Elmo Rietschle 2BH1630
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH1630

Elmo Rietschle 2BH1630 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -300 mbar, Motor power 2.5 kW, Noise level 64 dB.

The 2BH1630 is a side-channel regenerative blower in the G-BH1 series, driven by a 3.0 kW IE3 motor rated for 50/60 Hz operation. It delivers up to -140 mbar vacuum or 120 mbar positive pressure, distinguishing it from smaller siblings like the 2BH1009 and 2BH1014 by its higher power and flow capacity. It is intended for continuous-duty vacuum or pressure generation in industrial processes requiring oil-free, contactless compression.

Max. differential pressure
-300 mbar
Motor power
2.5 kW
Noise level
64 dB
Weight
52 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1630 Current 2.56436-16017.1IP55
2BH1009 ——————
2BH1014 0.325711-553.2–6.5IP55
2BH1015 1.36421-1808–16IP55
2BH1023 1.756969-19010–20IP55
2BH1035 2.26470-14014.3–27IP55
2BH1100 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1300 0.2910051-1001.9IP 55
2BH1310 0.75616-2503.8 Δ / 2.20 YIP55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1400 0.956116-1805.6IP55
2BH1410 26528-3006.9IP55
2BH1430 1.164161104.2IP55
2BH1490 0.956116-1404.8 VVIP55
2BH1500 0.956521-904.2IP55
2BH1510 47148-4007.6–15.2IP55
2BH1530 1.66925-904.7IP55
2BH1590 1.36121-1902.75IP55
2BH1600 1.7572311309.9IP55
2BH1610 2.575481606IP55
2BH1640 4.66565-240–26017.1IP55
2BH1690 2.56434-2009.9IP55
2BH1800 5.87713126011–22IP55
2BH1810 9.974188-46030.8IP55
2BH1830 5.875133-16019.4IP55
2BH1900 8.671183-19030.8IP55
2BH1910 12.676295-22026.4IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1940 19.973303-15063.1IP55
2BH1943 17.377330-16072.2 UU / 36.1 UIP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -160 mbar (50 Hz, order no. 2BH1630-0AK11)
60 Hz, order no. 2BH1630-0AK11: -140 mbar · 50 Hz, order no. 2BH1630-0AK21: -240 mbar · 60 Hz, order no. 2BH1630-0AK21: -230 mbar · 50 Hz, order no. 2BH1630-1AK31: -260 mbar · 60 Hz, order no. 2BH1630-1AK31: -300 mbar
Motor power 2.50 kW (50 Hz, order no. 2BH1630-0AK11)
60 Hz, order no. 2BH1630-0AK11: 3.00 kW · 50 Hz, order no. 2BH1630-0AK21: 3.45 kW · 60 Hz, order no. 2BH1630-0AK21: 4.0 kW · 50 Hz, order no. 2BH1630-1AK31: 4.6 kW · 60 Hz, order no. 2BH1630-1AK31: 5.3 kW
Noise level 64 dB (50 Hz)
60 Hz: 70 dB · 50 Hz, 2-stage: 71 dB · 60 Hz, 2-stage: 74 dB · 50 Hz, 3-stage: 69 dB · 60 Hz, 3-stage: 71 dB
Max. differential pressure vacuum mfr -140 mbar (50 Hz)
Max. differential pressure vacuum mfr -140 mbar (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 36 kg (1-stage)
2-stage: 40 kg · 3-stage: 52 kg
Number of stages 1 (order no. 2BH1630-0AK11)
order no. 2BH1630-0AK21: 2 · order no. 2BH1630-1AK31: 3
Electrical, Power & Drive Specifications
Current 9.9 A (50 Hz, order no. 2BH1630-0AK11)
60 Hz, order no. 2BH1630-0AK11: 12.0 / 6.0 A · 50 Hz, order no. 2BH1630-0AK21: 13.3 A · 60 Hz, order no. 2BH1630-0AK21: 15.2 / 7.6 A · 50 Hz, order no. 2BH1630-1AK31: 17.1 A · 60 Hz, order no. 2BH1630-1AK31: 19.6 / 9.8 A
Frequency 50 Hz
Power supply 3~ 50/60 Hz
Voltage 190-210 Δ V (50 Hz, order no. 2BH1630-0AK11)
60 Hz, order no. 2BH1630-0AK11: 190-210 YY / 380-420 Y V · 50 Hz, order no. 2BH1630-0AK16: 220-240 Δ / 380-420 Y V · 60 Hz, order no. 2BH1630-0AK16: 220-240 YY / 440-480 Y V
Efficiency class mfr IE3
Frequency (alt var) mfr 60 Hz
Operating Conditions, Environment & Protection
Protection rating IP55
Sound pressure level mfr 64 dB(A) (50 Hz)
Sound pressure level mfr 70 dB(A) (60 Hz)

