Elmo Rietschle 2BH1630
Elmo Rietschle 2BH1630 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -300 mbar, Motor power 2.5 kW, Noise level 64 dB.
The 2BH1630 is a side-channel regenerative blower in the G-BH1 series, driven by a 3.0 kW IE3 motor rated for 50/60 Hz operation. It delivers up to -140 mbar vacuum or 120 mbar positive pressure, distinguishing it from smaller siblings like the 2BH1009 and 2BH1014 by its higher power and flow capacity. It is intended for continuous-duty vacuum or pressure generation in industrial processes requiring oil-free, contactless compression.
Elmo Rietschle G-BH1 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Weight, kg | Max. differential pressure, mbar | Current, A | Protection rating |
|---|---|---|---|---|---|---|
| 2BH1630 Current | 2.5 | 64 | 36 | -160 | 17.1 | IP55 |
| 2BH1009 | — | — | — | — | — | — |
| 2BH1014 | 0.32 | 57 | 11 | -55 | 3.2–6.5 | IP55 |
| 2BH1015 | 1.3 | 64 | 21 | -180 | 8–16 | IP55 |
| 2BH1023 | 1.75 | 69 | 69 | -190 | 10–20 | IP55 |
| 2BH1035 | 2.2 | 64 | 70 | -140 | 14.3–27 | IP55 |
| 2BH1100 | 0.2 | 53 | 10 | -120 | 1.39 Δ / 0.80 Y | IP 55 |
| 2BH1200 | 0.29 | 40 | 57 | -40 | 1.38 0.8 Y | IP55 |
| 2BH1300 | 0.29 | 100 | 51 | -100 | 1.9 | IP 55 |
| 2BH1310 | 0.7 | 56 | 16 | -250 | 3.8 Δ / 2.20 Y | IP55 |
| 2BH1330 | 0.29 | 80 | 51 | — | 1.74 Δ / 1.0 Y | IP55 |
| 2BH1400 | 0.95 | 61 | 16 | -180 | 5.6 | IP55 |
| 2BH1410 | 2 | 65 | 28 | -300 | 6.9 | IP55 |
| 2BH1430 | 1.1 | 64 | 16 | 110 | 4.2 | IP55 |
| 2BH1490 | 0.95 | 61 | 16 | -140 | 4.8 VV | IP55 |
| 2BH1500 | 0.95 | 65 | 21 | -90 | 4.2 | IP55 |
| 2BH1510 | 4 | 71 | 48 | -400 | 7.6–15.2 | IP55 |
| 2BH1530 | 1.6 | 69 | 25 | -90 | 4.7 | IP55 |
| 2BH1590 | 1.3 | 61 | 21 | -190 | 2.75 | IP55 |
| 2BH1600 | 1.75 | 72 | 31 | 130 | 9.9 | IP55 |
| 2BH1610 | 2.5 | 75 | 48 | 160 | 6 | IP55 |
| 2BH1640 | 4.6 | 65 | 65 | -240–260 | 17.1 | IP55 |
| 2BH1690 | 2.5 | 64 | 34 | -200 | 9.9 | IP55 |
| 2BH1800 | 5.8 | 77 | 131 | 260 | 11–22 | IP55 |
| 2BH1810 | 9.9 | 74 | 188 | -460 | 30.8 | IP55 |
| 2BH1830 | 5.8 | 75 | 133 | -160 | 19.4 | IP55 |
| 2BH1900 | 8.6 | 71 | 183 | -190 | 30.8 | IP55 |
| 2BH1910 | 12.6 | 76 | 295 | -220 | 26.4 | IP55 |
| 2BH1930 | 8.6 | 75 | 212 | -80 | 17.6–35.2 | IP55 |
| 2BH1940 | 19.9 | 73 | 303 | -150 | 63.1 | IP55 |
| 2BH1943 | 17.3 | 77 | 330 | -160 | 72.2 UU / 36.1 U | IP55 |
Full specifications
| Max. differential pressure | -160 mbar (50 Hz, order no. 2BH1630-0AK11) 60 Hz, order no. 2BH1630-0AK11: -140 mbar · 50 Hz, order no. 2BH1630-0AK21: -240 mbar · 60 Hz, order no. 2BH1630-0AK21: -230 mbar · 50 Hz, order no. 2BH1630-1AK31: -260 mbar · 60 Hz, order no. 2BH1630-1AK31: -300 mbar |
| Motor power | 2.50 kW (50 Hz, order no. 2BH1630-0AK11) 60 Hz, order no. 2BH1630-0AK11: 3.00 kW · 50 Hz, order no. 2BH1630-0AK21: 3.45 kW · 60 Hz, order no. 2BH1630-0AK21: 4.0 kW · 50 Hz, order no. 2BH1630-1AK31: 4.6 kW · 60 Hz, order no. 2BH1630-1AK31: 5.3 kW |
| Noise level | 64 dB (50 Hz) 60 Hz: 70 dB · 50 Hz, 2-stage: 71 dB · 60 Hz, 2-stage: 74 dB · 50 Hz, 3-stage: 69 dB · 60 Hz, 3-stage: 71 dB |
| Max. differential pressure vacuum mfr | -140 mbar (50 Hz) |
| Max. differential pressure vacuum mfr | -140 mbar (60 Hz) |
| Weight | 36 kg (1-stage) 2-stage: 40 kg · 3-stage: 52 kg |
| Number of stages | 1 (order no. 2BH1630-0AK11) order no. 2BH1630-0AK21: 2 · order no. 2BH1630-1AK31: 3 |
| Current | 9.9 A (50 Hz, order no. 2BH1630-0AK11) 60 Hz, order no. 2BH1630-0AK11: 12.0 / 6.0 A · 50 Hz, order no. 2BH1630-0AK21: 13.3 A · 60 Hz, order no. 2BH1630-0AK21: 15.2 / 7.6 A · 50 Hz, order no. 2BH1630-1AK31: 17.1 A · 60 Hz, order no. 2BH1630-1AK31: 19.6 / 9.8 A |
| Frequency | 50 Hz |
| Power supply | 3~ 50/60 Hz |
