Elmo Rietschle 2BH1530
Elmo Rietschle 2BH1530 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -90 mbar, Motor power 1.3 kW, Noise level 60 dB.
The 2BH1530 is a side-channel blower from the G-BH1 series, driven by an IE3 efficiency-class motor and configured for 380–420 V Δ / 660–725 Y at 50 Hz or 460 V Δ at 60 Hz. It delivers 250 m³/h suction capacity at -220 mbar (50 Hz) and -260 mbar (60 Hz), with a maximum differential pressure of 250 mbar in pressure mode. This modification is the higher-capacity unit within the 2BH10xx sibling group, intended for continuous vacuum or pressure duty in industrial processes requiring oil-free, contactless gas handling.
Elmo Rietschle G-BH1 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Weight, kg | Max. differential pressure, mbar | Current, A | Protection rating |
|---|---|---|---|---|---|---|
| 2BH1530 Current | 1.6 | 69 | 25 | -90 | 4.7 | IP55 |
| 2BH1009 | — | — | — | — | — | — |
| 2BH1014 | 0.32 | 57 | 11 | -55 | 3.2–6.5 | IP55 |
| 2BH1015 | 1.3 | 64 | 21 | -180 | 8–16 | IP55 |
| 2BH1023 | 1.75 | 69 | 69 | -190 | 10–20 | IP55 |
| 2BH1035 | 2.2 | 64 | 70 | -140 | 14.3–27 | IP55 |
| 2BH1100 | 0.2 | 53 | 10 | -120 | 1.39 Δ / 0.80 Y | IP 55 |
| 2BH1200 | 0.29 | 40 | 57 | -40 | 1.38 0.8 Y | IP55 |
| 2BH1300 | 0.29 | 100 | 51 | -100 | 1.9 | IP 55 |
| 2BH1310 | 0.7 | 56 | 16 | -250 | 3.8 Δ / 2.20 Y | IP55 |
| 2BH1330 | 0.29 | 80 | 51 | — | 1.74 Δ / 1.0 Y | IP55 |
| 2BH1400 | 0.95 | 61 | 16 | -180 | 5.6 | IP55 |
| 2BH1410 | 2 | 65 | 28 | -300 | 6.9 | IP55 |
| 2BH1430 | 1.1 | 64 | 16 | 110 | 4.2 | IP55 |
| 2BH1490 | 0.95 | 61 | 16 | -140 | 4.8 VV | IP55 |
| 2BH1500 | 0.95 | 65 | 21 | -90 | 4.2 | IP55 |
| 2BH1510 | 4 | 71 | 48 | -400 | 7.6–15.2 | IP55 |
| 2BH1590 | 1.3 | 61 | 21 | -190 | 2.75 | IP55 |
| 2BH1600 | 1.75 | 72 | 31 | 130 | 9.9 | IP55 |
| 2BH1610 | 2.5 | 75 | 48 | 160 | 6 | IP55 |
| 2BH1630 | 2.5 | 64 | 36 | -160 | 17.1 | IP55 |
| 2BH1640 | 4.6 | 65 | 65 | -240–260 | 17.1 | IP55 |
| 2BH1690 | 2.5 | 64 | 34 | -200 | 9.9 | IP55 |
| 2BH1800 | 5.8 | 77 | 131 | 260 | 11–22 | IP55 |
| 2BH1810 | 9.9 | 74 | 188 | -460 | 30.8 | IP55 |
| 2BH1830 | 5.8 | 75 | 133 | -160 | 19.4 | IP55 |
| 2BH1900 | 8.6 | 71 | 183 | -190 | 30.8 | IP55 |
| 2BH1910 | 12.6 | 76 | 295 | -220 | 26.4 | IP55 |
| 2BH1930 | 8.6 | 75 | 212 | -80 | 17.6–35.2 | IP55 |
| 2BH1940 | 19.9 | 73 | 303 | -150 | 63.1 | IP55 |
| 2BH1943 | 17.3 | 77 | 330 | -160 | 72.2 UU / 36.1 U | IP55 |
Full specifications
| Max. differential pressure | -120 mbar (50 Hz) 60 Hz: -90 mbar |
| Motor power | 1.30 kW (50 Hz) 60 Hz: 1.60 kW |
| Noise level | 60 dB (50 Hz) 60 Hz: 69 dB |
| Suction capacity mfr | 250 m3/h (50 Hz, vacuum -220 mbar) |
| Suction capacity mfr | 250 m3/h (60 Hz, vacuum -260 mbar) |
| Vacuum mfr | -120 mbar (50 Hz) |
| Order No. mfr | 2BH1530-0AK11 (50 Hz) |
| Vacuum mfr | -90 mbar (60 Hz) |
| Order No. mfr | 2BH1530-0AK11 (60 Hz) |
| Vacuum mfr | -90 mbar (60 Hz NP) |
| Max. differential pressure (vacuum) (alt 50 Hz) mfr | -220 mbar (50 Hz) |
| Max. differential pressure (vacuum) (alt 60 Hz) mfr | -260 mbar (60 Hz) |
| Max. differential pressure (pressure) (alt 50 Hz) mfr | 250 mbar (50 Hz) |
| Max. differential pressure (pressure) (alt 60 Hz) mfr | 250 mbar (60 Hz) |
| Stages (alt var) mfr | 3 |
| Weight | 25 kg |
| Number of stages | 1 |
| Weight approx. mfr | 31 kg |
| Weight approx. (alt var) mfr | 31 kg |
| Current | 4.7 A (50 Hz) 60 Hz: 6.3 / 3.2 A |
| Frequency | 50/60 Hz |
| Power supply | 3~ 50/60 Hz |
| Voltage | 190-210 V (50 Hz) 60 Hz: 190-210 / 380-420 V |
| Power consumption at pump shaft mfr | 2.50 kW (50 Hz, -220 mbar) |
| Power consumption at pump shaft mfr | 3.00 kW (60 Hz, -260 mbar) |
| Efficiency class mfr | IE3 |
| Efficiency class mfr | IE3 (50 Hz) |
| Efficiency class mfr | IE3 (60 Hz) |
| Efficiency class mfr | NP (60 Hz NP) |
| Power (alt 50 Hz) mfr | 2.50 kW (50 Hz) |
| Voltage (alt 50 Hz) mfr | 380-420 / 660-725 V (50 Hz) |
| Voltage (alt 60 Hz) mfr | 440-480 V (60 Hz) |
