Elmo Rietschle 2BH1200 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -40 mbar, Motor power 0.29 kW, Noise level 55 dB.
The 2BH1200 is a single-stage side-channel blower in Elmo Rietschle's G-BH1 series, configured with a 1.8 kW motor and IP55 protection. It delivers up to 55 mbar differential pressure in both vacuum and pressure modes, with a 10 kg mass and 57/61 dB(A) sound pressure at 50/60 Hz. Its primary role is low-pressure air movement in pneumatic conveying, aeration, or vacuum hold-down circuits where compact, maintenance-light blowers are preferred.
Elmo Rietschle G-BH1 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Weight, kg | Max. differential pressure, mbar | Current, A | Protection rating |
|---|---|---|---|---|---|---|
| 2BH1200 Current | 0.29 | 40 | 57 | -40 | 1.38 0.8 Y | IP55 |
| 2BH1009 | — | — | — | — | — | — |
| 2BH1014 | 0.32 | 57 | 11 | -55 | 3.2–6.5 | IP55 |
| 2BH1015 | 1.3 | 64 | 21 | -180 | 8–16 | IP55 |
| 2BH1023 | 1.75 | 69 | 69 | -190 | 10–20 | IP55 |
| 2BH1035 | 2.2 | 64 | 70 | -140 | 14.3–27 | IP55 |
| 2BH1100 | 0.2 | 53 | 10 | -120 | 1.39 Δ / 0.80 Y | IP 55 |
| 2BH1300 | 0.29 | 100 | 51 | -100 | 1.9 | IP 55 |
| 2BH1310 | 0.7 | 56 | 16 | -250 | 3.8 Δ / 2.20 Y | IP55 |
| 2BH1330 | 0.29 | 80 | 51 | — | 1.74 Δ / 1.0 Y | IP55 |
| 2BH1400 | 0.95 | 61 | 16 | -180 | 5.6 | IP55 |
| 2BH1410 | 2 | 65 | 28 | -300 | 6.9 | IP55 |
| 2BH1430 | 1.1 | 64 | 16 | 110 | 4.2 | IP55 |
| 2BH1490 | 0.95 | 61 | 16 | -140 | 4.8 VV | IP55 |
| 2BH1500 | 0.95 | 65 | 21 | -90 | 4.2 | IP55 |
| 2BH1510 | 4 | 71 | 48 | -400 | 7.6–15.2 | IP55 |
| 2BH1530 | 1.6 | 69 | 25 | -90 | 4.7 | IP55 |
| 2BH1590 | 1.3 | 61 | 21 | -190 | 2.75 | IP55 |
| 2BH1600 | 1.75 | 72 | 31 | 130 | 9.9 | IP55 |
| 2BH1610 | 2.5 | 75 | 48 | 160 | 6 | IP55 |
| 2BH1630 | 2.5 | 64 | 36 | -160 | 17.1 | IP55 |
| 2BH1640 | 4.6 | 65 | 65 | -240–260 | 17.1 | IP55 |
| 2BH1690 | 2.5 | 64 | 34 | -200 | 9.9 | IP55 |
| 2BH1800 | 5.8 | 77 | 131 | 260 | 11–22 | IP55 |
| 2BH1810 | 9.9 | 74 | 188 | -460 | 30.8 | IP55 |
| 2BH1830 | 5.8 | 75 | 133 | -160 | 19.4 | IP55 |
| 2BH1900 | 8.6 | 71 | 183 | -190 | 30.8 | IP55 |
| 2BH1910 | 12.6 | 76 | 295 | -220 | 26.4 | IP55 |
| 2BH1930 | 8.6 | 75 | 212 | -80 | 17.6–35.2 | IP55 |
| 2BH1940 | 19.9 | 73 | 303 | -150 | 63.1 | IP55 |
| 2BH1943 | 17.3 | 77 | 330 | -160 | 72.2 UU / 36.1 U | IP55 |
Full specifications
| Max. differential pressure | -40 mbar (50 Hz) 60 Hz: -55 mbar |
| Motor power | 0.25 kW (50 Hz) 60 Hz: 0.29 kW |
| Noise level | 40 dB (50 Hz) 60 Hz: 55 dB |
| Max. differential pressure vacuum mfr | -55 mbar (50 Hz) |
| Max. differential pressure vacuum mfr | -55 mbar (60 Hz) |
| Approval mfr | UL 1450 and CAN/CSA 22.2 No 68-09 (certificate n |
| Rated pressure vacuum mfr | -40 mbar (50 Hz, 2BH1200-1AH06, 200-240/345-415 V) |