| Voltage | 190-210 Δ V (50 Hz, order no. 2BH1630-0AK11) 60 Hz, order no. 2BH1630-0AK11: 190-210 YY / 380-420 Y V · 50 Hz, order no. 2BH1630-0AK16: 220-240 Δ / 380-420 Y V · 60 Hz, order no. 2BH1630-0AK16: 220-240 YY / 440-480 Y V |
| Efficiency class mfr | IE3 |
| Frequency (alt var) mfr | 60 Hz |
| Protection rating | IP55 |
| Sound pressure level mfr | 64 dB(A) (50 Hz) |
| Sound pressure level mfr | 70 dB(A) (60 Hz) |
Description
Construction and series positioning
The 2BH1630 is a single-stage side-channel blower with an impeller directly mounted on the motor shaft. The motor is a 3.0 kW IE3 efficiency class unit, available for 380–420 V at 50 Hz or 200 V at 60 Hz, with IP55 protection and class F insulation. Weighing approximately 36 kg, it is the largest among the listed G-BH1 siblings (2BH1009, 2BH1014, 2BH1015, 2BH1023), which are lower-power variants. The 2BH1630 is chosen when higher pressure or vacuum levels are needed than those smaller models can provide.
Performance and operating envelope
Maximum differential pressure is -140 mbar in vacuum mode and 120 mbar in pressure mode, identical at both 50 and 60 Hz. Sound pressure level is 64 dB(A) at 50 Hz and 70 dB(A) at 60 Hz. The blower is oil-free and contactless, with no internal lubrication or wear parts in the compression chamber. It can operate continuously in either vacuum or pressure mode, but the maximum differential pressure must not be exceeded to avoid motor overload.
Installation and connection
No PDF digests were provided, so specific installation details are not available. Generally, side-channel blowers require rigid mounting, free air intake and exhaust, and protection from ingress of foreign matter. Electrical connection must match the nameplate voltage and frequency; the motor is not dual-voltage without reconnection. Ensure the supply can handle the starting current and that the IP55 enclosure is not compromised during wiring.
Integration & Operating Notes
The 2BH1630 is wound for either 380–420 V at 50 Hz or 200 V at 60 Hz. Applying the wrong voltage will cause overheating or failure. Verify the nameplate and supply match before commissioning; reconnection for the other voltage requires opening the terminal box and following the wiring diagram.
Operating beyond the maximum differential pressure will overload the motor and may cause overheating or mechanical damage. Use a relief valve or control valve to limit differential pressure in the system, especially during startup or blockage conditions.
Selection & Integration Q&A
Choose the 2BH1630 when your process requires up to -140 mbar vacuum or 120 mbar pressure and a 3.0 kW motor. The smaller siblings deliver lower pressure/vacuum and are suited for lower-demand applications. The 2BH1630 also offers higher flow capacity due to its larger impeller and motor.
The motor is rated 3.0 kW at 380–420 V/50 Hz or 200 V/60 Hz, drawing 12.0 A. Ensure the supply can handle the starting current, which may be several times the rated current. Use motor protection with the correct trip class and consider a soft starter or star-delta starter if the supply is limited.
The motor has IP55 protection, which is dust-tight and protected against water jets, but it is not suitable for immersion or prolonged exposure to heavy rain. For outdoor installation, provide a weatherproof cover and ensure the intake and exhaust are protected from rain and debris. Ambient temperature limits apply per motor data.
The base delivery includes the blower only. You must provide electrical wiring, motor protection, a mounting base, and piping or ducting. A vacuum relief valve or pressure relief valve is recommended to protect against overpressure. Silencers and filters are optional but may be needed for noise or contamination control.