| Current (alt 50 Hz) mfr | 8.8 / 5.1 A (50 Hz) |
| Current (alt 60 Hz) mfr | 5.2 A (60 Hz) |
| Protection rating | IP55 |
| Sound pressure level mfr | 60 dB(A) (50 Hz) |
| Sound pressure level mfr | 69 dB(A) (60 Hz) |
| Sound pressure level mfr | 69 dB(A) (60 Hz NP) |
| Sound pressure level (alt 50 Hz) mfr | 69 dB (50 Hz) |
| Sound pressure level (alt 60 Hz) mfr | 70 dB (60 Hz) |
Description
Construction and series positioning
- The 2BH1530 is a regenerative (side-channel) blower with a dynamically balanced impeller running without contact or wear rings, driven directly by an IE3-class induction motor.
- The motor is wound for dual voltage: 380–420 V Δ / 660–725 Y at 50 Hz and 460 V Δ at 60 Hz, with corresponding currents of 5.0 A Δ / 2.9 A Y and 5.2 A Δ.
Behavior under load and media
- At 50 Hz the unit moves 250 m³/h at -220 mbar vacuum, drawing 2.50 kW at the pump shaft; at 60 Hz the same 250 m³/h is delivered at -260 mbar, with shaft power rising to 3.00 kW.
- The maximum vacuum level is -260 mbar at 60 Hz; the maximum pressure-mode differential is 250 mbar at 60 Hz. These define the usable operating envelope.
- Sound pressure level is 60 dB(A) at 50 Hz and 69 dB(A) at 60 Hz, and the motor is rated IP55 with class F insulation for dusty or mildly wet industrial environments.
Installation and operation
- The blower is a direct-drive, foot-mounted unit; the IE3 motor requires a suitable starter or variable-frequency drive rated for the motor nameplate power and current (e.g., 5.0 A Δ / 2.9 A Y at 50 Hz, 5.2 A Δ at 60 Hz).
- No digitized performance curves or application-specific certificates are supplied in the verified data; selection should rely on the tabulated suction capacity and differential pressure points.
- The data sheet covers multiple voltage and order-number variants (e.g., -0AQ37 for the 380–420/660–725 V winding); confirm the exact order code against the required supply before installation.
Integration & Operating Notes
The maximum vacuum level is -260 mbar at 60 Hz; the maximum pressure-mode differential is 250 mbar at 60 Hz. Operating beyond these limits increases shaft power above the 3.00 kW rating and can overheat the motor or overload the impeller. Install a relief valve or pressure switch to keep the process within the envelope.
The motor draws 5.0 A Δ / 2.9 A Y at 50 Hz and 5.2 A Δ at 60 Hz. A thermal overload relay or drive overload parameter must be set to the motor nameplate full-load current for the actual connection (delta or star) so that a blocked filter, closed valve, or impeller fouling trips the unit before the winding exceeds class F temperature limits.
Because the side-channel impeller runs contactless, wear is minimal, but dust ingress through the IP55 motor is not the only concern: the process gas path must be kept free of particles that can erode the impeller. Schedule periodic inspection of any inlet filter and check for unusual noise or current rise, which indicate fouling or bearing wear.
Selection & Integration Q&A
Pick the 2BH1530 when your process needs around 250 m³/h at -220 to -260 mbar and up to 2.5–3.0 kW shaft power. The 2BH10xx siblings are smaller-frame units; choose them only if your required flow and differential pressure fall within their lower capacity, avoiding unnecessary energy use.
Use a starter or VFD rated for the motor nameplate power and current (e.g., 5.0 A Δ / 2.9 A Y at 50 Hz, 5.2 A Δ at 60 Hz), set to the motor's nameplate current. Connect the 2BH1530-0AQ37 winding in delta for 380–420 V at 50 Hz or 460 V at 60 Hz, or in star for 660–725 V at 50 Hz. Confirm the order code matches your site voltage before wiring.
The base delivery is the blower only; inlet filters, silencers, flexible connectors, relief valves, and a starter or VFD are not included and must be specified separately. No spare parts kit is listed in the verified data. Plan periodic inspection of the process gas path and motor bearings, and verify the order code for voltage variant before commissioning.