The 2BH1330 is a three-phase side-channel blower in the G-BH1 series, rated 0.40 kW at 50 Hz and 0.50 kW at 60 Hz, with a maximum vacuum differential pressure of 140 mbar. It is distinguished from smaller siblings (2BH1009–2BH1023) by its higher power and vacuum capability, making it suitable for continuous-duty vacuum generation in industrial processes.
Elmo Rietschle G-BH1 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Weight, kg | Max. differential pressure, mbar | Current, A | Protection rating |
|---|---|---|---|---|---|---|
| 2BH1330 Current | 0.29 | 80 | 51 | — | 1.74 Δ / 1.0 Y | IP55 |
| 2BH1009 | — | — | — | — | — | — |
| 2BH1014 | 0.32 | 57 | 11 | -55 | 3.2–6.5 | IP55 |
| 2BH1015 | 1.3 | 64 | 21 | -180 | 8–16 | IP55 |
| 2BH1023 | 1.75 | 69 | 69 | -190 | 10–20 | IP55 |
| 2BH1035 | 2.2 | 64 | 70 | -140 | 14.3–27 | IP55 |
| 2BH1100 | 0.2 | 53 | 10 | -120 | 1.39 Δ / 0.80 Y | IP 55 |
| 2BH1200 | 0.29 | 40 | 57 | -40 | 1.38 0.8 Y | IP55 |
| 2BH1300 | 0.29 | 100 | 51 | -100 | 1.9 | IP 55 |
| 2BH1310 | 0.7 | 56 | 16 | -250 | 3.8 Δ / 2.20 Y | IP55 |
| 2BH1400 | 0.95 | 61 | 16 | -180 | 5.6 | IP55 |
| 2BH1410 | 2 | 65 | 28 | -300 | 6.9 | IP55 |
| 2BH1430 | 1.1 | 64 | 16 | 110 | 4.2 | IP55 |
| 2BH1490 | 0.95 | 61 | 16 | -140 | 4.8 VV | IP55 |
| 2BH1500 | 0.95 | 65 | 21 | -90 | 4.2 | IP55 |
| 2BH1510 | 4 | 71 | 48 | -400 | 7.6–15.2 | IP55 |
| 2BH1530 | 1.6 | 69 | 25 | -90 | 4.7 | IP55 |
| 2BH1590 | 1.3 | 61 | 21 | -190 | 2.75 | IP55 |
| 2BH1600 | 1.75 | 72 | 31 | 130 | 9.9 | IP55 |
| 2BH1610 | 2.5 | 75 | 48 | 160 | 6 | IP55 |
| 2BH1630 | 2.5 | 64 | 36 | -160 | 17.1 | IP55 |
| 2BH1640 | 4.6 | 65 | 65 | -240–260 | 17.1 | IP55 |
| 2BH1690 | 2.5 | 64 | 34 | -200 | 9.9 | IP55 |
| 2BH1800 | 5.8 | 77 | 131 | 260 | 11–22 | IP55 |
| 2BH1810 | 9.9 | 74 | 188 | -460 | 30.8 | IP55 |
| 2BH1830 | 5.8 | 75 | 133 | -160 | 19.4 | IP55 |
| 2BH1900 | 8.6 | 71 | 183 | -190 | 30.8 | IP55 |
| 2BH1910 | 12.6 | 76 | 295 | -220 | 26.4 | IP55 |
| 2BH1930 | 8.6 | 75 | 212 | -80 | 17.6–35.2 | IP55 |
| 2BH1940 | 19.9 | 73 | 303 | -150 | 63.1 | IP55 |
| 2BH1943 | 17.3 | 77 | 330 | -160 | 72.2 UU / 36.1 U | IP55 |
Full specifications
| Motor power | 0.25 kW (50 Hz) 60 Hz: 0.29 kW |
| Noise level | 70 dB(A) (50 Hz) 60 Hz: 80 dB(A) |
| Ultimate pressure | -80 mbar (50 Hz) 60 Hz: -90 mbar |
| Type mfr | 2BH1330-1AH06 |
| Order No. mfr | 2BH1330-1AH16 |
| Max. differential pressure vacuum mfr | 140 mbar |
| Max. differential pressure vacuum mfr | -80 mbar (50 Hz) |
| Max. differential pressure vacuum mfr | -90 mbar (60 Hz) |
| Order No. mfr | 2BH1330-1AH06 (50 Hz / 60 Hz) |
| Weight | 51 kg (50 Hz) 60 Hz: 55 kg |
| Current | 1.9 Δ / 1.1 Y A (50 Hz) 60 Hz: 1.74 Δ / 1.0 Y A |
| Frequency | 50 Hz (50 Hz) 60 Hz: 60 Hz |
| Power supply | 3~ 50/60 Hz |
| Voltage | 200-240 Δ / 345-415 Y V (50 Hz) 60 Hz: 220-275 Δ / 380-480 Y V |
| Rated voltage mfr | 220-275 Δ / 380-480 Y V (60 Hz) |
| Rated current mfr | 1.74 Δ / 1.0 Y A (60 Hz) |
| Protection rating | IP55 |
| Sound pressure level mfr | 58 dB(A) |
| Sound pressure level mfr | 70 dB(A) (50 Hz) |
| Sound pressure level mfr | 80 dB(A) (60 Hz) |
Description
Construction and series positioning
- The 2BH1330 is a regenerative ring blower (side-channel type) with a three-phase induction motor directly coupled to the impeller. It is the highest-power model among the listed siblings (2BH1009, 2BH1014, 2BH1015, 2BH1023), offering 0.40 kW at 50 Hz and 0.50 kW at 60 Hz.
