Rietschle 2BH1015
Elmo Rietschle 2BH1023
Elmo Rietschle 2BH1035
Elmo Rietschle 2BH1100
Elmo Rietschle 2BH1200
Elmo Rietschle 2BH1300
Elmo Rietschle 2BH1310
Elmo Rietschle 2BH1330
Elmo Rietschle 2BH1400
Elmo Rietschle 2BH1410
Elmo Rietschle 2BH1430
Elmo Rietschle 2BH1490
Elmo Rietschle 2BH1500
Elmo Rietschle 2BH1510
Elmo Rietschle 2BH1530
Elmo Rietschle 2BH1590
Elmo Rietschle 2BH1600
Elmo Rietschle 2BH1610
Elmo Rietschle 2BH1630
Elmo Rietschle 2BH1640
Elmo Rietschle 2BH1690
Elmo Rietschle 2BH1800
Elmo Rietschle 2BH1810
Elmo Rietschle 2BH1830
Elmo Rietschle 2BH1900
Elmo Rietschle 2BH1910
Elmo Rietschle 2BH1930
Elmo Rietschle 2BH1940
Elmo Rietschle 2BH1943