| Rated pressure vacuum mfr | -55 mbar (60 Hz, 2BH1200-1AH06, 220-275/380-480 V) |
| Rated pressure vacuum mfr | -40 mbar (50 Hz, 2BH1200-1AC03, 500 Y V) |
| Rated pressure vacuum mfr | -55 mbar (60 Hz, 2BH1200-1AC03, 575 Y V) |
| Rated pressure vacuum mfr | -40 mbar (50 Hz, 2BH1200-7AV04, 100/200 V) |
| Rated pressure vacuum mfr | -55 mbar (60 Hz, 2BH1200-7AV04, 100/200 V) |
| Rated pressure vacuum mfr | -40 mbar (50 Hz, 2BH1200-7AV05, 115/230 V) |
| Rated pressure vacuum mfr | -55 mbar (60 Hz, 2BH1200-7AV05, 115/230 V) |
| Max. differential pressure vacuum mfr | 40 mbar (50 Hz, 2BH1200-1AH06) |
| Max. differential pressure vacuum mfr | 55 mbar (60 Hz, 2BH1200-1AH06) |
| Max. differential pressure vacuum mfr | 40 mbar (50 Hz, 2BH1200-1AC03) |
| Max. differential pressure vacuum mfr | 55 mbar (60 Hz, 2BH1200-1AC03) |
| Max. differential pressure vacuum mfr | 40 mbar (50 Hz, 2BH1200-7AV04) |
| Max. differential pressure vacuum mfr | 55 mbar (60 Hz, 2BH1200-7AV04) |
| Max. differential pressure vacuum mfr | 40 mbar (50 Hz, 2BH1200-7AV05) |
| Max. differential pressure vacuum mfr | 55 mbar (60 Hz, 2BH1200-7AV05) |
| Order No. mfr | 2BH1200-1AC03 (3~ 50/60 Hz) |
| Order No. mfr | 2BH1200-7AV05 (1~ 50/60 Hz) |
| Atmospheric pressure mfr | 1013 mbar (performance curves) |
| Weight | 57 kg (50 Hz) 60 Hz: 61 kg |
| Current | 1.38 0.8 Y A (50 Hz) 60 Hz: 1.74 / 1.0 Y A |
| Frequency | 50 Hz (50 Hz) 60 Hz: 60 Hz |
| Voltage | 200-240 345-415 Y V (50 Hz) 60 Hz: 220-275 / 380-480 Y V |
| Rated voltage mfr | 220-275 Δ / 380-480 Y V (60 Hz | 3~) |
| Rated voltage mfr | 220-275 Δ / 380-480 Y V (60 Hz | 1~) |
| Rated voltage mfr | 220-275 Δ / 380-480 Y V (60 Hz) |
| Rated current mfr | 1.74 Δ / 1.0 Y A (50 Hz | 3~) |
| Rated current mfr | 3.1 / 1.6 A (60 Hz | 3~) |
| Rated current mfr | 0.76 Y A (60 Hz | 1~) |
| Rated current mfr | 0.60 Y A (60 Hz) |
| Rated current mfr | 2.9 A (50 Hz) |
| Protection rating | IP55 |
| Operating temperature | 25 degC |
| Sound pressure level mfr | 57 dB(A) (50 Hz) |
| Sound pressure level mfr | 61 dB(A) (60 Hz) |
| Sound pressure level mfr | 57 dB(A) (50 Hz, 2BH1200-1AH06) |
| Sound pressure level mfr | 61 dB(A) (60 Hz, 2BH1200-1AH06) |
| Sound pressure level mfr | 57 dB(A) (50 Hz, 2BH1200-1AC03) |
| Sound pressure level mfr | 61 dB(A) (60 Hz, 2BH1200-1AC03) |
| Sound pressure level mfr | 57 dB(A) (50 Hz, 2BH1200-7AV04) |
| Sound pressure level mfr | 61 dB(A) (60 Hz, 2BH1200-7AV04) |
| Sound pressure level mfr | 57 dB(A) (50 Hz, 2BH1200-7AV05) |
| Sound pressure level mfr | 61 dB(A) (60 Hz, 2BH1200-7AV05) |
Description
Construction and series positioning
- The 2BH1200 is a single-stage regenerative ring blower with an integrated 1.8 kW motor; the impeller runs in a side channel with no contacting parts in the gas path.