Description

Construction and series positioning

The 2BH1630 is a single-stage side-channel blower with an impeller directly mounted on the motor shaft. The motor is a 3.0 kW IE3 efficiency class unit, available for 380–420 V at 50 Hz or 200 V at 60 Hz, with IP55 protection and class F insulation. Weighing approximately 36 kg, it is the largest among the listed G-BH1 siblings (2BH1009, 2BH1014, 2BH1015, 2BH1023), which are lower-power variants. The 2BH1630 is chosen when higher pressure or vacuum levels are needed than those smaller models can provide.

Performance and operating envelope

Maximum differential pressure is -140 mbar in vacuum mode and 120 mbar in pressure mode, identical at both 50 and 60 Hz. Sound pressure level is 64 dB(A) at 50 Hz and 70 dB(A) at 60 Hz. The blower is oil-free and contactless, with no internal lubrication or wear parts in the compression chamber. It can operate continuously in either vacuum or pressure mode, but the maximum differential pressure must not be exceeded to avoid motor overload.

Installation and connection

No PDF digests were provided, so specific installation details are not available. Generally, side-channel blowers require rigid mounting, free air intake and exhaust, and protection from ingress of foreign matter. Electrical connection must match the nameplate voltage and frequency; the motor is not dual-voltage without reconnection. Ensure the supply can handle the starting current and that the IP55 enclosure is not compromised during wiring.

Integration & Operating Notes

Electrical
Motor is not dual-voltage without reconnection

The 2BH1630 is wound for either 380–420 V at 50 Hz or 200 V at 60 Hz. Applying the wrong voltage will cause overheating or failure. Verify the nameplate and supply match before commissioning; reconnection for the other voltage requires opening the terminal box and following the wiring diagram.

Factory Specification Sheet
Process Limits
Do not exceed 140 mbar vacuum or 120 mbar pressure

Operating beyond the maximum differential pressure will overload the motor and may cause overheating or mechanical damage. Use a relief valve or control valve to limit differential pressure in the system, especially during startup or blockage conditions.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the 2BH1630 over the smaller 2BH1009 or 2BH1014?

Choose the 2BH1630 when your process requires up to -140 mbar vacuum or 120 mbar pressure and a 3.0 kW motor. The smaller siblings deliver lower pressure/vacuum and are suited for lower-demand applications. The 2BH1630 also offers higher flow capacity due to its larger impeller and motor.

What are the power supply and starting current requirements for the 2BH1630?

The motor is rated 3.0 kW at 380–420 V/50 Hz or 200 V/60 Hz, drawing 12.0 A. Ensure the supply can handle the starting current, which may be several times the rated current. Use motor protection with the correct trip class and consider a soft starter or star-delta starter if the supply is limited.

Can the 2BH1630 be installed outdoors or in a wet environment?

The motor has IP55 protection, which is dust-tight and protected against water jets, but it is not suitable for immersion or prolonged exposure to heavy rain. For outdoor installation, provide a weatherproof cover and ensure the intake and exhaust are protected from rain and debris. Ambient temperature limits apply per motor data.

What accessories are required but not included with the base blower?

The base delivery includes the blower only. You must provide electrical wiring, motor protection, a mounting base, and piping or ducting. A vacuum relief valve or pressure relief valve is recommended to protect against overpressure. Silencers and filters are optional but may be needed for noise or contamination control.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH1630 IE3 vacuum pump (EN)
Datasheet ·235,6 КБ ·2 pp.
View PDF