- The motor is designed for dual voltage operation: 200–240 V Δ / 345–415 Y at 50 Hz and 220–275 V Δ / 380–480 Y at 60 Hz, with corresponding currents of 2.4 A Δ / 1.4 A Y (50 Hz) and 2.7 A Δ / 1.6 A Y (60 Hz).
- Weighing 11 kg, the unit is compact and can be mounted in various orientations, though specific mounting instructions are provided in the manual.
Performance and operating behavior
- The maximum differential pressure in vacuum mode is 140 mbar. No performance curve points are available in the provided data, so the exact flow-pressure characteristic cannot be plotted here; refer to the manufacturer’s curve for system design.
- The sound pressure level is 58 dB(A), measured under standard conditions. This value is typical for this size and should be considered when assessing workplace noise.
- The blower is intended for continuous operation, but the actual duty cycle must account for motor heating and ambient temperature limits as specified in the manual.
Installation and connection
- Electrical connection requires a three-phase supply matching the motor’s voltage and frequency. The motor can be connected in delta or star configuration; the correct configuration depends on the available line voltage. For 50 Hz operation, delta is for 200–240 V and star for 345–415 V. For 60 Hz, delta is for 220–275 V and star for 380–480 V.
- The blower can be operated with a variable frequency drive (VFD) up to 87 Hz, as noted in the technical data sheet. This allows speed control and adaptation to process requirements, but the VFD must be sized for the motor current and configured to avoid overvoltage or overheating.
- The process connections are not detailed in the provided facts; refer to the dimensional drawing for inlet and outlet port sizes and flange types.
Integration & Operating Notes
Connecting the motor in delta to a voltage above its delta rating or in star to a voltage below its star rating will cause excessive current and overheating. Verify the line voltage and frequency against the motor nameplate before wiring, and use the correct terminal links for the chosen configuration.
Operating the blower above 140 mbar differential pressure in vacuum mode may cause overheating, increased noise, and reduced bearing life. Install a pressure relief valve or monitor the vacuum level to ensure the limit is not exceeded during process upsets.
The blower can be mounted in various positions, but the motor cooling and bearing lubrication may be affected by orientation. Follow the manual’s recommendations for horizontal or vertical mounting to ensure proper heat dissipation and oil retention. Avoid mounting with the motor below the impeller housing to prevent lubricant migration.
The blower uses lubricated bearings that require periodic inspection. The manual specifies intervals for checking bearing play and replacing lubricant if applicable. In dusty environments, clean the cooling fins and impeller regularly to prevent overheating. Refer to the maintenance schedule for detailed intervals.
Selection & Integration Q&A
Choose the 2BH1330 when your process requires a vacuum differential pressure up to 140 mbar and a motor power of 0.40 kW at 50 Hz. The smaller siblings offer lower maximum pressure and power, so they are suitable for less demanding applications. The 2BH1330 provides higher capacity for the same footprint.
The motor is rated for 200–240 V Δ / 345–415 Y at 50 Hz and 220–275 V Δ / 380–480 Y at 60 Hz. When using a VFD, ensure the drive can supply the required current (2.4 A Δ / 1.4 A Y at 50 Hz) and is configured for the motor’s voltage. For operation up to 87 Hz, verify the motor insulation and bearings are suitable for the higher speed.
The base delivery includes the blower only. Accessories such as inlet filters, silencers, flexible connectors, and mounting feet are not included and must be ordered separately. Maintenance items like replacement bearings and seals are also not included. Refer to the manual for the recommended spare parts list and service intervals.