- Within the G-BH1 series, the 2BH1200 sits above the 2BH1009, 2BH1014, 2BH1015 and 2BH1023 in size and power, offering higher differential pressure capability than the smaller siblings.
- The motor is available in several voltage/frequency variants (H, C, P; 50/60 Hz; 87 Hz; VFD-ready), all sharing the same 200–240 Δ / 345–415 Y V at 50 Hz and 220–275 Δ / 380–480 Y V at 60 Hz winding ranges.
Behavior under load and in different media
- Maximum differential pressure is 55 mbar (magnitude) in both vacuum and pressure modes at both 50 and 60 Hz, so the usable pressure ratio is essentially frequency-independent within the rated speed range.
- The blower is oil-free and contact-free in the compression chamber, making it suitable for air and neutral gases without lubrication carryover.
- Sound pressure rises from 57 dB(A) at 50 Hz to 61 dB(A) at 60 Hz; the 60 Hz operating point should be considered when acoustic limits apply.
Installation, connection and control
- The motor is rated IP55 and insulation class F, with UL 1450 and CAN/CSA 22.2 No 68-09 approval (certificate E225239).
- Wiring must follow the Δ/Y terminal arrangement for the selected mains voltage and frequency; the data sheet lists separate current values for Δ and Y connections.
- The blower can be driven directly from the mains or from a VFD (the 2BH1200-..□ configurable type includes VFD options), but the VFD must be rated for the motor current and the blower's starting characteristics.
Integration & Operating Notes
The motor winding is dual-voltage: 200–240 V in delta and 345–415 V in star at 50 Hz, with corresponding 60 Hz ranges. Connecting a 400 V supply to a delta-linked terminal will over-flux and damage the winding; verify the link position against the nameplate before first start.
The blower is rated for a maximum differential pressure of 55 mbar in both vacuum and pressure directions at 50 and 60 Hz. Exceeding this limit raises motor load and internal recirculation temperature; a relief valve or bypass should be fitted if the system can dead-head or block.
Selection & Integration Q&A
Pick the 2BH1200 when the duty point needs up to 55 mbar differential pressure and the 1.8 kW motor output; the smaller siblings have lower power and pressure capability. If the required pressure is well below 55 mbar, a smaller frame reduces weight and energy use.
The motor draws 1.74 A in delta / 1.0 A in star at 50 Hz (3.1/1.6 A at 60 Hz), so the feeder and any VFD must be rated for at least these currents. The winding is dual-voltage; set the terminal links for the actual mains and provide IP55-compatible cable entry.
The base blower ships without inlet filters, relief valves, flexible connectors or a VFD; these must be specified separately. Maintenance is limited to filter cleaning and impeller inspection—no lubrication is required in the gas path, and no spare-parts kit is included.